Literature DB >> 15724540

Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging.

K J M Surry1, H J B Austin, A Fenster, T M Peters.   

Abstract

Poly(vinyl alcohol) cryogel, PVA-C, is presented as a tissue-mimicking material, suitable for application in magnetic resonance (MR) imaging and ultrasound imaging. A 10% by weight poly(vinyl alcohol) in water solution was used to form PVA-C, which is solidified through a freeze-thaw process. The number of freeze-thaw cycles affects the properties of the material. The ultrasound and MR imaging characteristics were investigated using cylindrical samples of PVA-C. The speed of sound was found to range from 1520 to 1540 m s(-1), and the attenuation coefficients were in the range of 0.075-0.28 dB (cm MHz)(-1). T1 and T2 relaxation values were found to be 718-1034 ms and 108-175 ms, respectively. We also present applications of this material in an anthropomorphic brain phantom, a multi-volume stenosed vessel phantom and breast biopsy phantoms. Some suggestions are made for how best to handle this material in the phantom design and development process.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15724540     DOI: 10.1088/0031-9155/49/24/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  50 in total

1.  A nonlinear elasticity phantom containing spherical inclusions.

Authors:  Theo Z Pavan; Ernest L Madsen; Gary R Frank; Jingfeng Jiang; Antonio A O Carneiro; Timothy J Hall
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

2.  Remote temperature estimation in intravascular photoacoustic imaging.

Authors:  Shriram Sethuraman; Salavat R Aglyamov; Richard W Smalling; Stanislav Y Emelianov
Journal:  Ultrasound Med Biol       Date:  2007-10-23       Impact factor: 2.998

3.  Quantitative sparse array vascular elastography: the impact of tissue attenuation and modulus contrast on performance.

Authors:  Steven Huntzicker; Rohit Nayak; Marvin M Doyley
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-04

4.  Energy-based adaptive focusing of waves: application to noninvasive aberration correction of ultrasonic wavefields.

Authors:  Eric Herbert; Mathieu Pernot; Gabriel Montaldo; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

5.  Bilayer aberration-inducing gel phantom for high intensity focused ultrasound applications.

Authors:  Alex T Peek; Christopher Hunter; Wayne Kreider; Tatiana D Khokhlova; Pavel B Rosnitskiy; Petr V Yuldashev; Oleg A Sapozhnikov; Vera A Khokhlova
Journal:  J Acoust Soc Am       Date:  2020-12       Impact factor: 1.840

6.  Effects of line fiducial parameters and beamforming on ultrasound calibration.

Authors:  Golafsoun Ameri; John S H Baxter; A Jonathan McLeod; Terry M Peters; Elvis C S Chen
Journal:  J Med Imaging (Bellingham)       Date:  2017-02-28

7.  Analysis of multiple shear wave modes in a nonlinear soft solid: Experiments and finite element simulations with a tilted acoustic radiation force.

Authors:  Annette Caenen; Anna E Knight; Ned C Rouze; Nick B Bottenus; Patrick Segers; Kathryn R Nightingale
Journal:  J Mech Behav Biomed Mater       Date:  2020-04-08

8.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

9.  Nanoparticle transport phenomena in confined flows.

Authors:  Ravi Radhakrishnan; Samaneh Farokhirad; David M Eckmann; Portonovo S Ayyaswamy
Journal:  Adv Heat Transf       Date:  2019-10-04

10.  Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Authors:  Kenichi Funamoto; Osamu Yamashita; Toshiyuki Hayase
Journal:  J Med Ultrason (2001)       Date:  2014-08-05       Impact factor: 1.314

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.