Literature DB >> 24434568

Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Jian Zhou1, Jinyi Qi.   

Abstract

A factorized system matrix utilizing an image domain resolution model is attractive in fully 3D time-of-flight PET image reconstruction using list-mode data. In this paper, we study a factored model based on sparse matrix factorization that is comprised primarily of a simplified geometrical projection matrix and an image blurring matrix. Beside the commonly-used Siddon's ray-tracer, we propose another more simplified geometrical projector based on the Bresenham's ray-tracer which further reduces the computational cost. We discuss in general how to obtain an image blurring matrix associated with a geometrical projector, and provide theoretical analysis that can be used to inspect the efficiency in model factorization. In simulation studies, we investigate the performance of the proposed sparse factorization model in terms of spatial resolution, noise properties and computational cost. The quantitative results reveal that the factorization model can be as efficient as a non-factored model, while its computational cost can be much lower. In addition we conduct Monte Carlo simulations to identify the conditions under which the image resolution model can become more efficient in terms of image contrast recovery. We verify our observations using the provided theoretical analysis. The result offers a general guide to achieve the optimal reconstruction performance based on a sparse factorization model with an image domain resolution model.

Entities:  

Mesh:

Year:  2014        PMID: 24434568      PMCID: PMC4182441          DOI: 10.1088/0031-9155/59/3/541

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling.

Authors:  R H Huesman; G J Klein; W W Moses; J Qi; B W Reutter; P R Virador
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA.

Authors:  Jing-Yu Cui; Guillem Pratx; Sven Prevrhal; Craig S Levin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Non-Gaussian space-variant resolution modelling for list-mode reconstruction.

Authors:  C Cloquet; F C Sureau; M Defrise; G Van Simaeys; N Trotta; S Goldman
Journal:  Phys Med Biol       Date:  2010-08-11       Impact factor: 3.609

4.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner.

Authors:  J Qi; R M Leahy; S R Cherry; A Chatziioannou; T H Farquhar
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

5.  Practical considerations for image-based PSF and blobs reconstruction in PET.

Authors:  Simon Stute; Claude Comtat
Journal:  Phys Med Biol       Date:  2013-05-16       Impact factor: 3.609

6.  Online detector response calculations for high-resolution PET image reconstruction.

Authors:  Guillem Pratx; Craig Levin
Journal:  Phys Med Biol       Date:  2011-06-15       Impact factor: 3.609

7.  Modeling and incorporation of system response functions in 3-D whole body PET.

Authors:  Adam M Alessio; Paul E Kinahan; Thomas K Lewellen
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

8.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Authors:  Suleman Surti; Austin Kuhn; Matthew E Werner; Amy E Perkins; Jeffrey Kolthammer; Joel S Karp
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

9.  Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

10.  Impact of image-space resolution modeling for studies with the high-resolution research tomograph.

Authors:  Florent C Sureau; Andrew J Reader; Claude Comtat; Claire Leroy; Maria-Joao Ribeiro; Irène Buvat; Régine Trébossen
Journal:  J Nucl Med       Date:  2008-06       Impact factor: 10.057

View more
  7 in total

1.  Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data.

Authors:  Zheng Zhang; Sean Rose; Jinghan Ye; Amy E Perkins; Buxin Chen; Chien-Min Kao; Emil Y Sidky; Chi-Hua Tung; Xiaochuan Pan
Journal:  IEEE Trans Biomed Eng       Date:  2018-04       Impact factor: 4.538

2.  Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner.

Authors:  Xuezhu Zhang; Jian Zhou; Simon R Cherry; Ramsey D Badawi; Jinyi Qi
Journal:  Phys Med Biol       Date:  2017-02-27       Impact factor: 3.609

3.  Image-based Modeling of PSF Deformation with Application to Limited Angle PET Data.

Authors:  Samuel Matej; Yusheng Li; Joseph Panetta; Joel S Karp; Suleman Surti
Journal:  IEEE Trans Nucl Sci       Date:  2016-09-08       Impact factor: 1.679

Review 4.  3D/4D Reconstruction and Quantitative Total Body Imaging.

Authors:  Jinyi Qi; Samuel Matej; Guobao Wang; Xuezhu Zhang
Journal:  PET Clin       Date:  2021-01

5.  Deep Learning Based Joint PET Image Reconstruction and Motion Estimation.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2022-05-02       Impact factor: 11.037

6.  Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER.

Authors:  Xuezhu Zhang; Zhaoheng Xie; Eric Berg; Martin S Judenhofer; Weiping Liu; Tianyi Xu; Yu Ding; Yang Lv; Yun Dong; Zilin Deng; Songsong Tang; Hongcheng Shi; Pengcheng Hu; Shuguang Chen; Jun Bao; Hongdi Li; Jian Zhou; Guobao Wang; Simon R Cherry; Ramsey D Badawi; Jinyi Qi
Journal:  J Nucl Med       Date:  2019-07-13       Impact factor: 10.057

7.  Generative adversarial network based regularized image reconstruction for PET.

Authors:  Zhaoheng Xie; Reheman Baikejiang; Tiantian Li; Xuezhu Zhang; Kuang Gong; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-06-23       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.