Literature DB >> 20702921

Non-Gaussian space-variant resolution modelling for list-mode reconstruction.

C Cloquet1, F C Sureau, M Defrise, G Van Simaeys, N Trotta, S Goldman.   

Abstract

Partial volume effect is an important source of bias in PET images that can be lowered by accounting for the point spread function (PSF) of the scanner. We measured such a PSF in various points of a clinical PET scanner and modelled it as a product of matrices acting in image space, taking the asymmetrical, shift-varying and non-Gaussian character of the PSF into account (AMP modelling), and we integrated this accurate image space modelling into a conventional list-mode OSEM algorithm (EM-AMP reconstruction). We showed on the one hand that when a sufficiently high number of iterations are considered, the AMP modelling lead to better recovery coefficients at reduced background noise compared to reconstruction where no or only partial resolution modelling is performed, and on the other hand that for a small number of iterations, a Gaussian modelling gave the best recovery coefficients. Moreover, we have demonstrated that a deconvolution based on the AMP system response model leads to the same recovery coefficients as the corresponding EM-AMP reconstruction, but at the expense of an increased background noise.

Entities:  

Mesh:

Year:  2010        PMID: 20702921     DOI: 10.1088/0031-9155/55/17/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

Review 2.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

3.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

Review 4.  Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective.

Authors:  Antonis Kalemis; Bénédicte M A Delattre; Susanne Heinzer
Journal:  MAGMA       Date:  2012-08-07       Impact factor: 2.310

5.  Influence of the partial volume correction method on (18)F-fluorodeoxyglucose brain kinetic modelling from dynamic PET images reconstructed with resolution model based OSEM.

Authors:  Spencer L Bowen; Larry G Byars; Christian J Michel; Daniel B Chonde; Ciprian Catana
Journal:  Phys Med Biol       Date:  2013-09-20       Impact factor: 3.609

6.  PET image super-resolution using generative adversarial networks.

Authors:  Tzu-An Song; Samadrita Roy Chowdhury; Fan Yang; Joyita Dutta
Journal:  Neural Netw       Date:  2020-02-03

7.  Image-based Modeling of PSF Deformation with Application to Limited Angle PET Data.

Authors:  Samuel Matej; Yusheng Li; Joseph Panetta; Joel S Karp; Suleman Surti
Journal:  IEEE Trans Nucl Sci       Date:  2016-09-08       Impact factor: 1.679

8.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

9.  Applications of the line-of-response probability density function resolution model in PET list mode reconstruction.

Authors:  Y Jian; R Yao; T Mulnix; X Jin; R E Carson
Journal:  Phys Med Biol       Date:  2014-12-09       Impact factor: 3.609

10.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Authors:  Y Petibon; J Ouyang; X Zhu; C Huang; T G Reese; S Y Chun; Q Li; G El Fakhri
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.