Literature DB >> 24412172

Model-based correction of tissue compression for tracked ultrasound in soft tissue image-guided surgery.

Thomas S Pheiffer1, Reid C Thompson2, Daniel C Rucker3, Amber L Simpson3, Michael I Miga4.   

Abstract

Acquisition of ultrasound data negatively affects image registration accuracy during image-guided therapy because of tissue compression by the probe. We present a novel compression correction method that models sub-surface tissue displacement resulting from application of a tracked probe to the tissue surface. Patient landmarks are first used to register the probe pose to pre-operative imaging. The ultrasound probe geometry is used to provide boundary conditions to a biomechanical model of the tissue. The deformation field solution of the model is inverted to non-rigidly transform the ultrasound images to an estimation of the tissue geometry before compression. Experimental results with gel phantoms indicated that the proposed method reduced the tumor margin modified Hausdorff distance (MHD) from 5.0 ± 1.6 to 1.9 ± 0.6 mm, and reduced tumor centroid alignment error from 7.6 ± 2.6 to 2.0 ± 0.9 mm. The method was applied to a clinical case and reduced the tumor margin MHD error from 5.4 ± 0.1 to 2.6 ± 0.1 mm and the centroid alignment error from 7.2 ± 0.2 to 3.5 ± 0.4 mm.
Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biomechanical model; Boundary conditions; Finite-element model; Image registration; Image-guided surgery; Tissue deformation

Mesh:

Year:  2014        PMID: 24412172      PMCID: PMC3943567          DOI: 10.1016/j.ultrasmedbio.2013.11.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  23 in total

1.  Beam calibration without a phantom for creating a 3-D freehand ultrasound system.

Authors:  D M Muratore; R L Galloway
Journal:  Ultrasound Med Biol       Date:  2001-11       Impact factor: 2.998

2.  Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement.

Authors:  Xavier Artignan; Monique H P Smitsmans; Jos V Lebesque; David A Jaffray; Marcel van Her; Harry Bartelink
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-06-01       Impact factor: 7.038

3.  Design and evaluation of an optically-tracked single-CCD laser range scanner.

Authors:  Thomas S Pheiffer; Amber L Simpson; Brian Lennon; Reid C Thompson; Michael I Miga
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

Review 4.  A review of calibration techniques for freehand 3-D ultrasound systems.

Authors:  Laurence Mercier; Thomas Langø; Frank Lindseth; D Louis Collins
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

5.  RF and amplitude-based probe pressure correction for 3D ultrasound.

Authors:  Graham M Treece; Andrew H Gee; Richard W Prager
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

6.  Bootstrapped ultrasound calibration.

Authors:  Emad M Boctor; Iulian Iordachita; Michael A Choti; Gregory Hager; Gabor Fichtinger
Journal:  Stud Health Technol Inform       Date:  2006

7.  Laser range scanning for image-guided neurosurgery: investigation of image-to-physical space registrations.

Authors:  Aize Cao; R C Thompson; P Dumpuri; B M Dawant; R L Galloway; S Ding; M I Miga
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

8.  Comparison of freehand 3-D ultrasound calibration techniques using a stylus.

Authors:  Po-Wei Hsu; Graham M Treece; Richard W Prager; Neil E Houghton; Andrew H Gee
Journal:  Ultrasound Med Biol       Date:  2008-04-16       Impact factor: 2.998

9.  Toward a preoperative planning tool for brain tumor resection therapies.

Authors:  Aaron M Coffey; Michael I Miga; Ishita Chen; Reid C Thompson
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-25       Impact factor: 2.924

10.  Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging.

Authors:  K J M Surry; H J B Austin; A Fenster; T M Peters
Journal:  Phys Med Biol       Date:  2004-12-21       Impact factor: 3.609

View more
  8 in total

1.  Toward a generic real-time compression correction framework for tracked ultrasound.

Authors:  Thomas S Pheiffer; Michael I Miga
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

Review 2.  How Sensor, Signal, and Imaging Informatics May Impact Patient Centered Care and Care Coordination.

Authors:  S Voros; A Moreau-Gaudry
Journal:  Yearb Med Inform       Date:  2015-08-13

3.  Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound.

Authors:  Logan W Clements; Jarrod A Collins; Jared A Weis; Amber L Simpson; Lauryn B Adams; William R Jarnagin; Michael I Miga
Journal:  J Med Imaging (Bellingham)       Date:  2016-03-23

4.  Signal dropout correction-based ultrasound segmentation for diastolic mitral valve modeling.

Authors:  Wenyao Xia; John Moore; Elvis C S Chen; Yuanwei Xu; Olivia Ginty; Daniel Bainbridge; Terry M Peters
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-09

5.  Realization of a biomechanical model-assisted image guidance system for breast cancer surgery using supine MRI.

Authors:  Rebekah H Conley; Ingrid M Meszoely; Jared A Weis; Thomas S Pheiffer; Lori R Arlinghaus; Thomas E Yankeelov; Michael I Miga
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-06-20       Impact factor: 2.924

6.  Value of ultrasound elastography combined with contrast-enhanced ultrasound and micro-flow imaging in differential diagnosis of benign and malignant breast lesions.

Authors:  Zuopeng Ding; Weiyong Liu; Nianan He; Xiaopeng Ma; Lili Fu; Lei Ye
Journal:  Am J Transl Res       Date:  2021-12-15       Impact factor: 4.060

7.  Current Evidence in Image-Guided Liver Surgery.

Authors:  Amber L Simpson; T Peter Kingham
Journal:  J Gastrointest Surg       Date:  2016-03-08       Impact factor: 3.452

8.  Non-rigid registration of 3D ultrasound for neurosurgery using automatic feature detection and matching.

Authors:  Inês Machado; Matthew Toews; Jie Luo; Prashin Unadkat; Walid Essayed; Elizabeth George; Pedro Teodoro; Herculano Carvalho; Jorge Martins; Polina Golland; Steve Pieper; Sarah Frisken; Alexandra Golby; William Wells
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-04       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.