Literature DB >> 2378317

Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys.

S Kapila1, P V Angolkar, M G Duncanson, R S Nanda.   

Abstract

This investigation was designed to determine the effects of wire size and alloy on frictional force generated between bracket and wire during in vitro translatory displacement of bracket relative to wire. Stainless steel (SS), cobalt-chromium (Co-Cr), nickel-titanium (NiTi), and beta-titanium (beta-Ti) wires of several sizes were tested in narrow single (0.050-inch), medium twin (0.130-inch) and wide twin (0.180-inch) stainless steel brackets in both 0.018- and 0.022-inch slots. The wires were ligated into the brackets with elastomeric ligatures. Bracket movement along the wire was implemented by means of a mechanical testing instrument, and frictional forces were measured by a compression cell and recorded on an X-Y recorder. beta-Ti and NiTi wires generated greater amounts of frictional forces than SS or Co-Cr wires did for most wire sizes. Increase in wire size generally resulted in increased bracket-wire friction. The wire size-alloy interaction on the magnitude of bracket-wire friction was statistically significant (p less than 0.005). With most wire sizes and alloys, narrow single brackets were associated with lower amounts of friction than wider brackets were. The levels of frictional forces in 0.018-inch brackets ranged from 49 gm with 0.016-inch SS wires in narrow single brackets to 336 gm with 0.017 x 0.025-inch beta-Ti wires in wide twin brackets. Similarly for 0.022-inch brackets, frictional forces ranged from 40 gm with 0.018-inch SS wires in narrow single brackets to 222 gm with 0.019 x 0.025-inch NiTi wires in wide twin brackets.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2378317     DOI: 10.1016/0889-5406(90)70005-W

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  49 in total

1.  The influence of bracket design on frictional losses in the bracket/arch wire system.

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  In vitro evaluation of frictional force of a novel elastic bendable orthodontic wire.

Authors:  Megumi Takada; Akira Nakajima; Shingo Kuroda; Shinya Horiuchi; Noriyoshi Shimizu; Eiji Tanaka
Journal:  Angle Orthod       Date:  2018-05-25       Impact factor: 2.079

3.  Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations.

Authors:  Maria Regina Guerra Monteiro; Licinio Esmeraldo da Silva; Carlos Nelson Elias; Oswaldo de Vasconcellos Vilella
Journal:  J Appl Oral Sci       Date:  2014-06       Impact factor: 2.698

4.  Management of dental trauma: development of a 2D data acquisition system to evaluate passivity of dental splints.

Authors:  J Prévost; M Nivoit; Y Granjon
Journal:  Med Biol Eng Comput       Date:  1997-07       Impact factor: 2.602

5.  First order couples induced by nickel-titanium archwires featuring an electrochemically refined surface during simulated rotation of teeth.

Authors:  Leif Johannessen; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

6.  Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

Authors:  Sujeet Kumar; Shamsher Singh; Rani Hamsa P R; Sameer Ahmed; Apoorva Bhatnagar; Manreet Sidhu; Pramod Shetty
Journal:  J Clin Diagn Res       Date:  2014-05-15

7.  Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors:  Matteo Camporesi; Mariana Bulhoes Galvão; André Tortamano; Gladys Cristina Dominguez; Nicolò Defraia; Efisio Defraia; Lorenzo Franchi
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

8.  Friction between Archwire of Different Sizes, Cross Section, Alloy and Brackets Ligated with Different Brands of Low Friction Elastic Ligatures- An Invitro Study.

Authors:  Bhushan Patil; Neeraj Suresh Patil; Veerendra Virupaxappa Kerudi; Shrikant Shrinivas Chitko; Amit Ratanlal Maheshwari; Harshal Ashok Patil; Nikhita Popatrao Pekhale; Pawankumar Dnyandeo Tekale
Journal:  J Clin Diagn Res       Date:  2016-04-01

9.  Characterizing constraining forces in the alignment phase of orthodontic treatment.

Authors:  Christopher G Gibson; Feng-Chang Lin; Ceib Phillips; Alex Edelman; Ching-Chang Ko
Journal:  Angle Orthod       Date:  2017-09-25       Impact factor: 2.079

10.  [Frictional forces and movement dynamics in the mesialization of the second molar after the extraction of the sixth-year molar. An in-vitro study].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1993-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.