Literature DB >> 24187356

Dislocation following total hip replacement: causes and cures.

P J Brooks1.   

Abstract

Dislocation is one of the most common causes of patient and surgeon dissatisfaction following hip replacement and to treat it, the causes must first be understood. Patient factors include age greater than 70 years, medical comorbidities, female gender, ligamentous laxity, revision surgery, issues with the abductors, and patient education. Surgeon factors include the annual quantity of procedures and experience, the surgical approach, adequate restoration of femoral offset and leg length, component position, and soft-tissue or bony impingement. Implant factors include the design of the head and neck region, and so-called skirts on longer neck lengths. There should be offset choices available in order to restore soft-tissue tension. Lipped liners aid in gaining stability, yet if improperly placed may result in impingement and dislocation. Late dislocation may result from polyethylene wear, soft-tissue destruction, trochanteric or abductor disruption and weakness, or infection. Understanding the causes of hip dislocation facilitates prevention in a majority of instances. Proper pre-operative planning includes the identification of patients with a high offset in whom inadequate restoration of offset will reduce soft-tissue tension and abductor efficiency. Component position must be accurate to achieve stability without impingement. Finally, patient education cannot be over-emphasised, as most dislocations occur early, and are preventable with proper instructions.

Entities:  

Keywords:  Hip replacement; dislocation; impingement; malposition; offset

Mesh:

Year:  2013        PMID: 24187356     DOI: 10.1302/0301-620X.95B11.32645

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  25 in total

1.  Unstable hip arthroplasties. A prospective cohort study on seventy dislocating hips followed up for four years.

Authors:  Olle Wallner; André Stark; Olle Muren; Thomas Eisler; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-11-13       Impact factor: 3.075

2.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

3.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

4.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

5.  Cup alignment in total hip arthroplasty using the muscle-sparing modified Watson-Jones approach-comparison between lateral and supine positions.

Authors:  Yuichi Kishimura; Yukihide Minoda; Shigekazu Mizokawa; Ryo Sugama; Yoichi Ohta; Hiroaki Nakamura
Journal:  Int Orthop       Date:  2019-03-06       Impact factor: 3.075

6.  Soft tissue restricts impingement-free mobility in total hip arthroplasty.

Authors:  Michael Woerner; Markus Weber; Ernst Sendtner; Robert Springorum; Michael Worlicek; Benjamin Craiovan; Joachim Grifka; Tobias Renkawitz
Journal:  Int Orthop       Date:  2016-05-06       Impact factor: 3.075

7.  Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Authors:  Ji-Hyo Hwang; Sang-Min Kim; Kwang-Jun Oh; Yeesuk Kim
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

8.  Dual-Mobility Cup Total Hip Arthroplasty for Displaced Femoral Neck Fractures: A Retrospective Study With a Median Follow-Up of 5 Years.

Authors:  Zhenfa Zhang; Guixing Xu; Lei Cao; Wei Sun; Xianshang Zeng; Nana Xiong; Shuxin Wang; Weiguang Yu; Qilong Liu; Huanyi Lin
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-04-30

9.  Deep Learning Artificial Intelligence Model for Assessment of Hip Dislocation Risk Following Primary Total Hip Arthroplasty From Postoperative Radiographs.

Authors:  Pouria Rouzrokh; Taghi Ramazanian; Cody C Wyles; Kenneth A Philbrick; Jason C Cai; Michael J Taunton; Hilal Maradit Kremers; David G Lewallen; Bradley J Erickson
Journal:  J Arthroplasty       Date:  2021-02-16       Impact factor: 4.435

10.  Nerve palsy, dislocation and revision rate among the approaches for total hip arthroplasty: a Bayesian network meta-analysis.

Authors:  F Migliorini; A Trivellas; J Eschweiler; A Driessen; F Lessi; M Tingart; P Aretini
Journal:  Musculoskelet Surg       Date:  2020-05-05