| Literature DB >> 24146917 |
Kazutaka Kamiya1, Kimiya Shimizu, Akihito Igarashi, Hidenaga Kobashi.
Abstract
PURPOSE: To assess the time course of optical quality and intraocular scattering in relation to visual acuity after femtosecond lenticule extraction (FLEx) for the correction of myopia.Entities:
Mesh:
Year: 2013 PMID: 24146917 PMCID: PMC3797688 DOI: 10.1371/journal.pone.0076738
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Preoperative demographics of the study population.
| Demographic Data | |
| Age (years) | 31.0±5.5 years (range, 20 to 41 years) |
| Gender (% female) | 72% |
| LogMAR UCVA | 1.13±0.24 (range, 0.30 to 1.40) |
| LogMAR CDVA | −0.23±0.06 (range, −0.30 to −0.18) |
| Manifest spherical equivalent (D) | −4.38±1.53 D (range, −1.50 to −7.50 D) |
| Manifest cylinder (D) | −0.62±0.66 D (range, 0.00 to −2.75 D) |
| Mean keratometric reading (D) | 43.4±1.1 D (range, 41.5 to 46.0 D) |
| Pupil diameter (mm) | 5.8±0.8 mm (range, 4.1 to 7.2 mm) |
LogMAR = logarithm of the minimal angle of resolution, UDVA = uncorrected distance visual acuity, CDVA = corrected distance visual acuity, D = diopters.
Figure 1The representative point spread function images of eyes undergoing femtosecond lenticule extraction preoperatively, and 1 week and 1, 3 and 6 months postoperatively.
Figure 2The representative modulation transfer function curves of eyes undergoing femtosecond lenticule extraction preoperatively, and 1 week and 1, 3 and 6 months postoperatively.
Time course of the detailed optical parameters of the eye.
| Preoperative | Postoperative (Dunnett test) | ||||||||
| 1 week | P value | 1 month | P value | 3 months | P value | 6 months | P value | ||
| MTF cutoff frequency (cpd) | 32.92±12.48 | 19.68±9.17 | <0.001 | 21.22±10.35 | <0.001 | 25.98±10.48 | 0.02 | 27.42±9.07 | 0.08 |
| Strehl ratio | 0.19±0.07 | 0.13±0.05 | <0.001 | 0.13±0.05 | <0.001 | 0.16±0.05 | 0.03 | 0.16±0.04 | 0.02 |
| OSI | 0.90±0.52 | 2.38±1.77 | <0.001 | 2.07±1.34 | <0.001 | 1.44±0.83 | 0.22 | 1.26±0.68 | 0.61 |
| OV 100% | 1.10±0.41 | 0.66±0.31 | <0.001 | 0.71±0.34 | <0.001 | 0.87±0.35 | 0.02 | 0.92±0.29 | 0.11 |
| OV 20% | 0.80±0.34 | 0.49±0.22 | <0.001 | 0.53±0.27 | <0.001 | 0.62±0.25 | 0.02 | 0.66±0.23 | 0.03 |
| OV 9% | 0.48±0.21 | 0.32±0.15 | <0.001 | 0.33±0.18 | <0.001 | 0.39±0.15 | 0.07 | 0.39±0.13 | 0.02 |
| LogMAR CDVA | 0.23±0.06 | −0.16±0.11 | <0.001 | −0.19±0.10 | 0.12 | −0.20±0.08 | 0.22 | −0.20±0.08 | 0.47 |
cpd = cycles/degree, OSI = objective scattering index, logMAR = logarithm of the minimal angle of resolution, OV = OQAS value, CDVA = corrected distance visual acuity.