Literature DB >> 10377606

IPS Empress inlays and onlays after four years--a clinical study.

N Krämer1, R Frankenberger, M Pelka, A Petschelt.   

Abstract

OBJECTIVE: Ceramic inlays are used as esthetic alternatives to amalgam and other metallic materials for the restoration of badly damaged teeth. However, only limited clinical data are available regarding adhesive inlays and onlays with proximal margins located in dentine. In a prospective, controlled clinical study, the performance of IPS Empress inlays and onlays with cuspal replacements and margins below the amelocemental junction was examined.
MATERIALS AND METHODS: Ninety-six IPS Empress fillings were placed in 34 patients by six clinicians. The restorations were luted with four different composite systems. The dentin bonding system Syntac Classic was used in addition to the acid-etch-technique. At baseline and after 6 months, one, two and four years after placement the restorations were assessed by two calibrated investigators using modified USPHS codes and criteria. A representative sample of the restorations was investigated by scanning electron microscopy to evaluate wear.
RESULTS: Seven of the 96 restorations investigated had to be replaced (failure rate 7%; Kaplan-Meier). Four inlays had suffered cohesive bulk fractures and three teeth required endodontic treatment. After four years in clinical service, significant deterioration (Friedman 2-way Anova; p < 0.05) was found to have occurred in the marginal adaptation of the remaining restorations. Seventy-nine percent of the surviving restorations exhibited marginal deficiencies, independent of the luting composite. Neither the absence of enamel margins, nor cuspal replacement significantly affected the adhesion or marginal quality of the restorations.
CONCLUSION: After four years, extensive IPS Empress inlays and onlays bonded with the dentin bonding system Syntac Classic were found to have a 7% failure rate with 79% of the remaining restorations having marginal deficiencies.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10377606     DOI: 10.1016/s0300-5712(98)00059-1

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  15 in total

Review 1.  Systematic review of ceramic inlays.

Authors:  M Hayashi; N H F Wilson; C A Yeung; H V Worthington
Journal:  Clin Oral Investig       Date:  2002-12-21       Impact factor: 3.573

2.  Seven-year clinical performance of CEREC-2 all-ceramic CAD/CAM restorations placed within deeply destroyed teeth.

Authors:  Matthias J Roggendorf; Bianka Kunzi; Johannes Ebert; Hubert C Roggendorf; Roland Frankenberger; Sven M Reich
Journal:  Clin Oral Investig       Date:  2011-12-07       Impact factor: 3.573

3.  Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays.

Authors:  Marleen Peumans; M Voet; J De Munck; K Van Landuyt; A Van Ende; B Van Meerbeek
Journal:  Clin Oral Investig       Date:  2012-06-17       Impact factor: 3.573

4.  Analysis of marginal adaptation and sealing to enamel and dentin of four self-adhesive resin cements.

Authors:  Carina Maria Aschenbrenner; Reinhold Lang; Gerhard Handel; Michael Behr
Journal:  Clin Oral Investig       Date:  2011-02-16       Impact factor: 3.573

5.  Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement.

Authors:  Marianne Federlin; Karl-Anton Hiller; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2014-01-10       Impact factor: 3.573

6.  Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years.

Authors:  Frederike Schenke; Marianne Federlin; Karl-Anton Hiller; Daniel Moder; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2011-03-23       Impact factor: 3.573

7.  Two-year clinical performance of cast gold vs ceramic partial crowns.

Authors:  Marianne Federlin; Tobias Männer; Karl-Anton Hiller; Sebastian Schmidt; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2006-04-14       Impact factor: 3.573

8.  Clinical effectiveness of restorative materials for the restoration of carious primary teeth without pulp therapy: a systematic review.

Authors:  S Amend; C Boutsiouki; K Bekes; D Kloukos; N N Lygidakis; R Frankenberger; N Krämer
Journal:  Eur Arch Paediatr Dent       Date:  2022-07-12

9.  Long-term clinical performance and longevity of gold alloy vs ceramic partial crowns.

Authors:  J Wagner; K-A Hiller; G Schmalz
Journal:  Clin Oral Investig       Date:  2003-05-13       Impact factor: 3.573

10.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379