Literature DB >> 27694701

Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT.

Qian Cao1, Wojciech Zbijewski, Alejandro Sisniega, John Yorkston, Jeffrey H Siewerdsen, J Webster Stayman.   

Abstract

Application of model-based iterative reconstruction (MBIR) to high resolution cone-beam CT (CBCT) is computationally challenging because of the very fine discretization (voxel size  <100 µm) of the reconstructed volume. Moreover, standard MBIR techniques require that the complete transaxial support for the acquired projections is reconstructed, thus precluding acceleration by restricting the reconstruction to a region-of-interest. To reduce the computational burden of high resolution MBIR, we propose a multiresolution penalized-weighted least squares (PWLS) algorithm, where the volume is parameterized as a union of fine and coarse voxel grids as well as selective binning of detector pixels. We introduce a penalty function designed to regularize across the boundaries between the two grids. The algorithm was evaluated in simulation studies emulating an extremity CBCT system and in a physical study on a test-bench. Artifacts arising from the mismatched discretization of the fine and coarse sub-volumes were investigated. The fine grid region was parameterized using 0.15 mm voxels and the voxel size in the coarse grid region was varied by changing a downsampling factor. No significant artifacts were found in either of the regions for downsampling factors of up to 4×. For a typical extremities CBCT volume size, this downsampling corresponds to an acceleration of the reconstruction that is more than five times faster than a brute force solution that applies fine voxel parameterization to the entire volume. For certain configurations of the coarse and fine grid regions, in particular when the boundary between the regions does not cross high attenuation gradients, downsampling factors as high as 10×  can be used without introducing artifacts, yielding a ~50×  speedup in PWLS. The proposed multiresolution algorithm significantly reduces the computational burden of high resolution iterative CBCT reconstruction and can be extended to other applications of MBIR where computationally expensive, high-fidelity forward models are applied only to a sub-region of the field-of-view.

Entities:  

Mesh:

Year:  2016        PMID: 27694701      PMCID: PMC5061055          DOI: 10.1088/0031-9155/61/20/7263

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality.

Authors:  Avice O'Connell; David L Conover; Yan Zhang; Posy Seifert; Wende Logan-Young; Chuen-Fu Linda Lin; Lawrence Sahler; Ruola Ning
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  Penalized-likelihood region-of-interest CT reconstruction by local object supersampling.

Authors:  Benoit Hamelin; Yves Goussard; Jean-Pierre Dussault
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

4.  Technical assessment of a cone-beam CT scanner for otolaryngology imaging: image quality, dose, and technique protocols.

Authors:  J Xu; D D Reh; J P Carey; M Mahesh; J H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

Review 5.  Cone-beam imaging: applications in ENT.

Authors:  C Hodez; C Griffaton-Taillandier; I Bensimon
Journal:  Eur Ann Otorhinolaryngol Head Neck Dis       Date:  2011-04-02       Impact factor: 2.080

6.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

7.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

8.  Metal artifact reduction in computed tomography using local models in an image block-iterative scheme.

Authors:  Katrien Van Slambrouck; Johan Nuyts
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

Review 9.  Clinical imaging of bone microarchitecture with HR-pQCT.

Authors:  Kyle K Nishiyama; Elizabeth Shane
Journal:  Curr Osteoporos Rep       Date:  2013-06       Impact factor: 5.096

Review 10.  Microcomputed tomography: approaches and applications in bioengineering.

Authors:  Joel D Boerckel; Devon E Mason; Anna M McDermott; Eben Alsberg
Journal:  Stem Cell Res Ther       Date:  2014-12-29       Impact factor: 6.832

View more
  10 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

3.  Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head.

Authors:  Hao Dang; J Webster Stayman; Alejandro Sisniega; Wojciech Zbijewski; Jennifer Xu; Xiaohui Wang; David H Foos; Nafi Aygun; Vassilis E Koliatsos; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-12-29       Impact factor: 3.609

4.  Model-based three-material decomposition in dual-energy CT using the volume conservation constraint.

Authors:  Stephen Z Liu; Matthew Tivnan; Greg M Osgood; Jeffrey H Siewerdsen; J Webster Stayman; Wojciech Zbijewski
Journal:  Phys Med Biol       Date:  2022-07-08       Impact factor: 4.174

5.  Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept.

Authors:  Katsuyuki Taguchi; Thomas J Sauer; W Paul Segars; Eric C Frey; Jingyan Xu; Eleni Liapi; J Webster Stayman; Kelvin Hong; Ferdinand K Hui; Mathias Unberath; Yong Du
Journal:  Med Phys       Date:  2020-10-22       Impact factor: 4.071

6.  Model-based dual-energy tomographic image reconstruction of objects containing known metal components.

Authors:  Stephen Z Liu; Qian Cao; Matthew Tivnan; Steven Tilley Ii; Jeffrey H Siewerdsen; J Webster Stayman; Wojciech Zbijewski
Journal:  Phys Med Biol       Date:  2020-12-22       Impact factor: 4.174

7.  Optimization of a secondary VOI protocol for lung imaging in a clinical CT scanner.

Authors:  Thomas C Larsen; Vissagan Gopalakrishnan; Jianhua Yao; Catherine P Nguyen; Marcus Y Chen; Joel Moss; Han Wen
Journal:  J Appl Clin Med Phys       Date:  2018-05-21       Impact factor: 2.102

8.  Three-dimensional mapping of the joint space for the diagnosis of knee osteoarthritis based on high resolution computed tomography: Comparison with radiographic, outerbridge, and meniscal classifications.

Authors:  Houda Mezlini-Gharsallah; Rabaa Youssef; Stéphanie Uk; Jean D Laredo; Christine Chappard
Journal:  J Orthop Res       Date:  2018-04-27       Impact factor: 3.494

9.  Halve the dose while maintaining image quality in paediatric Cone Beam CT.

Authors:  Anne Caroline Oenning; Ruben Pauwels; Andreas Stratis; Karla De Faria Vasconcelos; Elisabeth Tijskens; Annelore De Grauwe; Reinhilde Jacobs; Benjamin Salmon
Journal:  Sci Rep       Date:  2019-04-02       Impact factor: 4.379

10.  Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique.

Authors:  Shigeru Suzuki; Yoshiaki Katada; Tomoko Takayanagi; Haruto Sugawara; Takuya Ishikawa; Yuzo Yamamoto; Hiroo Wada
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.