Literature DB >> 24338944

Noncontrast enhanced four-dimensional dynamic MRA with golden angle radial acquisition and K-space weighted image contrast (KWIC) reconstruction.

Hee Kwon Song1, Lirong Yan, Robert X Smith, Yiqun Xue, Stanislas Rapacchi, Subashini Srinivasan, Daniel B Ennis, Peng Hu, Nader Pouratian, Danny J J Wang.   

Abstract

PURPOSE: To explore the feasibility of 2D and 3D golden-angle radial acquisition strategies in conjunction with k-space weighted image contrast (KWIC) temporal filtering to achieve noncontrast enhanced dynamic MRA (dMRA) with high spatial resolution, low streaking artifacts and high temporal fidelity.
METHODS: Simulations and in vivo examinations in eight normal volunteers and an arteriovenous malformation patient were carried out. Both 2D and 3D golden angle radial sequences, preceded by spin tagging, were used for dMRA of the brain. The radial dMRA data were temporally filtered using the KWIC strategy and compared with matched standard Cartesian techniques.
RESULTS: The 2D and 3D dynamic MRA image series acquired with the proposed radial techniques demonstrated excellent image quality without discernible temporal blurring compared with standard Cartesian based approaches. The image quality of radial dMRA was equivalent to or higher than that of Cartesian dMRA by visual inspection. A reduction factor of up to 10 and 3 in scan time was achieved for 2D and 3D radial dMRA compared with the Cartesian-based counterparts.
CONCLUSION: The proposed 2D and 3D radial dMRA techniques demonstrated image quality comparable or even superior to those obtained with standard Cartesian methods, but within a fraction of the scan time.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  KWIC; dynamic MRA; golden angle; radial MRI

Mesh:

Substances:

Year:  2013        PMID: 24338944      PMCID: PMC4055554          DOI: 10.1002/mrm.25057

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  GRAPPA operator for wider radial bands (GROWL) with optimally regularized self-calibration.

Authors:  Wei Lin; Feng Huang; Yu Li; Arne Reykowski
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Highly constrained backprojection for time-resolved MRI.

Authors:  C A Mistretta; O Wieben; J Velikina; W Block; J Perry; Y Wu; K Johnson; Y Wu
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

3.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

4.  Nonenhanced ECG-gated time-resolved 4D steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA).

Authors:  Rotem Shlomo Lanzman; Patric Kröpil; Peter Schmitt; Xiaoming Bi; Michael Gliem; Falk R Miese; Daniel Hänggi; Marcel Kamp; Axel Scherer; Bernd Turowski; Dirk Blondin
Journal:  Eur Radiol       Date:  2011-01-12       Impact factor: 5.315

5.  Gadgetron: an open source framework for medical image reconstruction.

Authors:  Michael Schacht Hansen; Thomas Sangild Sørensen
Journal:  Magn Reson Med       Date:  2012-07-12       Impact factor: 4.668

6.  Fast l₁-SPIRiT compressed sensing parallel imaging MRI: scalable parallel implementation and clinically feasible runtime.

Authors:  Mark Murphy; Marcus Alley; James Demmel; Kurt Keutzer; Shreyas Vasanawala; Michael Lustig
Journal:  IEEE Trans Med Imaging       Date:  2012-02-15       Impact factor: 10.048

7.  In vivo venous blood T1 measurement using inversion recovery true-FISP in children and adults.

Authors:  Wen-Chau Wu; Varsha Jain; Cheng Li; Mariel Giannetta; Hallam Hurt; Felix W Wehrli; Danny J J Wang
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

8.  Use of a computer-controlled motion phantom to investigate the temporal and spatial fidelity of HYPR processing.

Authors:  Lauren Keith; Mahdi Rahimi; James Holmes; Jean Brittain; Frank Korosec
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Akira Fujikawa; Junichi Hachiya
Journal:  Eur Radiol       Date:  2004-03-20       Impact factor: 5.315

10.  High-Performance 3D Compressive Sensing MRI Reconstruction Using Many-Core Architectures.

Authors:  Daehyun Kim; Joshua Trzasko; Mikhail Smelyanskiy; Clifton Haider; Pradeep Dubey; Armando Manduca
Journal:  Int J Biomed Imaging       Date:  2011-09-14
View more
  18 in total

1.  Low-dose CT perfusion with projection view sharing.

Authors:  Thomas Martin; John Hoffman; Jeff R Alger; Michael McNitt-Gray; Danny Jj Wang
Journal:  Med Phys       Date:  2017-11-17       Impact factor: 4.071

Review 2.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

3.  Quantification of intracranial arterial blood flow using noncontrast enhanced 4D dynamic MR angiography.

Authors:  Xingfeng Shao; Ziwei Zhao; Jonathan Russin; Arun Amar; Nerses Sanossian; Danny Jj Wang; Lirong Yan
Journal:  Magn Reson Med       Date:  2019-03-07       Impact factor: 4.668

4.  Accelerated noncontrast-enhanced 4-dimensional intracranial MR angiography using golden-angle stack-of-stars trajectory and compressed sensing with magnitude subtraction.

Authors:  Ziwu Zhou; Fei Han; Songlin Yu; Dandan Yu; Stanislas Rapacchi; Hee Kwon Song; Danny J J Wang; Peng Hu; Lirong Yan
Journal:  Magn Reson Med       Date:  2017-05-07       Impact factor: 4.668

5.  Rapid dynamic contrast-enhanced MRI for small animals at 7T using 3D ultra-short echo time and golden-angle radial sparse parallel MRI.

Authors:  Jin Zhang; Li Feng; Ricardo Otazo; Sungheon Gene Kim
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

6.  Golden-ratio rotated stack-of-stars acquisition for improved volumetric MRI.

Authors:  Ziwu Zhou; Fei Han; Lirong Yan; Danny J J Wang; Peng Hu
Journal:  Magn Reson Med       Date:  2017-02-06       Impact factor: 4.668

7.  Vascular territorial segmentation and volumetric blood flow measurement using dynamic contrast enhanced magnetic resonance angiography of the brain.

Authors:  Oren Geri; Shelly I Shiran; Jonathan Roth; Moran Artzi; Liat Ben-Sira; Dafna Ben Bashat
Journal:  J Cereb Blood Flow Metab       Date:  2017-04-10       Impact factor: 6.200

8.  High-resolution dynamic oxygen-17 MR imaging of mouse brain with golden-ratio-based radial sampling and k-space-weighted image reconstruction.

Authors:  Yuchi Liu; Yifan Zhang; Chunying Wu; Junqing Zhu; Charlie Wang; Nicholas Tomko; Mikhail D Linetsky; Robert G Salomon; Ciro Ramos-Estebanez; Yanming Wang; Xin Yu
Journal:  Magn Reson Med       Date:  2017-03-13       Impact factor: 4.668

9.  Time-encoded golden angle radial arterial spin labeling: Simultaneous acquisition of angiography and perfusion data.

Authors:  Merlijn C E van der Plas; Sophie Schmid; Maarten J Versluis; Thomas W Okell; Matthias J P van Osch
Journal:  NMR Biomed       Date:  2021-05-03       Impact factor: 4.478

10.  A novel sequence for simultaneous measurement of whole-brain static and dynamic MRA, intracranial vessel wall image, and T1 -weighted structural brain MRI.

Authors:  Zhensen Chen; Zechen Zhou; Haikun Qi; Huijun Chen; Baocheng Chu; Thomas S Hatsukami; Chun Yuan; Niranjan Balu
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.