A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation.

Jeffrey J Popma1, Klaus Tiroch, Alexandra Almonacid, Sidney Cohen, David E Kandzari, Martin B Leon.   

Abstract

Repetitive mechanical forces within the coronary artery may result in stent fracture after stent implantation, particularly in patients with complex coronary disease. This study sought to estimate the incidence of Cypher stent fracture in patients with moderately severe coronary disease and to identify the angiographic predictors of fractures in patients identified in a global Cypher fracture registry. Stent fracture analysis was performed in 305 patients treated with the Cypher stent in SIRIUS and in 39 patients with stent fractures reported in the Cypher fracture registry. Fractures were classified as isolated strut fractures (type 1, single-strut fracture; type 2, incomplete transverse fracture) and stent fracture (type 3, complete transverse fracture without displacement; type 4, transverse fracture with displacement). Isolated strut fractures were identified in 4 patients (1.3%) enrolled in SIRIUS (type 1 1.0%, type 2 0.3%); no stent fractures were identified. In 39 patients with 44 clinically reported Cypher fractures, isolated strut fractures were present in 15.4% (all type 2) and stent fractures were found in 84.6% (type 3 38.4%, type 4 46.2%). Compared with patients in SIRIUS, patients with clinically reported fractures had much greater lesion complexity, including extensive calcification, angulation > or =45 degrees , lesion length > or =20 mm, proximal vessel tortuosity, total occlusions, and an ostial location. Clinically reported fractures were associated with a high rate of repeat target lesion revascularization (52.6%). In conclusion, stent fracture after Cypher stent placement occurs more often in patients with "ultra"-complex coronary anatomy, but is an uncommon event in patients treated with mild to moderate lesion complexity.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19327417     DOI: 10.1016/j.amjcard.2008.12.022

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  14 in total

Review 1.  Are we aware of stent fracture?

Authors:  R D Acar; M Bulut; M Akcakoyun
Journal:  Herz       Date:  2013-10-25       Impact factor: 1.443

2.  Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: a multislice computed tomography study.

Authors:  Tsuyoshi Ito; Masashi Kimura; Mariko Ehara; Mitsuyasu Terashima; Kenya Nasu; Yoshihisa Kinoshita; Maoto Habara; Etsuo Tsuchikane; Takahiko Suzuki
Journal:  Eur Radiol       Date:  2014-02-25       Impact factor: 5.315

3.  Application of a new three-dimensional method for the measurement of coronary stent angulation and comparison with conventional methods.

Authors:  Huaiyu Qiao; Luyue Gai; Minhan Wang; Bin He; Shuoyang Zhang; Xia Yang; Qinhua Jin; Zhiwei Guan
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-21       Impact factor: 2.357

4.  Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section.

Authors:  Kartik V Bulusu; Michael W Plesniak
Journal:  J Vis Exp       Date:  2016-07-19       Impact factor: 1.355

5.  Coronary stent thrombosis: what have we learned?

Authors:  Carlos Collet; Yohei Sotomi; Rafael Cavalcante; Pannipa Suwannasom; Erhan Tenekecioglu; Yoshinobu Onuma; Patrick W Serruys
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

6.  Structural Mechanics Predictions Relating to Clinical Coronary Stent Fracture in a 5 Year Period in FDA MAUDE Database.

Authors:  Kay D Everett; Claire Conway; Gerard J Desany; Brian L Baker; Gilwoo Choi; Charles A Taylor; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2015-10-14       Impact factor: 3.934

7.  Two cases of immediate stent fracture after zotarolimus-eluting stent implantation.

Authors:  Pil Hyung Lee; Seung-Whan Lee; Jong-Young Lee; Young-Hak Kim; Cheol Whan Lee; Duk-Woo Park; Seong-Wook Park; Seung-Jung Park
Journal:  Korean Circ J       Date:  2015-01-26       Impact factor: 3.243

8.  Validating Fatigue Safety Factor Calculation Methods for Cardiovascular Stents.

Authors: 
Journal:  J Biomech Eng       Date:  2018-06-01       Impact factor: 2.097

9.  Pathology of second-generation everolimus-eluting stents versus first-generation sirolimus- and paclitaxel-eluting stents in humans.

Authors:  Fumiyuki Otsuka; Marc Vorpahl; Masataka Nakano; Jason Foerst; John B Newell; Kenichi Sakakura; Robert Kutys; Elena Ladich; Aloke V Finn; Frank D Kolodgie; Renu Virmani
Journal:  Circulation       Date:  2013-10-25       Impact factor: 29.690

10.  Angiographic characteristics of femoropopliteal in-stent restenosis: association with long-term outcomes after endovascular intervention.

Authors:  Ehrin J Armstrong; Satinder Singh; Gagan D Singh; Khung-Keong Yeo; Shaan Ludder; Gregory Westin; David Anderson; David L Dawson; William C Pevec; John R Laird
Journal:  Catheter Cardiovasc Interv       Date:  2013-06-03       Impact factor: 2.692