Impact of image-space resolution modeling for studies with the high-resolution research tomograph.

Florent C Sureau1, Andrew J Reader, Claude Comtat, Claire Leroy, Maria-Joao Ribeiro, Irène Buvat, Régine Trébossen.   

Abstract

UNLABELLED: Brain PET in small structures is challenged by low resolution inducing bias in the activity measurements. Improved spatial resolution may be obtained by using dedicated tomographs and more comprehensive modeling of the acquisition system during reconstruction. In this study, we assess the impact of resolution modeling (RM) during reconstruction on image quality and on the estimates of biologic parameters in a clinical study performed on a high-resolution research tomograph.
METHODS: An accelerated list-mode ordinary Poisson ordered-subset expectation maximization (OP-OSEM) algorithm, including sinogram-based corrections and an experimental stationary model of resolution, has been designed. Experimental phantom studies are used to assess contrast and noise characteristics of the reconstructed images. The binding potential of a selective tracer of the dopamine transporter is also assessed in anatomic volumes of interest in a 5-patient study.
RESULTS: In the phantom experiment, a slower convergence and a higher contrast recovery are observed for RM-OP-OSEM than for OP-OSEM for the same level of statistical noise. RM-OP-OSEM yields contrast recovery levels that could not be reached without RM as well as better visual recovery of the smallest spheres and better delineation of the structures in the reconstructed images. Statistical noise has lower variance at the voxel level with RM than without at matched resolution. In a uniform activity region, RM induces higher positive and lower negative correlations with neighboring voxels, leading to lower spatial variance. Clinical images reconstructed with RM demonstrate better delineation of cortical and subcortical structures in both time-averaged and parametric images. The binding potential in the striatum is also increased, a result similar to the one observed in the phantom study.
CONCLUSION: In high-resolution PET, RM during reconstruction improves quantitative accuracy by reducing the partial-volume effects.

Entities:  

Mesh:

Year:  2008        PMID: 18511844     DOI: 10.2967/jnumed.107.045351

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  60 in total

Review 1.  The development, past achievements, and future directions of brain PET.

Authors:  Terry Jones; Eugenii A Rabiner
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-21       Impact factor: 6.200

2.  Effects of point spread function-based image reconstruction on neuroreceptor binding in positron emission tomography study with [(11)C]FLB 457.

Authors:  Thonnapong Thongpraparn; Yoko Ikoma; Takahiro Shiraishi; Taiga Yamaya; Hiroshi Ito
Journal:  Radiol Phys Technol       Date:  2015-12-16

3.  Association Between Sumatriptan Treatment During a Migraine Attack and Central 5-HT1B Receptor Binding.

Authors:  Marie Deen; Anders Hougaard; Hanne Demant Hansen; Martin Schain; Agnete Dyssegaard; Gitte Moos Knudsen; Messoud Ashina
Journal:  JAMA Neurol       Date:  2019-07-01       Impact factor: 18.302

4.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

5.  Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT.

Authors:  Andrea Varrone; Nils Sjöholm; Lars Eriksson; Balazs Gulyás; Christer Halldin; Lars Farde
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-05-13       Impact factor: 9.236

6.  Small-animal imaging using clinical positron emission tomography/computed tomography and super-resolution.

Authors:  Frank P DiFilippo; Sagar Patel; Kewal Asosingh; Serpil C Erzurum
Journal:  Mol Imaging       Date:  2012-06       Impact factor: 4.488

Review 7.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

8.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

9.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

10.  Applications of the line-of-response probability density function resolution model in PET list mode reconstruction.

Authors:  Y Jian; R Yao; T Mulnix; X Jin; R E Carson
Journal:  Phys Med Biol       Date:  2014-12-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.