Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection.

Jing Tang1, Arman Rahmim, Riikka Lautamäki, Martin A Lodge, Frank M Bengel, Benjamin M W Tsui.   

Abstract

The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32x32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm(-1) Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <approximately 3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19420417      PMCID: PMC3071634          DOI: 10.1088/0031-9155/54/10/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  PET myocardial glucose metabolism and perfusion imaging: Part 1-Guidelines for data acquisition and patient preparation.

Authors:  Stephen L Bacharach; Jeroen J Bax; James Case; Dominique Delbeke; Karen A Kurdziel; William H Martin; Randolph E Patterson
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

2.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

Review 3.  Advances in positron emission tomography.

Authors:  Marcelo F Di Carli
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

4.  Statistical dynamic image reconstruction in state-of-the-art high-resolution PET.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Stephan Blinder; Maurie-Laure Camborde; Vesna Sossi
Journal:  Phys Med Biol       Date:  2005-10-04       Impact factor: 3.609

5.  Should PET replace SPECT for evaluating CAD? The end of the beginning.

Authors:  Marcelo F Di Carli; Rory Hachamovitch
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

6.  Comparison of measures of left ventricular function from electrocardiographically gated 82Rb PET with contrast-enhanced CT ventriculography: a hybrid PET/CT analysis.

Authors:  Ankit Chander; Michele Brenner; Riikka Lautamäki; Corina Voicu; Jennifer Merrill; Frank M Bengel
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

Review 7.  ROC methodology in radiologic imaging.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1986-09       Impact factor: 6.016

Review 8.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

9.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

10.  Analytic system matrix resolution modeling in PET: an application to Rb-82 cardiac imaging.

Authors:  A Rahmim; J Tang; M A Lodge; S Lashkari; M R Ay; R Lautamäki; B M W Tsui; F M Bengel
Journal:  Phys Med Biol       Date:  2008-10-03       Impact factor: 3.609

  10 in total
  10 in total

1.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

2.  Exact confidence intervals for channelized Hotelling observer performance in image quality studies.

Authors:  Adam Wunderlich; Frederic Noo; Brandon D Gallas; Marta E Heilbrun
Journal:  IEEE Trans Med Imaging       Date:  2014-09-26       Impact factor: 10.048

3.  Development of a model of the coronary arterial tree for the 4D XCAT phantom.

Authors:  George S K Fung; W Paul Segars; Grant T Gullberg; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2011-08-10       Impact factor: 3.609

4.  Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation.

Authors:  Tyler Kaster; Ilias Mylonas; Jennifer M Renaud; George A Wells; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2012-09-21       Impact factor: 5.952

5.  New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Nucl Sci       Date:  2013-01-11       Impact factor: 1.679

6.  Generation and Evaluation of a Simultaneous Cardiac and Respiratory Gated Rb-82 PET Simulation.

Authors:  Min Jae Park; Si Chen; Taek-Soo Lee; George S K Fung; Martin Lodge; Benjamin M W Tsui
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011-10

7.  Simultaneous measurement of noise and spatial resolution in PET phantom images.

Authors:  Martin A Lodge; Arman Rahmim; Richard L Wahl
Journal:  Phys Med Biol       Date:  2010-01-28       Impact factor: 3.609

8.  Myocardial defect detection using PET-CT: phantom studies.

Authors:  Eugene S Mananga; Georges El Fakhri; Joshua Schaefferkoetter; Ali A Bonab; Jinsong Ouyang
Journal:  PLoS One       Date:  2014-02-05       Impact factor: 3.240

9.  Importance of Defect Detectability in Positron Emission Tomography Imaging of Abdominal Lesions.

Authors:  Shozo Yamashita; Kunihiko Yokoyama; Masahisa Onoguchi; Haruki Yamamoto; Tetsu Nakaichi; Shiro Tsuji; Kenichi Nakajima
Journal:  Asia Ocean J Nucl Med Biol       Date:  2015

10.  Cardiac PET/CT with Rb-82: optimization of image acquisition and reconstruction parameters.

Authors:  P Chilra; S Gnesin; G Allenbach; M Monteiro; J O Prior; L Vieira; J A Pires Jorge
Journal:  EJNMMI Phys       Date:  2017-02-15
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.