Literature DB >> 9644571

Performance evaluation of filtered backprojection reconstruction and iterative reconstruction methods for PET images.

C X Wang1, W E Snyder, G Bilbro, P Santago.   

Abstract

The filtered backprojection (FBP) algorithm and statistical model based iterative algorithms such as the maximum likelihood (ML) reconstruction or the maximum a posteriori (MAP) reconstruction are the two major classes of tomographic reconstruction methods. The FBP method is widely used in clinical setting while iterative methods have attracted research interests in the past decade. In this paper we studied the performance of the FBP, the ML and the MAP methods using simulated projection data. The experiment showed that the MAP algorithm generated superior image quality in terms of the bias, the variance, and the average mean squared error (MSE) measures.

Entities:  

Mesh:

Year:  1998        PMID: 9644571     DOI: 10.1016/s0010-4825(97)00031-0

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  11 in total

1.  A filtered backprojection MAP algorithm with nonuniform sampling and noise modeling.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  A filtered backprojection algorithm with characteristics of the iterative landweber algorithm.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Authors:  Gengsheng L Zeng
Journal:  J Nucl Med Technol       Date:  2013-10-24

4.  Evaluation of image reconstruction algorithms encompassing Time-Of-Flight and Point Spread Function modelling for quantitative cardiac PET: phantom studies.

Authors:  L Presotto; L Gianolli; M C Gilardi; V Bettinardi
Journal:  J Nucl Cardiol       Date:  2014-11-04       Impact factor: 5.952

Review 5.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

6.  Filtered Backprojection Algorithm Can Outperform Iterative Maximum Likelihood Expectation-Maximization Algorithm.

Authors:  Gengsheng L Zeng
Journal:  Int J Imaging Syst Technol       Date:  2012-05-12       Impact factor: 2.000

7.  Effect of reconstruction algorithms on myocardial blood flow measurement with 13N-ammonia PET.

Authors:  Grace P Chen; Kelley R Branch; Adam M Alessio; Pam Pham; Ramin Tabibiazar; Paul Kinahan; James H Caldwell
Journal:  J Nucl Med       Date:  2007-07-13       Impact factor: 10.057

8.  Evaluation of Origin Ensemble algorithm for image reconstruction for pixelated solid-state detectors with large number of channels.

Authors:  M Kolstein; G De Lorenzo; E Mikhaylova; M Chmeissani; G Ariño; Y Calderón; I Ozsahin; D Uzun
Journal:  J Instrum       Date:  2013-04-29       Impact factor: 1.415

9.  Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements.

Authors:  Alexander Wong; Chenyi Liu; Xiao Yu Wang; Paul Fieguth; Hongxia Bie
Journal:  BMC Med Imaging       Date:  2015-03-18       Impact factor: 1.930

10.  Optimization, evaluation, and comparison of standard algorithms for image reconstruction with the VIP-PET.

Authors:  E Mikhaylova; M Kolstein; G De Lorenzo; M Chmeissani
Journal:  J Instrum       Date:  2014-07       Impact factor: 1.415

View more