Literature DB >> 16485428

Monte carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom.

Richard Taschereau1, Patrick L Chow, Arion F Chatziioannou.   

Abstract

The purpose of this work was to calculate radiation dose and its organ distribution in a realistic mouse phantom from micro-computed tomography (microCT) imaging protocols. CT dose was calculated using GATE and a voxelized, realistic phantom. The x-ray photon energy spectra used in simulations were precalculated with GATE and validated against previously published data. The number of photons required per simulated experiments was determined by direct exposure measurements. Simulated experiments were performed for three types of beams and two types of mouse beds. Dose-volume histograms and dose percentiles were calculated for each organ. For a typical microCT screening examination with a reconstruction voxel size of 200 microm, the average whole body dose varied from 80 mGy (at 80 kVp) to 160 mGy (at 50 kVp), showing a strong dependence on beam hardness. The average dose to the bone marrow is close to the soft tissue average. However, due to dose nonuniformity and higher radiation sensitivity, 5% of the marrow would receive an effective dose about four times higher than the average. If CT is performed longitudinally, a significant radiation dose can be given. The total absorbed radiation dose is a function of milliamperes-second, beam hardness, and desired image quality (resolution, noise and contrast). To reduce dose, it would be advisable to use the hardest beam possible while maintaining an acceptable contrast in the image.

Entities:  

Mesh:

Year:  2006        PMID: 16485428      PMCID: PMC3005289          DOI: 10.1118/1.2148333

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Low-dose whole-body irradiation (LD-WBI) changes protein expression of mouse thymocytes: effect of a LD-WBI-enhanced protein RIP10 on cell proliferation and spontaneous or radiation-induced thymocyte apoptosis.

Authors:  S L Chen; L Cai; Q Y Meng; S Xu; H Wan; S Z Liu
Journal:  Toxicol Sci       Date:  2000-05       Impact factor: 4.849

2.  Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

Authors:  Y Liu; H Liu; Y Wang; G Wang
Journal:  Med Phys       Date:  2001-07       Impact factor: 4.071

Review 3.  On radiation hormesis expressed in the immune system.

Authors:  Shu-Zheng Liu
Journal:  Crit Rev Toxicol       Date:  2003       Impact factor: 5.635

4.  Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis.

Authors:  M Ding; A Odgaard; I Hvid
Journal:  J Bone Joint Surg Br       Date:  2003-08

5.  Attenuation correction for small animal PET tomographs.

Authors:  Patrick L Chow; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

6.  Whole-body skeletal imaging in mice utilizing microPET: optimization of reproducibility and applications in animal models of bone disease.

Authors:  Frank Berger; Yu-Po Lee; Andreas M Loening; Arion Chatziioannou; Stephen J Freedland; Richard Leahy; Jay R Lieberman; Arie S Belldegrun; Charles L Sawyers; Sanjiv S Gambhir
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-09       Impact factor: 9.236

7.  Effects of low dose radiation on signal transduction of neurons in mouse hypothalamus.

Authors:  H Wan; S L Gong; S Z Liu
Journal:  Biomed Environ Sci       Date:  2001-09       Impact factor: 3.118

8.  Low doses of radiation increase the latency of spontaneous lymphomas and spinal osteosarcomas in cancer-prone, radiation-sensitive Trp53 heterozygous mice.

Authors:  R E J Mitchel; J S Jackson; D P Morrison; S M Carlisle
Journal:  Radiat Res       Date:  2003-03       Impact factor: 2.841

9.  Murine S factors for liver, spleen, and kidney.

Authors:  Katherine S Kolbert; Timotheus Watson; Cornelia Matei; Su Xu; Jason A Koutcher; George Sgouros
Journal:  J Nucl Med       Date:  2003-05       Impact factor: 10.057

10.  Radioprotection of Swiss albino mice by plant extract Mentha piperita (Linn.).

Authors:  R M Samarth; Ashok Kumar
Journal:  J Radiat Res       Date:  2003-06       Impact factor: 2.724

View more
  28 in total

1.  Scattered Dose Calculations and Measurements in a Life-Like Mouse Phantom.

Authors:  David Welch; Leah Turner; Michael Speiser; Gerhard Randers-Pehrson; David J Brenner
Journal:  Radiat Res       Date:  2017-01-31       Impact factor: 2.841

2.  Compressed voxels for high-resolution phantom simulations in GATE.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2008 Jan-Feb       Impact factor: 3.488

Review 3.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

Review 4.  Imaging technologies and basic considerations for welfare of laboratory rodents.

Authors:  Jordi L Tremoleda; Jane Sosabowski
Journal:  Lab Anim (NY)       Date:  2015-03       Impact factor: 12.625

5.  Dual tracer imaging of SPECT and PET probes in living mice using a sequential protocol.

Authors:  Sarah E Chapman; Justin M Diener; Todd A Sasser; Carlos Correcher; Antonio J González; Tony Van Avermaete; W Matthew Leevy
Journal:  Am J Nucl Med Mol Imaging       Date:  2012-10-15

6.  Automated analysis of small animal PET studies through deformable registration to an atlas.

Authors:  Daniel F Gutierrez; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-07-21       Impact factor: 9.236

7.  Evaluation of the Genisys4, a bench-top preclinical PET scanner.

Authors:  Ken Herrmann; Magnus Dahlbom; David Nathanson; Liu Wei; Caius Radu; Arion Chatziioannou; Johannes Czernin
Journal:  J Nucl Med       Date:  2013-04-29       Impact factor: 10.057

8.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

9.  Characterization of osteolytic, osteoblastic, and mixed lesions in a prostate cancer mouse model using 18F-FDG and 18F-fluoride PET/CT.

Authors:  Wellington K Hsu; Mandeep S Virk; Brian T Feeley; David B Stout; Arion F Chatziioannou; Jay R Lieberman
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

10.  Small animal absorbed radiation dose from serial micro-computed tomography imaging.

Authors:  Stephanie K Carlson; Kelly L Classic; Claire E Bender; Stephen J Russell
Journal:  Mol Imaging Biol       Date:  2007 Mar-Apr       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.