| Literature DB >> 24325886 |
Mariana Bulhoes Galvão1, Matteo Camporesi, André Tortamano, Gladys Cristina Dominguez, Efisio Defraia.
Abstract
BACKGROUND: The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24325886 PMCID: PMC4384920 DOI: 10.1186/2196-1042-14-9
Source DB: PubMed Journal: Prog Orthod ISSN: 1723-7785 Impact factor: 2.750
Figure 1Experimental model with misaligned canine bracket.
Figure 2Graphical representation of the forces analyzed. The different colored lines in the graph represent the four tests.
Figure 3In the upward movement, the Instron machine analyzes the frictional forces ( ) and elastic forces ( ).
Figure 4When movement is stopped, the Instron machine analyzes the same forces, but f shows opposite direction.
Descriptive statistics for the frictional forces (Newton)
| SENT (in.) | CM (mm) | Inspire Ice-CEL | Inspire Ice-NCEL | Radiance-CEL | Radiance-NCEL | Pure CEL | Pure NCEL | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | SD | Mean | SD | Mean | SD | Mean | SD | ||
| 0.12 | 1.5 | 0.177 | 0.028 | 0.045 | 0.005 | 0.147 | 0.021 | 0.029 | 0.013 | 0.100 | 0.025 | 0.059 | 0.011 |
| 3.0 | 0.279 | 0.016 | 0.178 | 0.021 | 0.361 | 0.026 | 0.187 | 0.026 | 0.248 | 0.038 | 0.184 | 0.014 | |
| 4.5 | 0.362 | 0.033 | 0.212 | 0.025 | 0.467 | 0.041 | 0.279 | 0.054 | 0.327 | 0.031 | 0.236 | 0.026 | |
| 6.0 | 0.474 | 0.108 | 0.256 | 0.025 | 0.510 | 0.026 | 0.290 | 0.042 | 0.415 | 0.049 | 0.301 | 0.028 | |
| 0.14 | 1.5 | 0.175 | 0.018 | 0.088 | 0.006 | 0.206 | 0.020 | 0.095 | 0.016 | 0.145 | 0.019 | 0.062 | 0.015 |
| 3.0 | 0.335 | 0.013 | 0.226 | 0.009 | 0.471 | 0.020 | 0.318 | 0.014 | 0.331 | 0.010 | 0.214 | 0.005 | |
| 4.5 | 0.429 | 0.018 | 0.275 | 0.017 | 0.647 | 0.063 | 0.441 | 0.041 | 0.444 | 0.011 | 0.323 | 0.047 | |
| 6.0 | 0.496 | 0.024 | 0.354 | 0.027 | 0.773 | 0.113 | 0.481 | 0.106 | 0.422 | 0.056 | 0.348 | 0.028 | |
CM canine misalignment, SENT superelastic nickel titanium wire, CEL conventional elastomeric ligatures, NCEL nonconventional elastomeric ligatures.
Statistical between-group comparisons (ANOVA on ranks with Tukey's tests)
| SENT (in.) | CM (mm) |
| ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Inspire Ice-CEL vs Inspire Ice-NCEL | Radiance-CEL vs Radiance-NCEL | Pure CEL vs Pure NCEL | Inspire Ice-CEL vs Pure CEL | Inspire Ice-CEL vs Radiance-CEL | Radiance-CEL vs Pure CEL | Inspire Ice-NCEL vs Pure NCEL | Inspire Ice-NCEL vs Radiance-NCEL | Radiance-NCEL vs Pure NCEL | ||
| 0.12 | 1.5 | <0.001 | <0.001 | 0.955 | 0.004 | >0.999 | 0.781 | >0.999 | >0.999 | >0.999 |
| 3.0 | <0.001 | <0.001 | 0.093 | >0.999 | 0.001 | <0.001 | >0.999 | >0.999 | >0.999 | |
| 4.5 | <0.001 | <0.001 | <0.001 | 0.999 | <0.001 | <0.001 | >0.999 | 0.046 | 0.915 | |
| 6.0 | <0.001 | <0.001 | <0.001 | 0.225 | 0.995 | <0.001 | 0.884 | 0.999 | >0.999 | |
| 0.14 | 1.5 | <0.001 | <0.001 | 0.001 | >0.999 | >0.999 | 0.138 | >0.999 | >0.999 | 0.999 |
| 3.0 | <0.001 | <0.001 | <0.001 | >0.999 | <0.001 | <0.001 | >0.999 | <0.001 | <0.001 | |
| 4.5 | <0.001 | <0.001 | <0.001 | >0.999 | <0.001 | <0.001 | 0.745 | <0.001 | <0.001 | |
| 6.0 | <0.001 | <0.001 | 0.008 | 0.009 | <0.001 | <0.001 | >0.999 | <0.001 | <0.001 | |
CM canine misalignment, SENT superelastic nickel titanium wire, CEL conventional elastomeric ligatures, NCEL nonconventional elastomeric ligatures.