Literature DB >> 28539296

[Establishment of a rabbit model of small diameter vascular graft replacement].

Jia-Qing Zhang1, Kun-Tang Chen, Fu-Wei Zhang, Shao-Bin Li, Yuan-Zhou Wu, Jing Feng, Wu-Jun Wang, Yu-Sheng Yan.   

Abstract

OBJECTIVE: To establish an rabbit model that mimics the hemodynamics of the bypass graft after coronary artery bypass surgery.
METHODS: Sixteen New Zealand rabbits were randomly divided into two groups for abdominal aortic artery replacement using a 3-cm-long ePTFE graft with an inner diameter 4 mm through an incision at 1/3 from the middle to the lower part of the abdomen (group A) or in the lower abdomen (group B). The general conditions of the rabbits, operative time, number of collateral vessels that needed to be ligated, rate of massive intraoperative bleeding, fluctuation of vascular anastomosis after surgery, patency rate of the graft on day 7 after the operation were compared between the two groups.
RESULTS: The two groups of rabbits had similar body weight, diameter of the abdominal aortic artery, intraoperative bleeding rate and occlusion rate of the vascular graft at 7 days after the procedure. The operative time was longer in group A, but the difference was not statistically significant. In group A, the number of the vascular branches that needed to be ligated was smaller and the rate normal femoral artery pulsation was higher than those in group B.
CONCLUSION: It is feasible to establish models of small diameter vascular graft replacement in rabbits, and the patency rate of the graft can be monitored by observation of the general condition and ultrasound examination of the rabbits.

Entities:  

Mesh:

Year:  2017        PMID: 28539296      PMCID: PMC6780461     

Source DB:  PubMed          Journal:  Nan Fang Yi Ke Da Xue Xue Bao        ISSN: 1673-4254


  24 in total

1.  Remodeling of small intramyocardial coronary arteries distal to total occlusions after myocardial infarction in pigs.

Authors:  Huiqiang Zhao; Hui Chen; Hongwei Li; Dongbao Li; Shouli Wang; Yaling Han
Journal:  Coron Artery Dis       Date:  2013-09       Impact factor: 1.439

2.  Ferric Chloride-induced Thrombosis Mouse Model on Carotid Artery and Mesentery Vessel.

Authors:  Thomas Bonnard; Christoph E Hagemeyer
Journal:  J Vis Exp       Date:  2015-06-29       Impact factor: 1.355

3.  Well-organized neointima of large-pore poly(L-lactic acid) vascular graft coated with poly(L-lactic-co-ε-caprolactone) prevents calcific deposition compared to small-pore electrospun poly(L-lactic acid) graft in a mouse aortic implantation model.

Authors:  Shuhei Tara; Hirotsugu Kurobe; Kevin A Rocco; Mark W Maxfield; Cameron A Best; Tai Yi; Yuji Naito; Christopher K Breuer; Toshiharu Shinoka
Journal:  Atherosclerosis       Date:  2014-10-17       Impact factor: 5.162

4.  Anatomical and functional imaging of myocardial infarction in mice using micro-CT and eXIA 160 contrast agent.

Authors:  Jeffrey R Ashton; Nicholas Befera; Darin Clark; Yi Qi; Lan Mao; Howard A Rockman; G Allan Johnson; Cristian T Badea
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

5.  The minipig as a new model for the evaluation of doxorubicin-induced chronic toxicity.

Authors:  Rosa Anna Manno; Andrea Grassetti; Germano Oberto; Abraham Nyska; Yuval Ramot
Journal:  J Appl Toxicol       Date:  2015-11-27       Impact factor: 3.446

6.  Porcine carotid artery replacement with biodegradable electrospun poly-e-caprolactone vascular prosthesis.

Authors:  Wojciech Mrówczyński; Damiano Mugnai; Sarra de Valence; Jean-Christophe Tille; Ebrahim Khabiri; Mustafa Cikirikcioglu; Michael Möller; Beat H Walpoth
Journal:  J Vasc Surg       Date:  2013-05-24       Impact factor: 4.268

7.  Blood outgrowth endothelial cells alter remodeling of completely biological engineered grafts implanted into the sheep femoral artery.

Authors:  Lee A Meier; Zeeshan H Syedain; Matthew T Lahti; Sandra S Johnson; Minna H Chen; Robert P Hebbel; Robert T Tranquillo
Journal:  J Cardiovasc Transl Res       Date:  2014-01-16       Impact factor: 4.132

Review 8.  Animal models for vascular tissue-engineering.

Authors:  Daniel D Swartz; Stelios T Andreadis
Journal:  Curr Opin Biotechnol       Date:  2013-06-13       Impact factor: 9.740

9.  Intracoronary delivery of autologous cardiac stem cells improves cardiac function in a porcine model of chronic ischemic cardiomyopathy.

Authors:  Roberto Bolli; Xian-Liang Tang; Santosh K Sanganalmath; Ornella Rimoldi; Federico Mosna; Ahmed Abdel-Latif; Hani Jneid; Marcello Rota; Annarosa Leri; Jan Kajstura
Journal:  Circulation       Date:  2013-06-11       Impact factor: 29.690

10.  Imaging RAGE expression in atherosclerotic plaques in hyperlipidemic pigs.

Authors:  Lynne L Johnson; Yared Tekabe; Maria Kollaros; George Eng; Ketan Bhatia; Chong Li; Christian G Krueger; Dhanansayan Shanmuganayagam; Ann Marie Schmidt
Journal:  EJNMMI Res       Date:  2014-06-11       Impact factor: 3.138

View more
  1 in total

1.  Construction of digital three-dimensional reconstruction model of rabbit vascular network.

Authors:  Qinghong Song; Yan Zhang
Journal:  Saudi J Biol Sci       Date:  2019-09-24       Impact factor: 4.219

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.