Literature DB >> 7695428

Effect of an inelastic aortic synthetic vascular graft on exercise hemodynamics.

S Y Kim1, T J Hinkamp, W R Jacobs, R C Lichtenberg, H Posniak, R Pifarré.   

Abstract

This study compared aortic input impedance characteristics between patients with aortic interposition Dacron grafts placed for traumatic aortic injury and normal age-matched control subjects. All subjects were examined at rest and after treadmill exercise. Magnetic resonance imaging was conducted to rule out anatomic (stenosis) effects. Exercise increased characteristic impedance (ie, reduced aortic distensibility) by 29% and decreased total systemic arterial compliance by 21% in the patient group, whereas the normal control group showed insignificant change in these variables after exercise. Peripheral pressure wave reflection was reduced substantially with exercise (27%) in the control group, with much less reduction observed in the patient group. These abnormal vascular hemodynamics were associated with significantly high cardiac energetic costs in the patient group. A plausible explanation for the observed differences lies in the exaggerated vascular impedance mismatch between compliant aorta and inelastic graft, when cardiac output increases dramatically.

Entities:  

Mesh:

Year:  1995        PMID: 7695428     DOI: 10.1016/0003-4975(95)00068-v

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  10 in total

1.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

2.  Haemodynamic outcome at four-dimensional flow magnetic resonance imaging following valve-sparing aortic root replacement with tricuspid and bicuspid valve morphology.

Authors:  Edouard Semaan; Michael Markl; S Chris Malaisrie; Alex Barker; Bradley Allen; Patrick McCarthy; James C Carr; Jeremy D Collins
Journal:  Eur J Cardiothorac Surg       Date:  2013-12-06       Impact factor: 4.191

3.  Long-term follow-up of reduction ascending aortoplasty with autologous partial wrapping: for which patient is waistcoat aortoplasty best suited?

Authors:  Alessandro Della Corte; Marisa De Feo; Ciro Bancone; Raffaela Provenzano; Salvatore Giordano; Marianna Buonocore; Gianantonio Nappi; Maurizio Cotrufo
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-11-15

4.  External aortic root support: a histological and mechanical study in sheep.

Authors:  Peter Verbrugghe; Erik Verbeken; John Pepper; Tom Treasure; Bart Meyns; Bart Meuris; Paul Herijgers; Filip Rega
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-26

5.  Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit.

Authors:  Jeremy D Collins; Edouard Semaan; Alex Barker; Patrick M McCarthy; James C Carr; Michael Markl; S Chris Malaisrie
Journal:  Ann Thorac Surg       Date:  2015-07-23       Impact factor: 4.330

Review 6.  Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries.

Authors:  Charanpreet Singh; Cynthia S Wong; Xungai Wang
Journal:  J Funct Biomater       Date:  2015-06-30

Review 7.  Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is Gold.

Authors:  Cristiano Spadaccio; Francesco Nappi; Nawwar Al-Attar; Fraser W Sutherland; Christophe Acar; Antonio Nenna; Marcella Trombetta; Massimo Chello; Alberto Rainer
Journal:  J Cardiovasc Transl Res       Date:  2016-05-31       Impact factor: 4.132

Review 8.  Hemodynamic Profiles Before and After Surgery in Bicuspid Aortic Valve Disease-A Systematic Review of the Literature.

Authors:  Daniel G W Cave; Hannah Panayiotou; Malenka M Bissell
Journal:  Front Cardiovasc Med       Date:  2021-03-24

9.  Influence of shape-memory stent grafts on local aortic compliance.

Authors:  J Concannon; K M Moerman; N Hynes; S Sultan; J P McGarry
Journal:  Biomech Model Mechanobiol       Date:  2021-09-19

10.  Total aortic arch replacement: superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses.

Authors:  Alexander Weymann; Tamás Radovits; Bastian Schmack; Sevil Korkmaz; Shiliang Li; Nicole Chaimow; Ines Pätzold; Peter Moritz Becher; István Hartyánszky; Pál Soós; Gergő Merkely; Balázs Tamás Németh; Roland Istók; Gábor Veres; Béla Merkely; Konstantin Terytze; Matthias Karck; Gábor Szabó
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.