Literature DB >> 24317086

Haemodynamic outcome at four-dimensional flow magnetic resonance imaging following valve-sparing aortic root replacement with tricuspid and bicuspid valve morphology.

Edouard Semaan1, Michael Markl, S Chris Malaisrie, Alex Barker, Bradley Allen, Patrick McCarthy, James C Carr, Jeremy D Collins.   

Abstract

OBJECTIVE: To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size.
METHODS: Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0-2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration.
RESULTS: Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow acceleration as a surrogate measure of reduced aortic compliance.
CONCLUSIONS: VSARR restored a cohesive flow pattern independent of native valve morphology but resulted in increased peak velocities throughout the aorta. 4D flow MRI methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing VSARR.

Entities:  

Keywords:  4D flow MRI; Aortic aneurysm; Bicuspid aortic valve

Mesh:

Year:  2013        PMID: 24317086      PMCID: PMC3982920          DOI: 10.1093/ejcts/ezt526

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  24 in total

1.  Opening and closing characteristics of the aortic valve after different types of valve-preserving surgery.

Authors:  R G Leyh; C Schmidtke; H H Sievers; M H Yacoub
Journal:  Circulation       Date:  1999-11-23       Impact factor: 29.690

2.  Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve-sparing surgery.

Authors:  John-Peder Escobar Kvitting; Tino Ebbers; Lars Wigström; Jan Engvall; Christian L Olin; Ann F Bolger
Journal:  J Thorac Cardiovasc Surg       Date:  2004-06       Impact factor: 5.209

3.  Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement.

Authors:  Michael Markl; Mary T Draney; D Craig Miller; Jonathan M Levin; Eric E Williamson; Norbert J Pelc; David H Liang; Robert J Herfkens
Journal:  J Thorac Cardiovasc Surg       Date:  2005-08       Impact factor: 5.209

4.  Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping.

Authors:  P J Kilner; G Z Yang; R H Mohiaddin; D N Firmin; D B Longmore
Journal:  Circulation       Date:  1993-11       Impact factor: 29.690

5.  Composite valve graft versus separate aortic valve and ascending aortic replacement: is there still a role for the separate procedure?

Authors:  K L Yun; D C Miller; J I Fann; R S Mitchell; R C Robbins; K A Moore; P E Oyer; E B Stinson; N E Shumway; B A Reitz
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

6.  Aortic root dilatation in young men with normally functioning bicuspid aortic valves.

Authors:  S Nistri; M D Sorbo; M Marin; M Palisi; R Scognamiglio; G Thiene
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

7.  Association between bicuspid aortic valve phenotype and patterns of valvular dysfunction and bicuspid aortopathy: comprehensive evaluation using MDCT and echocardiography.

Authors:  Joon-Won Kang; Hae Geun Song; Dong Hyun Yang; Seunghee Baek; Dae-Hee Kim; Jong-Min Song; Duk-Hyun Kang; Tae-Hwan Lim; Jae-Kwan Song
Journal:  JACC Cardiovasc Imaging       Date:  2013-02

8.  Effect of an inelastic aortic synthetic vascular graft on exercise hemodynamics.

Authors:  S Y Kim; T J Hinkamp; W R Jacobs; R C Lichtenberg; H Posniak; R Pifarré
Journal:  Ann Thorac Surg       Date:  1995-04       Impact factor: 4.330

9.  An aortic valve-sparing operation for patients with aortic incompetence and aneurysm of the ascending aorta.

Authors:  T E David; C M Feindel
Journal:  J Thorac Cardiovasc Surg       Date:  1992-04       Impact factor: 5.209

Review 10.  Post-stenotic aortic dilatation.

Authors:  Emma Wilton; Marjan Jahangiri
Journal:  J Cardiothorac Surg       Date:  2006-03-03       Impact factor: 1.637

View more
  11 in total

1.  Reduction of aberrant aortic haemodynamics following aortic root replacement with a mechanical valved conduit.

Authors:  Eric J Keller; S Chris Malaisrie; Jane Kruse; Patrick M McCarthy; James C Carr; Michael Markl; Alex J Barker; Jeremy D Collins
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-05-30

2.  Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

Authors:  Susanne Schnell; Danielle A Smith; Alex J Barker; Pegah Entezari; Amir R Honarmand; Maria L Carr; S Chris Malaisrie; Patrick M McCarthy; Jeremy Collins; James C Carr; Michael Markl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-07-26       Impact factor: 6.875

Review 3.  New imaging tools in cardiovascular medicine: computational fluid dynamics and 4D flow MRI.

Authors:  Keiichi Itatani; Shohei Miyazaki; Tokoki Furusawa; Satoshi Numata; Sachiko Yamazaki; Kazuki Morimoto; Rina Makino; Hiroko Morichi; Teruyasu Nishino; Hitoshi Yaku
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-09-19

Review 4.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

5.  Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit.

Authors:  Jeremy D Collins; Edouard Semaan; Alex Barker; Patrick M McCarthy; James C Carr; Michael Markl; S Chris Malaisrie
Journal:  Ann Thorac Surg       Date:  2015-07-23       Impact factor: 4.330

6.  4D flow characterization of aortic blood flow after valve sparing root reimplantation procedure.

Authors:  Nicola Galea; Filippo Piatti; Christopher Lau; Francesco Sturla; Luca Weltert; Iacopo Carbone; Ruggero De Paulis; Mario Gaudino; Leonard N Girardi
Journal:  J Vis Surg       Date:  2018-05-09

7.  Blood flow energy loss: a predictor for the recovery of left ventricular function after bioprosthetic aortic valve replacement.

Authors:  Yu Hohri; Keiichi Itatani; Satoshi Numata; Sachiko Yamazaki; Shohei Miyazaki; Teruyasu Nishino; Hitoshi Yaku
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-08-18

8.  Differential flow improvements after valve replacements in bicuspid aortic valve disease: a cardiovascular magnetic resonance assessment.

Authors:  Malenka M Bissell; Margaret Loudon; Aaron T Hess; Victoria Stoll; Elizabeth Orchard; Stefan Neubauer; Saul G Myerson
Journal:  J Cardiovasc Magn Reson       Date:  2018-02-08       Impact factor: 5.364

9.  4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease.

Authors:  Alexander Lenz; Johannes Petersen; Christoph Riedel; Julius M Weinrich; Hendrik Kooijman; Bjoern P Schoennagel; Gerhard Adam; Yskert von Kodolitsch; Hermann Reichenspurner; Evaldas Girdauskas; Peter Bannas
Journal:  J Cardiovasc Magn Reson       Date:  2020-04-30       Impact factor: 5.364

10.  Long-Term Comparison Between Pulmonary Homograft Versus Bioprosthesis for Pulmonary Valve Replacement in Tetralogy of Fallot.

Authors:  Lucia Cocomello; Marco Meloni; Filippo Rapetto; Mai Baquedano; Maria Victoria Ordoñez; Giovanni Biglino; Chiara Bucciarelli-Ducci; Andrew Parry; Serban Stoica; Massimo Caputo
Journal:  J Am Heart Assoc       Date:  2019-12-16       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.