Literature DB >> 24390008

Patient-specific instruments in total knee arthroplasty.

Fabio Conteduca1, Raffaele Iorio, Daniele Mazza, Andrea Ferretti.   

Abstract

PURPOSE: In recent years, patient-specific instruments (PSI) has been introduced with the aim of reducing the overall costs of the implants, minimising the size and number of instruments required, and also reducing surgery time. The purpose of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability of patient specific instrument system in total knee arthroplasty (TKA).
METHODS: A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications.
RESULTS: Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%.
CONCLUSIONS: PSI seem not to be able to result in the same degree of accuracy as the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.

Entities:  

Mesh:

Year:  2014        PMID: 24390008      PMCID: PMC3923927          DOI: 10.1007/s00264-013-2230-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  30 in total

1.  The importance of tibial alignment: finite element analysis of tibial malalignment.

Authors:  A Perillo-Marcone; D S Barrett; M Taylor
Journal:  J Arthroplasty       Date:  2000-12       Impact factor: 4.757

2.  Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique.

Authors:  Pak Lin Chin; Kuang Ying Yang; Seng Jin Yeo; Ngai Nung Lo
Journal:  J Arthroplasty       Date:  2005-08       Impact factor: 4.757

3.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment.

Authors:  Brian A Klatt; Nitin Goyal; Matthew S Austin; William J Hozack
Journal:  J Arthroplasty       Date:  2008-01       Impact factor: 4.757

4.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

Review 5.  Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery.

Authors:  J Bohannon Mason; Thomas K Fehring; Rhonda Estok; Deirdre Banel; Kyle Fahrbach
Journal:  J Arthroplasty       Date:  2007-12       Impact factor: 4.757

6.  Are patient-specific cutting blocks cost-effective for total knee arthroplasty?

Authors:  Ryan M Nunley; Bradley S Ellison; Erin L Ruh; Brandon M Williams; Keith Foreman; Adrienne D Ford; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-12-20       Impact factor: 4.176

7.  Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA.

Authors:  Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

8.  A comparison of conventional and patient-specific instruments in total knee arthroplasty.

Authors:  Kiriakos Daniilidis; Carsten O Tibesku
Journal:  Int Orthop       Date:  2013-07-31       Impact factor: 3.075

9.  The value of patient-matched instrumentation in total knee arthroplasty.

Authors:  John W Noble; Chris A Moore; Ning Liu
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

10.  Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique.

Authors:  F Conteduca; F Massai; R Iorio; E Zanzotto; D Luzon; A Ferretti
Journal:  Int Orthop       Date:  2008-09-02       Impact factor: 3.075

View more
  14 in total

Review 1.  Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants.

Authors:  Eric Alexander Lewallen; Scott M Riester; Carolina A Bonin; Hilal Maradit Kremers; Amel Dudakovic; Sanjeev Kakar; Robert C Cohen; Jennifer J Westendorf; David G Lewallen; Andre J van Wijnen
Journal:  Tissue Eng Part B Rev       Date:  2014-12-18       Impact factor: 6.389

2.  Comment on Conteduca et al.: patient-specific instruments in total knee arthroplasty.

Authors:  Raju Vaishya; Vipul Vijay
Journal:  Int Orthop       Date:  2014-04-03       Impact factor: 3.075

Review 3.  Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis.

Authors:  Etienne Cavaignac; Regis Pailhé; Gregoire Laumond; Jérôme Murgier; Nicolas Reina; Jean Michel Laffosse; Emilie Bérard; Philippe Chiron
Journal:  Int Orthop       Date:  2014-10-10       Impact factor: 3.075

4.  Reply to letter to editor: patient-specific instruments in total knee arthroplasty.

Authors:  Daniele Mazza; Fabio Conteduca; Raffaele Iorio; Andrea Ferretti
Journal:  Int Orthop       Date:  2014-04-11       Impact factor: 3.075

Review 5.  Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis.

Authors:  Jelle P van der List; Harshvardhan Chawla; Leo Joskowicz; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-06       Impact factor: 4.342

Review 6.  [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

Authors:  J Beckmann; A Steinert; C Zilkens; A Zeh; C Schnurr; M Schmitt-Sody; M Gebauer
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

7.  Patient specific instrumentation versus conventional knee arthroplasty: comparative study.

Authors:  Vlad Predescu; Catalin Prescura; Razvan Olaru; Liliana Savin; Paul Botez; Bogdan Deleanu
Journal:  Int Orthop       Date:  2016-12-19       Impact factor: 3.075

8.  Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study.

Authors:  Andrzej Kotela; Ireneusz Kotela
Journal:  Int Orthop       Date:  2014-06-28       Impact factor: 3.075

Review 9.  [Total knee arthroplasty. Patient-specific instruments and implants].

Authors:  Andre F Steinert; Boris M Holzapfel; Lukas Sefrin; Jörg Arnholdt; Maik Hoberg; Maximilian Rudert
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

10.  Clinical and radiographic outcomes of an accelerometer-based system for the tibial resection in total knee arthroplasty.

Authors:  Raffaele Iorio; Daniele Mazza; Piergiorgio Drogo; Gabriele Bolle; Fabio Conteduca; Andrea Redler; Luigi Valeo; Jacopo Conteduca; Andrea Ferretti
Journal:  Int Orthop       Date:  2014-10-10       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.