Literature DB >> 15669456

Reliability of preoperative templating in total knee arthroplasty.

Nadim Aslam1, Steven Lo, Kugan Nagarajah, Chandra Pasapula, Mo Akmal.   

Abstract

The purpose of this study was to determine the reliability of preoperative templating in primary total knee arthroplasty and the influence of the seniority of the surgeon on templating. A retrospective study of 25 randomly selected total knee replacements was undertaken, with templating of preoperative radiographs by four surgical staff members. These included a consultant, a specialist registrar and two senior house officers. Reliability for an exact match between template size and implant actually used was 49% for the femoral component and 67% for the tibial component. The statistical agreement between templated size and actual implant size was classed as only fair to moderate. There was no statistical difference in templating reliability between junior and senior surgical staff. These results indicate that the current system of templating for total knee arthoplasties is prone to error and can only be used as an approximate guide.

Mesh:

Year:  2004        PMID: 15669456

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  6 in total

1.  Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty.

Authors:  Hiroyuki Nakahara; Shuichi Matsuda; Ken Okazaki; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  Clin Orthop Relat Res       Date:  2012-05-19       Impact factor: 4.176

2.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

3.  The accuracy and reliability of pre-operative templating in revision total knee arthroplasty. A comparison of analogue and digital methods.

Authors:  Neil Prakash Morgan Jain; Paul Michael Guyver; Michael James Hayden McCarthy; James Press; Jonathan Keenan
Journal:  J Orthop       Date:  2014-07-17

4.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

5.  Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

Authors:  A J Kievit; J G G Dobbe; G J Streekstra; L Blankevoort; M U Schafroth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-09-25       Impact factor: 4.342

6.  Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement.

Authors:  Daniel Hernández-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Ivan Perez-Coto; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  J Orthop Translat       Date:  2018-11-22       Impact factor: 5.191

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.