Literature DB >> 1894655

Coronal alignment after total knee replacement.

R S Jeffery1, R W Morris, R A Denham.   

Abstract

Maquet's line passes from the centre of the femoral head to the centre of the body of the talus. The distance of this line from the centre of the knee on a long-leg radiograph provides the most accurate measure of coronal alignment. Malalignment causes abnormal forces which may lead to loosening after knee replacement. We report a series of 115 Denham knee replacements performed between 1976 and 1981 using the earliest design of components, inserted with intramedullary guide rods. Patients were assessed clinically and long-leg standing radiographs were taken before operation, soon after surgery and up to 12 years later. In two-thirds of the knees (68%) Maquet's line passed through the middle third of the prosthesis on postoperative films and the incidence of subsequent loosening was 3%. When Maquet's line was medial or lateral to this, an error of approximately +/- 3 degrees, the incidence of loosening at a median period of eight years was 24%. This difference is highly significant (p = 0.001). Accurate coronal alignment appears to be an important factor in prevention of loosening. Means of improving the accuracy of alignment and of measuring it on long-leg radiographs are discussed.

Entities:  

Mesh:

Year:  1991        PMID: 1894655

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  249 in total

1.  [CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study].

Authors:  H Bäthis; L Perlick; C Lüring; T Kalteis; J Grifka
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; C Perlick; J Grifka
Journal:  Int Orthop       Date:  2004-01-17       Impact factor: 3.075

3.  Prosthetic alignment and sizing in computer-assisted total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Nobuhiro Tsumura; Masahiro Kurosaka; Hirotsugu Muratsu; Ryosuke Kuroda; Katsuhiko Ishimoto; Kazuo Tsujimoto; Ryoichi Shiba; Shinichi Yoshiya
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

4.  [Total knee arthroplasty--navigation as the standard].

Authors:  L Kinzl; F Gebhard; P Keppler
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

5.  Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique.

Authors:  Lars Perlick; Holger Bäthis; Carsten Perlick; Christian Lüring; Markus Tingart; Joachim Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-08       Impact factor: 4.342

6.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

7.  Relationship between the tibial anteroposterior axis and the surgical epicondylar axis in varus and valgus knees.

Authors:  Shinya Kawahara; Shuichi Matsuda; Ken Okazaki; Yasutaka Tashiro; Hiroaki Mitsuyasu; Hiroyuki Nakahara; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-29       Impact factor: 4.342

8.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

Review 9.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

10.  Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA.

Authors:  Eun-Kyoo Song; Jong-Keun Seon; Ji-Hyeon Yim; Nathan A Netravali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.