Fig. 1Time flow of study drug administration. The study drug was administered over 1 min, ≥5 min after nitrate drug administration. CCTA coronary computed tomography angiography, CT computed tomography
Imaging conditions for each type of computed tomography equipment
| Imaging condition | Siemens (64) | Toshiba (64) | Toshiba (320) | GE (64) | Philips (64) |
|---|---|---|---|---|---|
| Tube voltage (kv) | 120 | 120 | 120 | 120 | 120 |
| Tube current (mA) | 770–850 | 400–500 | 400–580 | 500–750 | 800–1,000 |
| Collimation (row × mm) | 32 × 6 | 64 × 0.5 | (200–320) × 0.5 | 64 × 0.625 | 64 × 0.625 |
| Rotation speed of X-ray tube (s/rot) | 0.33 | 0.35 | 0.35 | 0.35 | 0.42 |
| Helical pitch | ≤0.2 | ≤0.2 | – | ≤0.24 | ≤0.2 |
| Field of view (mm) | 200 | 200 | 200 | 200 | 200 |
Fig. 2Flow diagram of subjects
Baseline patient characteristics and coronary computed tomography angiography conditions
| Parameter | Landiolol hydrochloride group | Placebo group |
|
|---|---|---|---|
| Patient characteristics | |||
| No. of patients | 130 | 128 | |
| Sex (male/female), | 81/49 (62.3/37.7) | 79/49 (61.7/38.3) | 0.9224a |
| Age (years), mean ± SD | 65.0 ± 11.1 | 64.4 ± 11.2 | 0.3637b |
| Height (cm), mean ± SD | 159.83 ± 9.06 | 160.33 ± 9.84 | 0.5883b |
| Body weight (kg), mean ± SD | 63.073 ± 11.719 | 63.811 ± 13.378 | 0.8286b |
| Subjects with angina symptoms, | 117 (90.7) | 113 (89.7) | 0.7852a |
| Heart rate (beats/min), mean ± SD | 77.6 ± 9.5 | 76.9 ± 8.9 | 0.8251b |
| Systolic blood pressure (mmHg), mean ± SD | 129.3 ± 20.0 | 131.1 ± 20.2 | 0.4225b |
| Diastolic blood pressure (mmHg), mean ± SD | 73.4 ± 12.1 | 74.7 ± 11.6 | 0.2877b |
| CCTA conditions | |||
| CT equipment, | |||
| Siemens (64) | 77 (59.3) | 74 (58.3) | 0.9843a |
| Toshiba (64) | 13 (10.1) | 14 (11.0) | |
| Toshiba (320) | 14 (10.9) | 12 (9.4) | |
| GE (64) | 12 (9.3) | 12 (9.4) | |
| Philips (64) | 13 (10.1) | 15 (11.8) | |
| Time from completion of study drug administration to initiation of imaging (s), mean ± SD | 320.7 ± 46.5 | 319.2 ± 40.3 | 0.9435b |
| Scanning time (s), mean ± SD | 10.9 ± 3.7 | 10.8 ± 3.4 | 0.6894b |
| Subjects by administration speed of contrast medium, | |||
| <3 mL/s | 11 (8.5) | 12 (9.4) | 0.5307b |
| 3.5–4.0 mL/s | 61 (47.3) | 54 (42.5) | |
| >4.0 mL/s | 57 (44.2) | 61 (48.0) | |
| Total dose of contrast medium and saline (mL), mean ± SD | 92.2 ± 13.1 | 93.7 ± 11.6 | 0.3669b |
CCTA coronary computed tomography angiography, CT computed tomography, SD standard deviation
aAssessed by Chi-squared (χ 2) test
bAssessed by Wilcoxon rank-sum test
Lowering proportion of heart rate and blood pressure at coronary computed tomography angiography
| Parameter | Evaluation timepoint | Landiolol hydrochloride group | Placebo group |
|---|---|---|---|
| Heart rate | Before administration | 77.6 ± 9.5 | 76.9 ± 8.9 |
| At CCTA | 62.6 ± 8.5 | 72.9 ± 12.0 | |
| Lowering proportion (%) | −19.1 ± 8.1 | −5.9 ± 9.7 | |
| Systolic blood pressure | Before administration | 129.3 ± 20.0 | 131.1 ± 20.2 |
| At CCTA | 125.1 ± 20.7 | 132.7 ± 20.7 | |
| Lowering proportion (%) | −2.6 ± 9.3 | 1.7 ± 10.2 |
Data are given as mean ± standard deviation
CCTA coronary computed tomography angiography
Distribution of image quality score
| Type of the reconstructed images | Reconstruction images at mid-diastole | Optimal reconstruction images | |||
|---|---|---|---|---|---|
| Analysis unit | Image quality score | Landiolol hydrochloride group | Placebo group | Landiolol hydrochloride group | Placebo group |
| By subject [ | 3 | 0 (0.0) | 0 (0.0) | 0 (0.0) | 0 (0.0) |
| 2 | 75 (68.2) | 42 (38.2) | 96 (81.4) | 64 (54.2) | |
| 1 | 35 (31.8) | 68 (61.8) | 22 (18.6) | 54 (45.8) | |
| Total | 110 | 110 | 118 | 118 | |
| ≥2 | 75 (68.2) | 42 (38.2) | 96 (81.4) | 64 (54.2) | |
|
| <0.0001a | <0.0001a | |||
| By coronary vessel [ | 3 | 44 (10.7) | 38 (9.2) | 55 (12.6) | 46 (10.5) |
| 2 | 316 (77.1) | 270 (65.5) | 358 (81.7) | 325 (73.9) | |
| 1 | 50 (12.2) | 104 (25.2) | 25 (5.7) | 69 (15.7) | |
| Total | 410 | 412 | 438 | 440 | |
| ≥2 | 360 (87.8) | 308 (74.8) | 413 (94.3) | 371 (84.3) | |
|
| <0.0001a | <0.0001a | |||
| By coronary segment [ | 3 | 166 (13.2) | 122 (9.5) | 228 (16.8) | 169 (12.5) |
| 2 | 1,003 (79.7) | 962 (75.0) | 1,098 (81.1) | 1,101 (81.4) | |
| 1 | 90 (7.1) | 199 (15.5) | 28 (2.1) | 83 (6.1) | |
| Total | 1,259 | 1,283 | 1,354 | 1,353 | |
| ≥2 | 1,169 (92.9) | 1,084 (84.5) | 1,326 (97.9) | 1,270 (93.9) | |
|
| <0.0001a | <0.0001a | |||
aVersus placebo [assessed by Chi-squared (χ 2 test)]
Fig. 4Mean ± standard deviation changes in blood pressure. Mean blood pressure showed a significant difference between the two groups, but the lowering proportion was limited, as shown in Table 3. CCTA coronary computed tomography angiography, CT computed tomography, *p < 0.05 vs. placebo (t test)
Fig. 5Relationship between diagnosable proportion and heart rate. There was a positive correlation between the diagnosable proportion and heart rate
Fig. 3Mean ± standard deviation changes in heart rate. Rotation speed of the X-ray tube was set at the maximum speed for each type of computed tomography equipment. CCTA coronary computed tomography angiography, CT computed tomography, *p < 0.05 vs. placebo (t test)