Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Petra C Guess1, Thaleia Vagkopoulou2, Yu Zhang3, Martin Wolkewitz4, Joerg R Strub2.   

Abstract

OBJECTIVES: The aim of the study was to evaluate the marginal and internal fit of heat-pressed and CAD/CAM fabricated all-ceramic onlays before and after luting as well as after thermo-mechanical fatigue.
MATERIALS AND METHODS: Seventy-two caries-free, extracted human mandibular molars were randomly divided into three groups (n=24/group). All teeth received an onlay preparation with a mesio-occlusal-distal inlay cavity and an occlusal reduction of all cusps. Teeth were restored with heat-pressed IPS-e.max-Press* (IP, *Ivoclar-Vivadent) and Vita-PM9 (VP, Vita-Zahnfabrik) as well as CAD/CAM fabricated IPS-e.max-CAD* (IC, Cerec 3D/InLab/Sirona) all-ceramic materials. After cementation with a dual-polymerising resin cement (VariolinkII*), all restorations were subjected to mouth-motion fatigue (98 N, 1.2 million cycles; 5°C/55°C). Marginal fit discrepancies were examined on epoxy replicas before and after luting as well as after fatigue at 200× magnification. Internal fit was evaluated by multiple sectioning technique. For the statistical analysis, a linear model was fitted with accounting for repeated measurements.
RESULTS: Adhesive cementation of onlays resulted in significantly increased marginal gap values in all groups, whereas thermo-mechanical fatigue had no effect. Marginal gap values of all test groups were equal after fatigue exposure. Internal discrepancies of CAD/CAM fabricated restorations were significantly higher than both press manufactured onlays.
CONCLUSIONS: Mean marginal gap values of the investigated onlays before and after luting as well as after fatigue were within the clinically acceptable range. Marginal fit was not affected by the investigated heat-press versus CAD/CAM fabrication technique. Press fabrication resulted in a superior internal fit of onlays as compared to the CAD/CAM technique. CLINICAL RELEVANCE: Clinical requirements of 100 μm for marginal fit were fulfilled by the heat-press as well as by the CAD/CAM fabricated all-ceramic onlays. Superior internal fit was observed with the heat-press manufacturing method. The impact of present findings on the clinical long-term behaviour of differently fabricated all-ceramic onlays warrants further investigation.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  All-ceramic materials; CAD/CAM; Internal fit; Marginal fit; Onlay restoration; Thermo-mechanical fatigue

Mesh:

Substances:

Year:  2013        PMID: 24161516      PMCID: PMC4450820          DOI: 10.1016/j.jdent.2013.10.002

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  61 in total

1.  IPS Empress inlays and onlays after four years--a clinical study.

Authors:  N Krämer; R Frankenberger; M Pelka; A Petschelt
Journal:  J Dent       Date:  1999-07       Impact factor: 4.379

2.  Leucite-reinforced glass ceramic inlays after six years: wear of luting composites.

Authors:  N Krämer; R Frankenberger
Journal:  Oper Dent       Date:  2000 Nov-Dec       Impact factor: 2.440

Review 3.  Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome.

Authors:  Siegward D Heintze
Journal:  J Adhes Dent       Date:  2007       Impact factor: 2.359

Review 4.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

Review 5.  Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.

Authors:  Noor A Nawafleh; Florian Mack; Jane Evans; John Mackay; Muhanad M Hatamleh
Journal:  J Prosthodont       Date:  2013-01-04       Impact factor: 2.752

6.  Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays.

Authors:  H Denissen; A Dozić; J van der Zel; M van Waas
Journal:  J Prosthet Dent       Date:  2000-11       Impact factor: 3.426

7.  The relationship between maximal bite force, bite force endurance, and facial morphology during growth. A cross-sectional study.

