Literature DB >> 19268738

Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture.

Hiroshi Doi1, Akiko Maehara, Gary S Mintz, Kenichi Tsujita, Takashi Kubo, Celia Castellanos, Jian Liu, Junqing Yang, Carlos Oviedo, Jiro Aoki, Theresa Franklin-Bond, Neil Dasgupta, Alexandra J Lansky, George D Dangas, Gregg W Stone, Jeffrey W Moses, Roxana Mehran, Martin B Leon.   

Abstract

We sought to examine the intravascular ultrasound (IVUS) findings of stent fracture. Stent fracture has been implicated as a cause of drug-eluting stent failure. IVUS is more likely to identify mechanisms of stent failure -- including stent fracture -- than angiography. Twenty stent fractures diagnosed by IVUS in 17 patients were evaluated. Eighteen stent fractures (90%) occurred in sirolimus-eluting Cypher stents, and 2 stent fractures (10%) occurred in bare metal stents, but none occurred in paclitaxel-eluting Taxus stents. Half of the stent fractures presented < or =1 year after implantation, and (1/2) presented >1 year after implantation. IVUS analysis showed that 9 stent fractures were complete (45%) and 11 were partial (55%); 10 (50%) were adjacent to stent metal overlap; and 5 occurred in a coronary aneurysm accompanied by malapposition (all Cypher stents) despite the absence of an aneurysm at index stenting. Compared with 60 matched control segments in patients without stent fracture, but with similar clinical events, the stent fracture group had longer stent segments (45.2 +/- 23.0 vs 28.5 +/- 14.9 mm, p = 0.003). Comparing stent fractures associated with an aneurysm (n = 5) with those that did not occur in association with an aneurysm (n = 15) showed that complete stent fracture was more frequent (100% vs 27%, p = 0.008), and all presented >1 year after index stenting (vs 33%, p = 0.03). In conclusion, IVUS is helpful to identify stent fracture as a cause of stent failure and to understand possible mechanisms of stent fracture such as aneurysm formation.

Entities:  

Mesh:

Year:  2009        PMID: 19268738     DOI: 10.1016/j.amjcard.2008.11.051

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  20 in total

Review 1.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

2.  Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: a multislice computed tomography study.

Authors:  Tsuyoshi Ito; Masashi Kimura; Mariko Ehara; Mitsuyasu Terashima; Kenya Nasu; Yoshihisa Kinoshita; Maoto Habara; Etsuo Tsuchikane; Takahiko Suzuki
Journal:  Eur Radiol       Date:  2014-02-25       Impact factor: 5.315

3.  Recurrent episode of very late stent thrombosis in a patient who underwent percutaneous coronary intervention with sirolimus-eluting stent: Same or different mechanism?

Authors:  Soon Yong Suh; Woong Chol Kang; Taehoon Ahn
Journal:  J Cardiol Cases       Date:  2011-12-06

Review 4.  Pathology of Endovascular Stents.

Authors:  Kenta Nakamura; John H Keating; Elazer Reuven Edelman
Journal:  Interv Cardiol Clin       Date:  2016-05-19

5.  Stent fracture at the proximal shaft of the left main stem.

Authors:  Jae Ho Lee; Suk Min Seo; Eun Oh Kim; Hyo Jun Ahn; Yang Won Lee; Yul-Hee Cho; Inwoon Baek; You Suk Oh; Jihyun Yu; Ki-Bae Seung
Journal:  Korean Circ J       Date:  2011-12-31       Impact factor: 3.243

6.  Two cases of immediate stent fracture after zotarolimus-eluting stent implantation.

Authors:  Pil Hyung Lee; Seung-Whan Lee; Jong-Young Lee; Young-Hak Kim; Cheol Whan Lee; Duk-Woo Park; Seong-Wook Park; Seung-Jung Park
Journal:  Korean Circ J       Date:  2015-01-26       Impact factor: 3.243

7.  Stent fracture and occlusion after treatment of symptomatic vertebral artery ostium stenosis with a self-expanding device. A case report.

Authors:  Jun Lu; Jiachun Liu; Daming Wang; Shuo Wang
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

8.  Impending rupture of saphenous vein graft aneurysm with floating fractured bare metal stent treated by coil embolization and covered stent implantation.

Authors:  Atsuko Kodama; Tairo Kurita; Osamu Kato; Takahiko Suzuki
Journal:  Heart Vessels       Date:  2016-01-27       Impact factor: 2.037

9.  Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry.

Authors:  Kyung Woo Park; Jin Joo Park; In-Ho Chae; Jae-Bin Seo; Han-Mo Yang; Hae-Young Lee; Hyun-Jae Kang; Young-Seok Cho; Tae-Jin Yeon; Woo-Young Chung; Bon-Kwon Koo; Dong-Ju Choi; Byung-Hee Oh; Young-Bae Park; Hyo-Soo Kim
Journal:  J Korean Med Sci       Date:  2010-12-22       Impact factor: 2.153

10.  Stent fracture: how frequently is it recognized?

Authors:  Mohammed Khalil Mohsen; Awad Alqahtani; Jassim Al Suwaidi
Journal:  Heart Views       Date:  2013-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.