Accuracy of orthodontic force and tooth movement measurements.

D Lundgren1, P Owman-Moll, J Kurol, B Mårtensson.   

Abstract

This study was designed to test the accuracy of measurement methods for assessment of force and tooth movement in orthodontic procedures. Daily in vivo measurements of the force produced by activated archwires showed that the initial force declined substantially (by 20 per cent of mean value) within 3 days. Both the 'trueness' (validity) and precision of the force measurements, obtained with a strain gauge, were found to be high (SD values were 1.0 cN and 0.4 cN, respectively). Horizontal tooth movements were measured with three different instruments: a slide calliper, a co-ordinate measuring machine, and laser measuring equipment based on holograms. There was a good level of agreement between these methods. This was also confirmed by calibration data. The precision of the methods was (SD values) 0.06, 0.07, and 0.13 mm, respectively. The benefits of the use of the co-ordinate measuring machine are obvious, since it can measure tooth movements in relation to reference planes in all directions.

Entities:  

Mesh:

Year:  1996        PMID: 8894157     DOI: 10.1179/bjo.23.3.241

Source DB:  PubMed          Journal:  Br J Orthod        ISSN: 0301-228X


  4 in total

1.  Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires.

Authors:  Madhur Upadhyay; Raja Shah; Sachin Agarwal; Meenakshi Vishwanath; Po-Jung Chen; Takafumi Asaki; Donald Peterson
Journal:  J Vis Exp       Date:  2018-07-24       Impact factor: 1.355

2.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

3.  Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures.

Authors:  Mariana Bulhoes Galvão; Matteo Camporesi; André Tortamano; Gladys Cristina Dominguez; Efisio Defraia
Journal:  Prog Orthod       Date:  2013-05-23       Impact factor: 2.750

4.  Stainless steel and NiTi torque archwires and apical root resorption.

Authors:  Andrea Wichelhaus; Marc Dulla; Hisham Sabbagh; Uwe Baumert; Thomas Stocker
Journal:  J Orofac Orthop       Date:  2020-09-01       Impact factor: 1.938