Literature DB >> 24531917

Needle deflection estimation: prostate brachytherapy phantom experiments.

Hossein Sadjadi1,2, Keyvan Hashtrudi-Zaad3, Gabor Fichtinger4.   

Abstract

PURPOSE: The performance of a fusion-based needle deflection estimation method was experimentally evaluated using prostate brachytherapy phantoms. The accuracy of the needle deflection estimation was determined. The robustness of the approach with variations in needle insertion speed and soft tissue biomechanical properties was investigated.
METHODS: A needle deflection estimation method was developed to determine the amount of needle bending during insertion into deformable tissue by combining a kinematic deflection model with measurements taken from two electromagnetic trackers placed at the tip and the base of the needle. Experimental verification of this method for use in prostate brachytherapy needle insertion procedures was performed. A total of 21 beveled tip, 18 ga, 200 mm needles were manually inserted at various speeds through a template and toward different targets distributed within 3 soft tissue mimicking polyvinyl chloride prostate phantoms of varying stiffness. The tracked positions of both the needle tip and base were recorded, and Kalman filters were applied to fuse the sensory information. The estimation results were validated using ground truth obtained from fluoroscopy images.
RESULTS: The manual insertion speed ranged from 8 to 34 mm/s, needle deflection ranged from 5 to 8 mm at an insertion depth of 76 mm, and the elastic modulus of the soft tissue ranged from 50 to 150 kPa. The accuracy and robustness of the estimation method were verified within these ranges. When compared to purely model-based estimation, we observed a reduction in needle tip position estimation error by [Formula: see text] % (mean [Formula: see text] SD) and the cumulative deflection error by [Formula: see text] %.
CONCLUSIONS: Fusion of electromagnetic sensors demonstrated significant improvement in estimating needle deflection compared to model-based methods. The method has potential clinical applicability in the guidance of needle placement medical interventions, particularly prostate brachytherapy.

Entities:  

Keywords:  Brachytherapy; Electromagnetic tracking; Kalman filter; Needle deflection estimation; Sensor fusion; Surgical navigation

Mesh:

Year:  2014        PMID: 24531917     DOI: 10.1007/s11548-014-0985-0

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  31 in total

1.  Kinematic state estimation and motion planning for stochastic nonholonomic systems using the exponential map.

Authors:  Wooram Park; Yan Liu; Yu Zhou; Matthew Moses; Gregory S Chirikjian
Journal:  Robotica       Date:  2008-04-11       Impact factor: 2.088

2.  Brachytherapy needle deflection evaluation and correction.

Authors:  Gang Wan; Zhouping Wei; Lori Gardi; Donal B Downey; Aaron Fenster
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

Review 3.  Needle insertion into soft tissue: a survey.

Authors:  Niki Abolhassani; Rajni Patel; Mehrdad Moallem
Journal:  Med Eng Phys       Date:  2006-08-28       Impact factor: 2.242

4.  Development of a tapping device: a new needle insertion method for prostate brachytherapy.

Authors:  V Lagerburg; M A Moerland; M K Konings; R E van de Vosse; J J W Lagendijk; J J Battermann
Journal:  Phys Med Biol       Date:  2006-01-25       Impact factor: 3.609

5.  Effects of different insertion methods on reducing needle deflection.

Authors:  Niki Abolhassani; Rajni Patel; Farzam Ayazi
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

6.  Multisensor data fusion in an integrated tracking system for endoscopic surgery.

Authors:  Hongliang Ren; Denis Rank; Martin Merdes; Jan Stallkamp; Peter Kazanzides
Journal:  IEEE Trans Inf Technol Biomed       Date:  2011-08-08

7.  Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.

Authors:  Hossein Sadjadi; Keyvan Hashtrudi-Zaad; Gabor Fichtinger
Journal:  IEEE Trans Biomed Eng       Date:  2013-05-13       Impact factor: 4.538

8.  A New Scheme for Curved Needle Segmentation in Three-Dimensional Ultrasound Images.

Authors:  Mohammad Aboofazeli; Purang Abolmaesumi; Parvin Mousavi; Gabor Fichtinger
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-01

9.  Behavior of tip-steerable needles in ex vivo and in vivo tissue.

Authors:  Ann Majewicz; Steven P Marra; Mark G van Vledder; MingDe Lin; Michael A Choti; Danny Y Song; Allison M Okamura
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-13       Impact factor: 4.538

10.  A realistic deformable prostate phantom for multimodal imaging and needle-insertion procedures.

Authors:  Nikolai Hungr; Jean-Alexandre Long; Vincent Beix; Jocelyne Troccaz
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

View more
  4 in total

1.  Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy.

Authors:  Elodie Lugez; Hossein Sadjadi; Chandra P Joshi; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-18       Impact factor: 2.924

2.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

3.  Needle deflection and tissue sampling length in needle biopsy.

Authors:  Annie D R Li; Jeffrey Plott; Lei Chen; Jeffrey S Montgomery; Albert Shih
Journal:  J Mech Behav Biomed Mater       Date:  2020-01-11

4.  Axially rigid steerable needle with compliant active tip control.

Authors:  M de Vries; J Sikorski; S Misra; J J van den Dobbelsteen
Journal:  PLoS One       Date:  2021-12-16       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.