Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Gengsheng L Zeng1.   

Abstract

Iterative maximum-likelihood expectation maximization and ordered-subset expectation maximization algorithms are excellent for image reconstruction and usually provide better images than filtered backprojection (FBP). Recently, an FBP algorithm able to incorporate noise weighting during reconstruction was developed. This paper compares the performance of the noise-weighted FBP algorithm and the iterative maximum-likelihood expectation maximization algorithm with Poisson noise-corrupted emission data generated by computer simulations and a SPECT experimental study. The results show comparable performance for these 2 algorithms.

Entities:  

Keywords:  ML-EM algorithm; Poisson noise; filtered backprojection algorithm; image reconstruction

Mesh:

Year:  2013        PMID: 24159012      PMCID: PMC4243832          DOI: 10.2967/jnmt.113.127399

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  15 in total

1.  Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study.

Authors:  K Oda; H Toyama; K Uemura; Y Ikoma; Y Kimura; M Senda
Journal:  Ann Nucl Med       Date:  2001-10       Impact factor: 2.668

2.  A filtered backprojection MAP algorithm with nonuniform sampling and noise modeling.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

4.  Multiscale penalized weighted least-squares sinogram restoration for low-dose x-ray computed tomography.

Authors:  Jing Wang; Hongbing Lu; Junhai Wen; Zhengrong Liang
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

5.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

6.  Performance evaluation of filtered backprojection reconstruction and iterative reconstruction methods for PET images.

Authors:  C X Wang; W E Snyder; G Bilbro; P Santago
Journal:  Comput Biol Med       Date:  1998-01       Impact factor: 4.589

7.  A filtered backprojection algorithm with ray-by-ray noise weighting.

Authors:  Gengsheng L Zeng; Alex Zamyatin
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

8.  Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease.

Authors:  E M Prvulovich; A H Lonn; J B Bomanji; P H Jarritt; P J Ell
Journal:  Eur J Nucl Med       Date:  1997-03

9.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

Authors:  X L Xu; J S Liow; S C Strother
Journal:  Med Phys       Date:  1993 Nov-Dec       Impact factor: 4.071

10.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

View more
  5 in total

1.  Noise-weighted spatial domain FBP algorithm.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

2.  Noise-Weighted FBP Algorithm for Uniformly Attenuated SPECT Projections.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2016-06-23       Impact factor: 1.679

3.  Image Noise Covariance Can be Adjusted by a Noise Weighted Filtered Backprojection Algorithm.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-02-18

4.  Comparison of FBP and Iterative Algorithms with Non-Uniform Angular Sampling.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02       Impact factor: 1.679

5.  Model Based Filtered Backprojection Algorithm: A Tutorial.

Authors:  Gengsheng L Zeng
Journal:  Biomed Eng Lett       Date:  2014-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.