Effect of water storage time and composite cement thickness on fatigue of a glass-ceramic trilayer system.

Nelson R F A Silva1, Grace M de Souza, Paulo G Coelho, Christian F J Stappert, Elizabeth A Clark, Elizabeth D Rekow, Van P Thompson.   

Abstract

AIM: Static Hertzian contact tests of monolayer glass-ceramics in trilayer configurations (glass-ceramic/cement/composite) have shown that thick cement layers lower strength. This study sought to test the hypothesis that thick resin cement layers lower mouth motion fatigue reliability for flat glass-ceramic/cement/composite trilayer systems and that aging in water reduces reliability.
METHODS: Dicor plates (n > or = 12 per group) (10 x 10 x 0.8 mm(3)) were aluminum-oxide abraded (50 microm), etched (60 s), silanized, and bonded (Rely X ARC) to water aged (30 days) Z100 resin blocks (10 x 10 x 4 mm(3)). Four groups were prepared: (1) thick cement layer (>100 microm) stored in water for 24-48 h, (2) thick cement layer stored for 60 days, (3) thin cement layer (< or =100 microm) stored for 24-48 h, and (4) thin cement layer stored for 60 days. The layered structures were fatigued (2 Hz) utilizing mouth motion loading with a step-stress acceleration method. A master Weibull distribution was calculated and reliability determined (with 90% confidence intervals) at a given number of cycles and load.
RESULTS: The aged group (60 d) with thick cement layer had statistically lower reliability for 20,000 cycles at 150 N peak load (0.11) compared with both nonaged groups (24-48 h) (thin layer = 0.90 and thick layer = 0.82) and aged group with thin cement layer (0.89).
CONCLUSION: Trilayer specimens with thick cement layers exhibited significantly lower reliability under fatigue testing only when stored for 60 days in water. The hypothesis was accepted. These results suggest that diffusion of water into the resin cement and also to the glass-ceramic interface is delayed in the thick cement specimens at 24-48 h. .

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17455281     DOI: 10.1002/jbm.b.30851

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  11 in total

1.  Step-stress analysis for predicting dental ceramic reliability.

Authors:  Márcia Borba; Paulo F Cesar; Jason A Griggs; Alvaro Della Bona
Journal:  Dent Mater       Date:  2013-07-02       Impact factor: 5.304

2.  Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques.

Authors:  Marta Baldassarri; Yu Zhang; Van P Thompson; Elizabeth D Rekow; Christian F J Stappert
Journal:  J Dent       Date:  2011-04-28       Impact factor: 4.379

3.  Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses.

Authors:  Christian F J Stappert; Marta Baldassarri; Yu Zhang; Felix Hänssler; Elizabeth D Rekow
Journal:  Clin Oral Implants Res       Date:  2011-09-05       Impact factor: 5.977

4.  Reliability evaluation of alumina-blasted/acid-etched versus laser-sintered dental implants.

Authors:  Erika O Almeida; Amilcar C Freitas Júnior; Estevam A Bonfante; Nelson R F A Silva; Paulo G Coelho
Journal:  Lasers Med Sci       Date:  2012-07-28       Impact factor: 3.161

5.  Damage maps for layered ceramics under simulated mastication.

Authors:  J-H Kim; J-W Kim; S-W Myoung; M Pines; Y Zhang
Journal:  J Dent Res       Date:  2008-07       Impact factor: 6.116

6.  On the interfacial fracture resistance of resin-bonded zirconia and glass-infiltrated graded zirconia.

Authors:  Herzl Chai; Marina Kaizer; Asima Chughtai; Hui Tong; Carina Tanaka; Yu Zhang
Journal:  Dent Mater       Date:  2015-09-11       Impact factor: 5.304

7.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

8.  The marginal and internal discrepancy of zirconia coping milled by two computer-aided design-computer-aided manufacturing systems.

Authors:  Somchai Urapepon
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

9.  Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.

Authors:  M Vojdani; K Torabi; E Farjood; Aar Khaledi
Journal:  J Dent (Shiraz)       Date:  2013-09

10.  Dentin to dentin adhesion using combinations of resin cements and adhesives from different manufacturers - a novel approach.

Authors:  Elke Seitz; Carl Hjortsjö; Jon E Dahl; Erik Saxegaard
Journal:  Biomater Investig Dent       Date:  2020-07-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.