Literature DB >> 22345529

Fast l₁-SPIRiT compressed sensing parallel imaging MRI: scalable parallel implementation and clinically feasible runtime.

Mark Murphy1, Marcus Alley, James Demmel, Kurt Keutzer, Shreyas Vasanawala, Michael Lustig.   

Abstract

We present l₁-SPIRiT, a simple algorithm for auto calibrating parallel imaging (acPI) and compressed sensing (CS) that permits an efficient implementation with clinically-feasible runtimes. We propose a CS objective function that minimizes cross-channel joint sparsity in the wavelet domain. Our reconstruction minimizes this objective via iterative soft-thresholding, and integrates naturally with iterative self-consistent parallel imaging (SPIRiT). Like many iterative magnetic resonance imaging reconstructions, l₁-SPIRiT's image quality comes at a high computational cost. Excessively long runtimes are a barrier to the clinical use of any reconstruction approach, and thus we discuss our approach to efficiently parallelizing l₁-SPIRiT and to achieving clinically-feasible runtimes. We present parallelizations of l₁-SPIRiT for both multi-GPU systems and multi-core CPUs, and discuss the software optimization and parallelization decisions made in our implementation. The performance of these alternatives depends on the processor architecture, the size of the image matrix, and the number of parallel imaging channels. Fundamentally, achieving fast runtime requires the correct trade-off between cache usage and parallelization overheads. We demonstrate image quality via a case from our clinical experimentation, using a custom 3DFT spoiled gradient echo (SPGR) sequence with up to 8× acceleration via Poisson-disc undersampling in the two phase-encoded directions.

Entities:  

Mesh:

Year:  2012        PMID: 22345529      PMCID: PMC3522122          DOI: 10.1109/TMI.2012.2188039

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  25 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH.

Authors:  Martin Uecker; Shuo Zhang; Jens Frahm
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

3.  A rapid and robust numerical algorithm for sensitivity encoding with sparsity constraints: self-feeding sparse SENSE.

Authors:  Feng Huang; Yunmei Chen; Wotao Yin; Wei Lin; Xiaojing Ye; Weihong Guo; Arne Reykowski
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

4.  High-performance 3D compressive sensing MRI reconstruction.

Authors:  Daehyun Kim; Joshua D Trzasko; Mikhail Smelyanskiy; Clifton R Haider; Armando Manduca; Pradeep Dubey
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

5.  Array compression for MRI with large coil arrays.

Authors:  Martin Buehrer; Klaas P Pruessmann; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

6.  Image reconstruction by regularized nonlinear inversion--joint estimation of coil sensitivities and image content.

Authors:  Martin Uecker; Thorsten Hohage; Kai Tobias Block; Jens Frahm
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

7.  Accelerating SENSE using compressed sensing.

Authors:  Dong Liang; Bo Liu; Jiunjie Wang; Leslie Ying
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

8.  Online real-time reconstruction of adaptive TSENSE with commodity CPU/GPU hardware.

Authors:  Sébastien Roujol; Baudouin Denis de Senneville; Erkki Vahala; Thomas Sangild Sørensen; Chrit Moonen; Mario Ries
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

9.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

10.  Parallel imaging with nonlinear reconstruction using variational penalties.

Authors:  Florian Knoll; Christian Clason; Kristian Bredies; Martin Uecker; Rudolf Stollberger
Journal:  Magn Reson Med       Date:  2011-06-27       Impact factor: 4.668

View more
  66 in total

1.  Trajectory Auto-Corrected image reconstruction.

Authors:  Julianna D Ianni; William A Grissom
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

2.  Augmented Lagrangian with variable splitting for faster non-Cartesian L1-SPIRiT MR image reconstruction.

Authors:  Daniel S Weller; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-10-09       Impact factor: 10.048

3.  Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction.

Authors:  Tao Zhang; Shilpy Chowdhury; Michael Lustig; Richard A Barth; Marcus T Alley; Thomas Grafendorfer; Paul D Calderon; Fraser J L Robb; John M Pauly; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2013-10-11       Impact factor: 4.813

Review 4.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

5.  An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging.

Authors:  Guobin Li; Jürgen Hennig; Esther Raithel; Martin Büchert; Dominik Paul; Jan G Korvink; Maxim Zaitsev
Journal:  MAGMA       Date:  2015-02-26       Impact factor: 2.310

6.  Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark J Murphy; Shreyas S Vasanawala
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

7.  High spatial resolution compressed sensing (HSPARSE) functional MRI.

Authors:  Zhongnan Fang; Nguyen Van Le; ManKin Choy; Jin Hyung Lee
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

8.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

9.  Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE.

Authors:  Sen Jia; Lei Zhang; Lijie Ren; Yulong Qi; Jinhao Ly; Na Zhang; Ye Li; Xin Liu; Hairong Zheng; Dong Liang; Yiu-Cho Chung
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

10.  Sparsity-promoting calibration for GRAPPA accelerated parallel MRI reconstruction.

Authors:  Daniel S Weller; Jonathan R Polimeni; Leo Grady; Lawrence L Wald; Elfar Adalsteinsson; Vivek K Goyal
Journal:  IEEE Trans Med Imaging       Date:  2013-04-09       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.