Literature DB >> 11203858

Leucite-reinforced glass ceramic inlays after six years: wear of luting composites.

N Krämer1, R Frankenberger.   

Abstract

Wear of luting composites is still an unsolved problem with adhesive inlays. However, only limited clinical research has been conducted regarding this phenomenon. This study evaluated the substance loss within the luting gap over a six-year period in vivo. In the course of a controlled prospective clinical study, 16 patients received 39 Class-II IPS Empress inlays. Variolink Low (Vivadent; n = 18) was used as conventional low-viscosity luting composite, the hybrid-type restorative resin composite Tetric (n = 21; Vivadent) was applied according to the ultrasonic insertion technique. The restorations were clinically assessed after 6, 12, 24, 36, 48 and 72 months and replicas were made. The contact-free occlusal areas of the replicas were scanned by use of a computer-controlled profilometer (Perthen S3P), the analysis of the data was computed using a newly developed software (Xpert for Windows 95) and statistically analyzed with non-parametric tests. After six months all restorations exhibited marginal ditching. The percentage of detectable luting gap abrasion increased between each recall appointment (32% after six months, 48% after 12 months, 46% after 24 months, 55% after 36 months, 59% after 48 months and 65% after 72 months). Except for the 48-months results, no significant difference between the materials used for luting was evident (p > 0.05). Between the width and the depth of the luting space a linear regression was computed. The quantitative evaluation clearly demonstrated that hopes of relevantly reduced wear of luting composites were not confirmed when using the higher filled luting material.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203858

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  7 in total

1.  Effect of proximal box elevation with resin composite on marginal quality of ceramic inlays in vitro.

Authors:  Roland Frankenberger; Julia Hehn; Jan Hajtó; Norbert Krämer; Michael Naumann; Andreas Koch; Matthias J Roggendorf
Journal:  Clin Oral Investig       Date:  2012-02-23       Impact factor: 3.573

2.  Statistical failure analysis of adhesive resin cement bonded dental ceramics.

Authors:  Yaou Wang; Noriko Katsube; Robert R Seghi; Stanislav I Rokhlin
Journal:  Eng Fract Mech       Date:  2007-08       Impact factor: 4.406

3.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573

4.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

5.  Indirect composite restorations luted with two different procedures: A ten years follow up clinical trial.

Authors:  Nicola Barabanti; Alessandro Preti; Michele Vano; Giacomo Derchi; Francesco Mangani; Antonio Cerutti
Journal:  J Clin Exp Dent       Date:  2015-02-01

6.  Efficacy of composite versus ceramic inlays and onlays: study protocol for the CECOIA randomized controlled trial.

Authors:  Hélène Fron Chabouis; Caroline Prot; Cyrille Fonteneau; Karim Nasr; Olivier Chabreron; Stéphane Cazier; Christian Moussally; Alexandre Gaucher; Inès Khabthani Ben Jaballah; Renaud Boyer; Jean-François Leforestier; Aurore Caumont-Prim; Florence Chemla; Louis Maman; Cathy Nabet; Jean-Pierre Attal
Journal:  Trials       Date:  2013-09-03       Impact factor: 2.279

7.  Prospective clinical evaluation of 765 partial glass-ceramic posterior restorations luted using photo-polymerized resin composite in conjunction with immediate dentin sealing.

Authors:  Carline R G Van den Breemer; Gerrit J Buijs; Marco S Cune; Mutlu Özcan; Wouter Kerdijk; Stephan Van der Made; Marco M M Gresnigt
Journal:  Clin Oral Investig       Date:  2020-08-12       Impact factor: 3.573

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.