Literature DB >> 21827975

Multisensor data fusion in an integrated tracking system for endoscopic surgery.

Hongliang Ren1, Denis Rank, Martin Merdes, Jan Stallkamp, Peter Kazanzides.   

Abstract

Surgical planning and navigation systems are vital for minimally invasive endoscopic surgeries but it is challenging to track the position and orientation of intrabody surgical instruments in these procedures. In order to address this problem, we propose a tracking system including multiple-sensor integration and data fusion. The proposed tracking approach is free of the constraints of line-of-sight, less subject to environmental distortion, and with higher update rate. By incorporating electromagnetic and inertial sensors, the system yields continuous 6-DOF information. Based on a system dynamic model and estimation theories, a new multisensor fusion algorithm, cascade orientation and position-estimation algorithm, is proposed for the integrated tracking device. The experimental results show that the proposed algorithms achieve accurate orientation and position tracking with robustness.

Mesh:

Year:  2011        PMID: 21827975     DOI: 10.1109/TITB.2011.2164088

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  6 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  A cost-effective surgical navigation solution for periacetabular osteotomy (PAO) surgery.

Authors:  Silvio Pflugi; Li Liu; Timo M Ecker; Steffen Schumann; Jennifer Larissa Cullmann; Klaus Siebenrock; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-08-02       Impact factor: 2.924

3.  SCADE: Simultaneous Sensor Calibration and Deformation Estimation of FBG-Equipped Unmodeled Continuum Manipulators.

Authors:  Farshid Alambeigi; Sahba Aghajani Pedram; Jason L Speyer; Jacob Rosen; Iulian Iordachita; Russell H Taylor; Mehran Armand
Journal:  IEEE Trans Robot       Date:  2019-10-29       Impact factor: 5.567

4.  Needle deflection estimation: prostate brachytherapy phantom experiments.

Authors:  Hossein Sadjadi; Keyvan Hashtrudi-Zaad; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-17       Impact factor: 2.924

5.  Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

Authors:  Hyung-Chul Lee; Chul-Woo Jung; Hee Chan Kim
Journal:  PLoS One       Date:  2017-11-03       Impact factor: 3.240

6.  An adaptive 6-DOF tracking method by hybrid sensing for ultrasonic endoscopes.

Authors:  Chengyang Du; Xiaodong Chen; Yi Wang; Junwei Li; Daoyin Yu
Journal:  Sensors (Basel)       Date:  2014-06-06       Impact factor: 3.576

  6 in total