Authors:  S Kiliaridis; H Kjellberg; B Wenneberg; C Engström
Journal:  Acta Odontol Scand       Date:  1993-10       Impact factor: 2.331

8.  Fracture Modes in Curved Brittle Layers Subject to Concentrated Cyclic Loading in Liquid Environments.

Authors:  Jae-Won Kim; Van P Thompson; E Dianne Rekow; Yeon-Gil Jung; Yu Zhang
Journal:  J Mater Res       Date:  2009-03-01       Impact factor: 3.089

9.  Effect of water storage time and composite cement thickness on fatigue of a glass-ceramic trilayer system.

Authors:  Nelson R F A Silva; Grace M de Souza; Paulo G Coelho; Christian F J Stappert; Elizabeth A Clark; Elizabeth D Rekow; Van P Thompson
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-01       Impact factor: 3.368

10.  Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro.

Authors:  Marianne Federlin; Stephanie Krifka; Maximilian Herpich; Karl-Anton Hiller; Gottfried Schmalz
Journal:  Oper Dent       Date:  2007 May-Jun       Impact factor: 2.440

View more
  15 in total

1.  Microstructural development during heat treatment of a commercially available dental-grade lithium disilicate glass-ceramic.

Authors:  Angel L Ortiz; Oscar Borrero-López; Fernando Guiberteau; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

2.  A comparison of the marginal adaptation of composite overlays fabricated with silicone and an intraoral scanner.

Authors:  Carla García-Cuesta; Vicente Faus-Llácer; Álvaro Zubizarreta-Macho; René Botello-Torres; Vicente Faus-Matoses
Journal:  J Clin Exp Dent       Date:  2021-05-01

Review 3.  "Digitally Oriented Materials": Focus on Lithium Disilicate Ceramics.

Authors:  Fernando Zarone; Marco Ferrari; Francesco Guido Mangano; Renato Leone; Roberto Sorrentino
Journal:  Int J Dent       Date:  2016-08-18

4.  Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis.

Authors:  Jin-Young Park; So-Yeon Bae; Jae-Jun Lee; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

5.  Influence of Teeth Preparation Finishing on the Adaptation of Lithium Disilicate Crowns.

Authors:  Bruna Salamoni Sinhori; Mauro Amaral Caldeira de Andrada; Guilherme Carpena Lopes; Sylvio Monteiro Junior; Luiz Narciso Baratieri
Journal:  Int J Biomater       Date:  2017-03-23

6.  Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique.

Authors:  F D Oz; S Bolay
Journal:  Int J Dent       Date:  2018-04-26

7.  Surface morphology and mechanical properties of conventional and self-adhesive resin cements after aqueous aging.

Authors:  Yahui Pan; Xiaodong Xu; Fangfang Sun; Xiangfeng Meng
Journal:  J Appl Oral Sci       Date:  2018-11-08       Impact factor: 2.698

Review 8.  Current status on lithium disilicate and zirconia: a narrative review.

Authors:  Fernando Zarone; Maria Irene Di Mauro; Pietro Ausiello; Gennaro Ruggiero; Roberto Sorrentino
Journal:  BMC Oral Health       Date:  2019-07-04       Impact factor: 2.757

9.  The marginal discrepancy of lithium disilicate onlays: Computer-aided design versus press.

Authors:  Leneena Gudugunta; Praffulla Mynampati; Matada Basavarajaiah Jeevan; Sathiyavathi Mahendra Kumar; Anitha Akkaloori; Sai Krishna Tejavath
Journal:  J Conserv Dent       Date:  2019 Jul-Aug

10.  Endocrown with Leucite-Reinforced Ceramic: Case of Restoration of Endodontically Treated Teeth.

Authors:  Leonardo Fernandes da Cunha; José Mondelli; Caroline Moreira Auersvald; Carla Castiglia Gonzaga; Rafael Francisco Lia Mondelli; Gisele Maria Correr; Adilson Yoshio Furuse
Journal:  Case Rep Dent       Date:  2015-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.