Literature DB >> 28986663

Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series.

Ji-Hyo Hwang1, Sang-Min Kim2, Kwang-Jun Oh3, Yeesuk Kim4.   

Abstract

BACKGROUND: The purpose of this study was to investigate the incidence of dislocation and specific complications of the dual-mobility cup.
METHODS: The arthroplasties involved 167 hips in 165 patients; 51 hips (30.5%) were in men and 116 (69.4%) were in women. The active articulation E1® dual-mobility cup (Biomet, Warsaw, IN, USA) was used, and the surgical approach was posterolateral in 120 hips and anterolateral in 47 hips.
RESULTS: Four (2.3%) dislocations were observed. Mean time of dislocation was 30.5 days post-operatively. Three incomplete reductions occurred during closed reduction. When comparing parameters between dislocation and no-dislocation groups, there were no differences in patient and surgical parameters. However, all dislocations occurred in patients with femoral neck fractures and in the posterolateral approach group.
CONCLUSION: The incidence of dislocation in total hip arthroplasty (THA) using a dual-mobility cup was acceptable, and cup diameter of the dislocation group was substantially larger than that of no-dislocation group. Based on clinical outcomes of our study, we conclude that the dual-mobility cup is a reliable option in THA, and further studies are necessary.

Entities:  

Keywords:  Dislocation; Dual mobility cup; Hip; Total hip arthroplasty

Mesh:

Year:  2017        PMID: 28986663     DOI: 10.1007/s00264-017-3660-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  40 in total

1.  Is a cementless dual mobility socket in primary THA a reasonable option?

Authors:  Moussa Hamadouche; Hervé Arnould; Bertrand Bouxin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Contemporary dual-mobility cup regional and private register: methodology and results.

Authors:  André Ferreira; Jean-Louis Prudhon; Régis Verdier; Jean-Marc Puch; Loys Descamps; Guy Dehri; Marcel Remi; Jacques H Caton
Journal:  Int Orthop       Date:  2017-02-14       Impact factor: 3.075

3.  Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.

Authors:  S Leclercq; J Y Benoit; J P de Rosa; E Tallier; C Leteurtre; P H Girardin
Journal:  Orthop Traumatol Surg Res       Date:  2013-10-29       Impact factor: 2.256

4.  Intraprosthetic dislocation: a specific complication of the dual-mobility system.

Authors:  Remi Philippot; Bertrand Boyer; Frederic Farizon
Journal:  Clin Orthop Relat Res       Date:  2012-10-10       Impact factor: 4.176

5.  Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up : A prospective and comparative series.

Authors:  Jean-Marc Puch; Guy Derhi; Loys Descamps; Régis Verdier; Jacques H Caton
Journal:  Int Orthop       Date:  2016-11-08       Impact factor: 3.075

6.  A comparison of the posterolateral and anterolateral approaches to total hip arthroplasty.

Authors:  J M Roberts; F H Fu; E J McClain; A B Ferguson
Journal:  Clin Orthop Relat Res       Date:  1984 Jul-Aug       Impact factor: 4.176

7.  Assessment of Damage on a Dual Mobility Acetabular System.

Authors:  Michele R D'Apuzzo; Chelsea N Koch; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Geoffrey H Westrich
Journal:  J Arthroplasty       Date:  2016-01-30       Impact factor: 4.757

8.  Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty.

Authors:  Daniel J Berry; Marius von Knoch; Cathy D Schleck; William S Harmsen
Journal:  J Bone Joint Surg Am       Date:  2005-11       Impact factor: 5.284

9.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

Review 10.  Total hip arthroplasty versus hemiarthroplasty for displaced femoral neck fractures in the healthy elderly: a meta-analysis and systematic review of randomized trials.

Authors:  Paul T P W Burgers; Arnoud R Van Geene; Michel P J Van den Bekerom; Esther M M Van Lieshout; Bastiaan Blom; Ilyas S Aleem; M Bhandari; Rudolf W Poolman
Journal:  Int Orthop       Date:  2012-05-24       Impact factor: 3.075

View more
  6 in total

1.  Letter to the editor on "Dislocations after use of dual-mobility cups in cementless primary total hip arthroplasty: prospective multicentre series" by Hwang et al.

Authors:  Anthony Viste; Julien Girard; Jean-Alain Epinette; Henri Migaud; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2017-12-12       Impact factor: 3.075

2.  Contemporary cemented versus uncemented hemiarthroplasty for the treatment of displaced intracapsular hip fractures: a meta-analysis of forty-two thousand forty-six hips.

Authors:  Mohamed A Imam; Mohamed S A Shehata; Ahmed Elsehili; Mahmoud Morsi; Alexander Martin; Muhammad Shawqi; Florian Grubhofer; Nish Chirodian; Ali Narvani; Lukas Ernstbrunner
Journal:  Int Orthop       Date:  2019-03-27       Impact factor: 3.075

3.  Do Dual-mobility Cups Reduce Revision Risk in Femoral Neck Fractures Compared With Conventional THA Designs? An International Meta-analysis of Arthroplasty Registries.

Authors:  John E Farey; James Masters; Alana R Cuthbert; Pernille Iversen; Liza N van Steenbergen; Heather A Prentice; Sam Adie; Adrian Sayers; Michael R Whitehouse; Elizabeth W Paxton; Matthew L Costa; Søren Overgaard; Cecilia Rogmark; Ola Rolfson; Ian A Harris
Journal:  Clin Orthop Relat Res       Date:  2022-06-16       Impact factor: 4.755

Review 4.  Causes of and treatment options for dislocation following total hip arthroplasty.

Authors:  Yian Lu; Haijun Xiao; Feng Xue
Journal:  Exp Ther Med       Date:  2019-07-03       Impact factor: 2.447

5.  Use of a modular hip dual-mobility articulation in patients with high risk of dislocation: a relatively small-sized acetabulum in Asian patients may limit its use.

Authors:  Ping Keung Chan; Sum Lik Cheung; Kar Hei Lam; Wing Chiu Fung; Vincent Wai Kwan Chan; Amy Cheung; Man Hong Cheung; Henry Fu; Chun Hoi Yan; Kwong Yuen Chiu
Journal:  Arthroplasty       Date:  2021-05-03

6.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

  6 in total