Literature DB >> 15831328

RF and amplitude-based probe pressure correction for 3D ultrasound.

Graham M Treece1, Andrew H Gee, Richard W Prager.   

Abstract

Anatomical deformation caused by variable probe contact pressure is a significant problem in freehand 3D ultrasound, particularly for high resolution musculoskeletal and breast scans. We have previously published an amplitude-based algorithm for correcting such errors. In this paper, we compare this approach with a novel, elastography-inspired algorithm which works with the higher resolution radio-frequency (RF) signal. The results show that, although the RF-based algorithm is more precise in certain circumstances, both algorithms are able to compensate for probe pressure in 3D ultrasound data. Consequently, freehand 3D ultrasound users who do not have access to the RF signal are still in a position to perform effective probe pressure correction using the readily available video output, as long as this signal is not affected by significant amounts of frame averaging (persistence).

Mesh:

Year:  2005        PMID: 15831328     DOI: 10.1016/j.ultrasmedbio.2004.12.018

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Toward a generic real-time compression correction framework for tracked ultrasound.

Authors:  Thomas S Pheiffer; Michael I Miga
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

2.  Prefraction displacement and intrafraction drift of the prostate due to perineal ultrasound probe pressure.

Authors:  Minglun Li; Nina-Sophie Hegemann; Farkhad Manapov; Anne Kolberg; Patrick Dominik Thum; Ute Ganswindt; Claus Belka; Hendrik Ballhausen
Journal:  Strahlenther Onkol       Date:  2017-02-14       Impact factor: 3.621

3.  Model-based correction of tissue compression for tracked ultrasound in soft tissue image-guided surgery.

Authors:  Thomas S Pheiffer; Reid C Thompson; Daniel C Rucker; Amber L Simpson; Michael I Miga
Journal:  Ultrasound Med Biol       Date:  2014-01-10       Impact factor: 2.998

4.  Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation.

Authors:  Anthony Landry; Tanya Berrang; Isabelle Gagne; Carmen Popescu; Tracy Mitchell; Hazel Vey; Letricia Sand; Siew Yan Soh; Jill Wark; Ivo Olivotto; Wayne Beckham
Journal:  Radiat Oncol       Date:  2014-01-27       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.