Literature DB >> 23674421

Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.

Hossein Sadjadi, Keyvan Hashtrudi-Zaad, Gabor Fichtinger.   

Abstract

We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.

Entities:  

Mesh:

Year:  2013        PMID: 23674421     DOI: 10.1109/TBME.2013.2262658

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  SCADE: Simultaneous Sensor Calibration and Deformation Estimation of FBG-Equipped Unmodeled Continuum Manipulators.

Authors:  Farshid Alambeigi; Sahba Aghajani Pedram; Jason L Speyer; Jacob Rosen; Iulian Iordachita; Russell H Taylor; Mehran Armand
Journal:  IEEE Trans Robot       Date:  2019-10-29       Impact factor: 5.567

3.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

4.  Needle deflection estimation: prostate brachytherapy phantom experiments.

Authors:  Hossein Sadjadi; Keyvan Hashtrudi-Zaad; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-02-17       Impact factor: 2.924

5.  STEERABLE NEEDLE TRAJECTORY FOLLOWING IN THE LUNG: TORSIONAL DEADBAND COMPENSATION AND FULL POSE ESTIMATION WITH 5DOF FEEDBACK FOR NEEDLES PASSING THROUGH FLEXIBLE ENDOSCOPES.

Authors:  Tayfun Efe Ertop; Maxwell Emerson; Margaret Rox; Josephine Granna; Fabien Maldonado; Erin Gillaspie; Michael Lester; Alan Kuntz; Caleb Rucker; Mengyu Fu; Janine Hoelscher; Inbar Fried; Ron Alterovitz; Robert Webster
Journal:  Proc ASME Dyn Syst Control Conf       Date:  2020-10

6.  Modular robotic platform for precision neurosurgery with a bio-inspired needle: System overview and first in-vivo deployment.

Authors:  Riccardo Secoli; Eloise Matheson; Marlene Pinzi; Stefano Galvan; Abdulhamit Donder; Thomas Watts; Marco Riva; Davide Danilo Zani; Lorenzo Bello; Ferdinando Rodriguez Y Baena
Journal:  PLoS One       Date:  2022-10-19       Impact factor: 3.752

7.  Kalman filter-based EM-optical sensor fusion for needle deflection estimation.

Authors:  Baichuan Jiang; Wenpeng Gao; Daniel Kacher; Erez Nevo; Barry Fetics; Thomas C Lee; Jagadeesan Jayender
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-02-07       Impact factor: 2.924

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.