Noise-Weighted FBP Algorithm for Uniformly Attenuated SPECT Projections.

Gengsheng L Zeng.   

Abstract

Noise-weighted FBP (filtered backprojection) algorithm and Bayesian FBP algorithm were developed recently for un-attenuated Radon transform, which have applications in x-ray CT (computed tomography). This paper extends the noise-weighted FBP algorithm to the case of uniformly attenuated Radon transform, and this extended FBP algorithm can be applied in uniformly attenuated SPECT (single photon emission computed tomography). Computer simulations and experimental data demonstrate that the proposed FBP algorithm has similar noise control capability as the iterative ML-EM (maximum likelihood expectation maximization) algorithm. In practice, the attenuator is rarely uniform. A stable FBP algorithm must be developed for non-uniform attenuators before the FBP algorithm can be applied in clinics when attenuation correction is required.

Entities:  

Keywords:  Attenuated Radon transform; Poisson noise; SPECT; analytical algorithm; exponential Radon transform; filtered backprojection algorithm

Year:  2016        PMID: 27840452      PMCID: PMC5102335          DOI: 10.1109/TNS.2016.2564924

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  16 in total

1.  A filtered backprojection MAP algorithm with nonuniform sampling and noise modeling.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  A filtered backprojection algorithm with characteristics of the iterative landweber algorithm.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Exact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.

Authors:  Qiulin Tang; Gengsheng L Zeng; Jiansheng Wu; Grant T Gullberg
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

4.  Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT.

Authors:  Qiulin Tang; Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2005-06-22       Impact factor: 3.609

5.  An alternative proof of Bukhgeim and Kazantsev's inversion formula for attenuated fan-beam projections.

Authors:  Qiu Huang; Gengsheng L Zeng; Jiansheng Wu
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

6.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

7.  Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Authors:  Gengsheng L Zeng
Journal:  J Nucl Med Technol       Date:  2013-10-24

8.  Revisit of the Ramp Filter.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02       Impact factor: 1.679

9.  Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuation.

Authors:  T Inouye; K Kose; A Hasegawa
Journal:  Phys Med Biol       Date:  1989-03       Impact factor: 3.609

10.  Computerized transverse axial scanning (tomography). 1. Description of system.

Authors:  G N Hounsfield
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

View more
  1 in total

1.  Filtered backprojection implementation of the immediately-after-backprojection filtering.

Authors:  Gengsheng L Zeng
Journal:  Biomed Phys Eng Express       Date:  2018-06-13
  1 in total