A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

Scott S Hsieh1, David A Chesler2, Dominik Fleischmann1, Norbert J Pelc3.   

Abstract

PURPOSE: To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object.
METHODS: The authors examined the task of estimating the density of a circular lesion in a cross section. Raw data were simulated by forward projection of existing images and numerical phantoms. To assess an upper bound on the achievable dose reduction by any algorithm, the authors assume that both the background and the shape of the lesion are completely known. Under these conditions, the best possible estimate of the density can be determined by solving a weighted least squares problem directly in the raw data domain. Any possible reconstruction algorithm that does not use prior knowledge or make assumptions about the object, including filtered backprojection (FBP) or iterative reconstruction methods with this constraint, must be no better than this least squares solution. The authors simulated 10,000 sets of noisy data and compared the variance in density from the least squares solution with those from FBP. Density was estimated from FBP images using either averaging within a ROI, or streak-adaptive averaging with better noise performance.
RESULTS: The bound on the possible dose reduction depends on the degree to which the observer can read through the possibly streaky noise. For the described low contrast detection task with the signal shape and background known exactly, the average dose reduction possible compared to FBP with streak-adaptive averaging was 42% and it was 64% if only the ROI average is used with FBP. The exact amount of dose reduction also depends on the background anatomy, with statistically inhomogeneous backgrounds showing greater benefits.
CONCLUSIONS: The dose reductions from new, statistical reconstruction methods can be bounded. Larger dose reductions in the density estimation task studied here are only possible with the introduction of prior knowledge, which can introduce bias.

Entities:  

Mesh:

Year:  2016        PMID: 26936720      PMCID: PMC4769269          DOI: 10.1118/1.4941954

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Beam shaper with optimized dose utility for helical cone-beam CT.

Authors:  Thomas Köhler; Bernhard Brendel; Roland Proksa
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

4.  Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Synho Do; Jean Baptiste Thibault; Homer Pien; Owen J O'Connor; Owen O J Connor; Michael A Blake
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

5.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  The feasibility of a piecewise-linear dynamic bowtie filter.

Authors:  Scott S Hsieh; Norbert J Pelc
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

7.  Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver.

Authors:  Mark E Baker; Frank Dong; Andrew Primak; Nancy A Obuchowski; David Einstein; Namita Gandhi; Brian R Herts; Andrei Purysko; Erick Remer; Neil Vachhani; Neil Vachani
Journal:  AJR Am J Roentgenol       Date:  2012-07       Impact factor: 3.959

8.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

9.  Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments--a phantom approach.

Authors:  Frédéric A Miéville; François Gudinchet; Francis Brunelle; François O Bochud; Francis R Verdun
Journal:  Phys Med       Date:  2012-01-02       Impact factor: 2.685

10.  Low-dose X-ray CT reconstruction via dictionary learning.

Authors:  Qiong Xu; Hengyong Yu; Xuanqin Mou; Lei Zhang; Jiang Hsieh; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2012-04-20       Impact factor: 10.048

View more
  5 in total

1.  Rapid measurement of the low contrast detectability of CT scanners.

Authors:  Akinyinka Omigbodun; J Y Vaishnav; Scott S Hsieh
Journal:  Med Phys       Date:  2021-01-13       Impact factor: 4.071

2.  Comparison Between Pre-Log and Post-Log Statistical Models in Ultra-Low-Dose CT Reconstruction.

Authors:  Adam M Alessio; Paul E Kinahan; Ken Sauer; Mannudeep K Kalra; Bruno De Man
Journal:  IEEE Trans Med Imaging       Date:  2016-11-09       Impact factor: 10.048

3.  A minimum SNR criterion for computed tomography object detection in the projection domain.

Authors:  Scott S Hsieh; Shuai Leng; Lifeng Yu; Nathan R Huber; Cynthia H McCollough
Journal:  Med Phys       Date:  2022-07-10       Impact factor: 4.506

4.  Statistical characterization of the linear attenuation coefficient in polychromatic CT scans.

Authors:  Gonzalo Vegas; Raúl San José Estépar
Journal:  Med Phys       Date:  2020-10-06       Impact factor: 4.071

5.  Hyper-Heuristic Capacitance Array Method for Multi-Metal Wear Debris Detection.

Authors:  Yanshan Sun; Lecheng Jia; Zhoumo Zeng
Journal:  Sensors (Basel)       Date:  2019-01-26       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.