Literature DB >> 22661546

Clinical evaluation of optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation.

Kazutaka Kamiya1, Kimiya Shimizu, Akihito Igarashi, Hidenaga Kobashi, Rie Ishii, Nobuyuki Sato.   

Abstract

PURPOSE: We assessed the optical quality and intraocular scattering after posterior chamber phakic intraocular lens implantation.
METHODS: We examined prospectively 38 eyes of 19 consecutive patients undergoing implantable contact lens (ICL) implantation (mean age ± SD 36.3 ± 5.7 years), and 38 age-matched normal eyes of 19 healthy volunteers (mean age 36.4 ± 4.9 years). We assessed quantitatively the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and the Optical Quality Analysis System (OQAS) values (OVs). We compared these variables in eyes undergoing ICL implantation to those in healthy eyes.
RESULTS: The mean MTF cutoff frequency, Strehl ratio, OSI, OV 100%, OV 20%, and OV 9% were 28.69 ± 8.59 cycles/degree, 0.17 ± 0.04, 1.06 ± 0.48, 0.96 ± 0.29, 0.83 ± 0.31, and 0.83 ± 0.32, respectively, 3 months after ICL implantation. We found no significant differences in the MTF cutoff frequency (Mann Whitney U test, P = 0.31), Strehl ratio (P = 0.46), OSI (P = 0.30), or OVs at contrasts of 100% (P = 0.51), 20% (P = 0.46), and 9% (P = 0.36), between the ICL and control groups.
CONCLUSIONS: The optical quality parameters, such as the MTF cutoff frequency, Strehl ratio, OSI, or OVs in the ICL group, were not significantly different from those in the control group, suggesting that the optical quality and intraocular scattering of eyes undergoing ICL implantation essentially was equivalent to those of healthy eyes.

Entities:  

Mesh:

Year:  2012        PMID: 22661546     DOI: 10.1167/iovs.12-9650

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  16 in total

1.  Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System.

Authors:  Yan Chen; Xue Wang; Chuan-Di Zhou; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

2.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

3.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

4.  Agreement between subjective and predicted high and low contrast visual acuities with a double-pass system.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David P Piñero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-10-31       Impact factor: 3.117

5.  Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation using the double-pass instrument.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Aya Saito; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

6.  Clinical evaluation of accommodation and ocular surface stability relevant to visual asthenopia with 3D displays.

Authors:  Sung Wook Wee; Nam Ju Moon
Journal:  BMC Ophthalmol       Date:  2014-03-11       Impact factor: 2.209

7.  Implantable collamer lens V4b and V4c for correction of high myopia.

Authors:  Vipul Bhandari; Smitha Karandikar; Jagdeesh K Reddy; Kirti Relekar
Journal:  J Curr Ophthalmol       Date:  2016-02-09

8.  Repeatability, Reproducibility, and Comparability of Subjective and Objective Measurements of Intraocular Forward Scattering in Healthy Subjects.

Authors:  Ayaka Iijima; Kimiya Shimizu; Hidenaga Kobashi; Aya Saito; Kazutaka Kamiya
Journal:  Biomed Res Int       Date:  2015-06-14       Impact factor: 3.411

9.  Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.

Authors:  Mi Tian; Huamao Miao; Yang Shen; Jian Gao; Xiaofen Mo; Xingtao Zhou
Journal:  PLoS One       Date:  2015-11-04       Impact factor: 3.240

10.  Time course of optical quality and intraocular scattering after refractive lenticule extraction.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Hidenaga Kobashi
Journal:  PLoS One       Date:  2013-10-16       Impact factor: 3.240