Literature DB >> 11105006

Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays.

H Denissen1, A Dozić, J van der Zel, M van Waas.   

Abstract

STATEMENT OF PROBLEM: Onlay preparations are very complex surfaces for computer surface digitization, CAD, and CAM of all-ceramic onlay cores.
PURPOSE: This study tested the hypothesis that onlays can be fabricated with CICERO, CEREC, and Procera core technologies.
MATERIAL AND METHODS: Fifteen mandibular and 10 maxillary molars were prepared for onlays in 17 patients (11 women and 6 men). The onlay design was experimental. Molars were prepared with deep gingival chamfers in the proximal boxes and around the functional cusps. The nonfunctional cusps were prepared with broad bevels. Eight stone dies of preparations were measured with a laser beam (CICERO), 10 dies with a light beam (CEREC), and 7 dies with a contact probe (Procera). Two onlay cores were produced for the same stone die. One core was used to analyze fit on the stone die, and the other core was porcelain veneered for optimizing anatomy, esthetics, and fit of the onlay and cemented. The fit of the onlay core on the stone die and the cement width on a stone cast were measured by a microscopic digital imaging system. The onlays were evaluated for function every 6 months for 2 years.
RESULTS: Measurements of the margins by the CICERO system were (1) precise (error <4%) and (2) accurate with an SD of less than 9 microm. The proposed onlay preparation design met the requirement that all points of the surface be visible from a single point of view for optical 3-dimensional mapping by the CEREC system. For the surface measurements by the Procera contact probe, the orientation of the sapphire tip toward the preparation surface was critical, and it was necessary to apply wax to smooth internal edges. The marginal gaps of the CICERO, CEREC, and Procera cores on the stone dies were 74 microm (SD 15), 85 microm (SD 40), and 68 microm (SD 53), respectively. The cement width was 81 microm (SD 64). No fractures occurred.
CONCLUSION: Marginal gaps for the onlay cores were no more than 85 microm. The cement width of the semicomputer-produced onlays of 81 microm was a favorable measurement value for a clinically acceptable, strong all-ceramic onlay. However, this value as well as anatomy and esthetics of the onlay depended on the craftsmanship of the porcelain veneering by the dental technician.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11105006     DOI: 10.1067/mpr.2000.110258

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Mechanical interactions of cuspal-coverage designs and cement thickness in a cusp-replacing ceramic premolar restoration: a finite element study.

Authors:  Yen-Hsiang Chang; Wen-Hsueng Lin; Wen-Chieh Kuo; Chia-Yu Chang; Chun-Li Lin
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

2.  Marginal adaptation of ceramic and composite inlays in minimally invasive mod cavities.

Authors:  M Zaruba; R Kasper; R Kazama; F J Wegehaupt; A Ender; T Attin; A Mehl
Journal:  Clin Oral Investig       Date:  2013-05-01       Impact factor: 3.573

3.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

4.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

5.  A comparison of marginal fit of glass infiltrated alumina copings fabricated using two different techniques and the effect of firing cycles over them.

Authors:  Hirasankar Bhowmik; Rambhao Parkhedkar
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

6.  Effect of Different Wax Pattern Manufacturing Techniques on the Marginal Fit of Lithium Disilicate Crowns.

Authors:  Huda Ahmed Alshehri; Sara Mohammed Altaweel; Raghdah Alshaibani; Esraa Ahmed Alahmari; Hanan Nejer Alotaibi; Afnan Fouzan Alfouzan; Nawaf Labban
Journal:  Materials (Basel)       Date:  2022-07-07       Impact factor: 3.748

7.  Clinical gap changes after porcelain firing cycles of zirconia fixed dentures.

Authors:  Bugurman Burcu Bugurman; Sebnem Begum Turker
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

8.  Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing.

Authors:  Yen-Hsiang Chang; Jin-Jie Yu; Chun-Li Lin
Journal:  Biomed Eng Online       Date:  2014-12-13       Impact factor: 2.819

9.  Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study.

Authors:  G Joós-Kovács; B Vecsei; Sz Körmendi; V A Gyarmathy; J Borbély; P Hermann
Journal:  BMC Oral Health       Date:  2019-12-12       Impact factor: 2.757

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.