Literature DB >> 11021696

List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling.

R H Huesman1, G J Klein, W W Moses, J Qi, B W Reutter, P R Virador.   

Abstract

We present a preliminary study of list-mode likelihood reconstruction of images for a rectangular positron emission tomograph (PET) specifically designed to image the human breast. The prospective device consists of small arrays of scintillation crystals for which depth of interaction is estimated. Except in very rare instances, the number of annihilation events detected is expected to be far less than the number of distinguishable events. If one were to histogram the acquired data, most histogram bins would remain vacant. Therefore, it seems natural to investigate the efficacy of processing events one at a time rather than processing the data in histogram format. From a reconstruction perspective, the new tomograph presents a challenge in that the rectangular geometry leads to irregular radial and angular sampling, and the field of view extends completely to the detector faces. Simulations are presented that indicate that the proposed tomograph can detect 8-mm-diameter spherical tumors with a tumor-to-background tracer density ratio of 3:1 using realistic image acquisition parameters. Spherical tumors of 4-mm diameter are near the limit of detectability with the image acquisition parameters used. Expressions are presented to estimate the loss of image contrast due to Compton scattering.

Entities:  

Mesh:

Year:  2000        PMID: 11021696     DOI: 10.1109/42.870263

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  33 in total

1.  A generalized reconstruction framework for unconventional PET systems.

Authors:  Aswin John Mathews; Ke Li; Sergey Komarov; Qiang Wang; Bosky Ravindranath; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Improving PET imaging for breast cancer using virtual pinhole PET half-ring insert.

Authors:  Aswin John Mathews; Sergey Komarov; Heyu Wu; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2013-09-02       Impact factor: 3.609

3.  Effect of errors in the system matrix on maximum a posteriori image reconstruction.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2005-07-06       Impact factor: 3.609

4.  Regularization parameter selection for penalized-likelihood list-mode image reconstruction in PET.

Authors:  Mengxi Zhang; Jian Zhou; Xiaofeng Niu; Evren Asma; Wenli Wang; Jinyi Qi
Journal:  Phys Med Biol       Date:  2017-04-12       Impact factor: 3.609

5.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

Review 6.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

7.  Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET.

Authors:  Kuang Gong; Jian Zhou; Michel Tohme; Martin Judenhofer; Yongfeng Yang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2017-06-02       Impact factor: 10.048

8.  Detection performance analysis for time-of-flight PET.

Authors:  Nannan Cao; Ronald H Huesman; William W Moses; Jinyi Qi
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

9.  Quantitative Accuracy of Penalized-Likelihood Reconstruction for ROI Activity Estimation.

Authors:  Lin Fu; Jennifer R Stickel; Ramsey D Badawi; Jinyi Qi
Journal:  IEEE Trans Nucl Sci       Date:  2009-02-01       Impact factor: 1.679

10.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.