Online detector response calculations for high-resolution PET image reconstruction.

Guillem Pratx1, Craig Levin.   

Abstract

Positron emission tomography systems are best described by a linear shift-varying model. However, image reconstruction often assumes simplified shift-invariant models to the detriment of image quality and quantitative accuracy. We investigated a shift-varying model of the geometrical system response based on an analytical formulation. The model was incorporated within a list-mode, fully 3D iterative reconstruction process in which the system response coefficients are calculated online on a graphics processing unit (GPU). The implementation requires less than 512 Mb of GPU memory and can process two million events per minute (forward and backprojection). For small detector volume elements, the analytical model compared well to reference calculations. Images reconstructed with the shift-varying model achieved higher quality and quantitative accuracy than those that used a simpler shift-invariant model. For an 8 mm sphere in a warm background, the contrast recovery was 95.8% for the shift-varying model versus 85.9% for the shift-invariant model. In addition, the spatial resolution was more uniform across the field-of-view: for an array of 1.75 mm hot spheres in air, the variation in reconstructed sphere size was 0.5 mm RMS for the shift-invariant model, compared to 0.07 mm RMS for the shift-varying model.

Entities:  

Mesh:

Year:  2011        PMID: 21677367      PMCID: PMC3147176          DOI: 10.1088/0031-9155/56/13/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  An improved analytical detector response function model for multilayer small-diameter PET scanners.

Authors:  D Strul; R B Slates; M Dahlbom; S R Cherry; P K Marsden
Journal:  Phys Med Biol       Date:  2003-04-21       Impact factor: 3.609

2.  Transaxial system models for jPET-D4 image reconstruction.

Authors:  Taiga Yamaya; Naoki Hagiwara; Takashi Obi; Masahiro Yamaguchi; Nagaaki Ohyama; Keishi Kitamura; Tomoyuki Hasegawa; Hideaki Haneishi; Eiji Yoshida; Naoko Inadama; Hideo Murayama
Journal:  Phys Med Biol       Date:  2005-11-01       Impact factor: 3.609

3.  Statistical dynamic image reconstruction in state-of-the-art high-resolution PET.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Stephan Blinder; Maurie-Laure Camborde; Vesna Sossi
Journal:  Phys Med Biol       Date:  2005-10-04       Impact factor: 3.609

4.  Fully 3-D PET reconstruction with system matrix derived from point source measurements.

Authors:  Vladimir Y Panin; Frank Kehren; Christian Michel; Michael Casey
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

5.  FIRST: Fast Iterative Reconstruction Software for (PET) tomography.

Authors:  J L Herraiz; S España; J J Vaquero; M Desco; J M Udías
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

6.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

7.  Modeling and incorporation of system response functions in 3-D whole body PET.

Authors:  Adam M Alessio; Paul E Kinahan; Thomas K Lewellen
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

8.  Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

Authors:  Y Gu; J L Matteson; R T Skelton; A C Deal; E A Stephan; F Duttweiler; T M Gasaway; C S Levin
Journal:  Phys Med Biol       Date:  2011-02-18       Impact factor: 3.609

9.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.

Authors:  Yuchuan Wang; Jurgen Seidel; Benjamin M W Tsui; Juan J Vaquero; Martin G Pomper
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

10.  Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.

Authors:  F Habte; A M K Foudray; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2007-05-29       Impact factor: 3.609

View more
  6 in total

1.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

2.  Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.

Authors:  Don Vernekohl; Moiz Ahmad; Garry Chinn; Lei Xing
Journal:  Phys Med Biol       Date:  2016-11-15       Impact factor: 3.609

3.  Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems.

Authors:  Daniel B Keesing; Aswin Mathews; Sergey Komarov; Heyu Wu; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

4.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

5.  High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid.

Authors:  J Cabello; J E Gillam; M Rafecas
Journal:  Int J Biomed Imaging       Date:  2012-04-02

6.  Accelerating image reconstruction in dual-head PET system by GPU and symmetry properties.

Authors:  Cheng-Ying Chou; Yun Dong; Yukai Hung; Yu-Jiun Kao; Weichung Wang; Chien-Min Kao; Chin-Tu Chen
Journal:  PLoS One       Date:  2012-12-26       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.