First efficacy and safety study of femtosecond lenticule extraction for the correction of myopia: six-month results.

Walter Sekundo1, Kathleen Kunert, Christoph Russmann, Annika Gille, Wilfried Bissmann, Gregor Stobrawa, Markus Sticker, Mark Bischoff, Marcus Blum.   

Abstract

PURPOSE: To prospectively study the feasibility of femtosecond lenticule extraction (FLE), a new method of refractive correction.
SETTING: Department of Ophthalmology, Philipps University of Marburg and Helios Clinic, Erfurt, Germany.
METHODS: A flap and a lenticule of intrastromal corneal tissue were simultaneously cut with a VisuMax femtosecond laser system. Next, the lenticule was manually removed and the flap repositioned. The target refraction in all cases was -0.75 diopter (D).
RESULTS: All 10 myopic eyes in the initial treatment group completed the final 6-month follow-up. The mean patient age was 39 years. The mean spherical equivalent (SE) was -4.73 +/- 1.48 (SD) preoperatively and -0.33 +/- 0.61 D 6 months postoperatively. Ninety percent of eyes were within +/-1.00 D and 40% were within +/-0.50 D of the intended correction. No eye lost 2 or more Snellen lines. Corneal topography showed large, prolate optical zones. Aberrometry showed no significant induction of higher-order aberrations. On a standardized questionnaire, all patients said they were very satisfied with the results.
CONCLUSIONS: Preliminary results indicate that FLEx [corrected] is a promising new corneal refractive procedure to correct myopia.

Entities:  

Mesh:

Year:  2008        PMID: 18721712     DOI: 10.1016/j.jcrs.2008.05.033

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  76 in total

1.  Relationship between femtosecond laser parameters and quality of the corneal stromal bed surface.

Authors:  Zhen-Yong Zhang; Matthew R Hoffman
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-12-02       Impact factor: 3.117

2.  Simulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses.

Authors:  Hui Sun; Nora Hosszufalusi; Eric R Mikula; Tibor Juhasz
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

3.  Femtosecond lenticule extraction (ReLEx) for correction of hyperopia - first results.

Authors:  Marcus Blum; Kathleen S Kunert; Urs Voßmerbäumer; Walter Sekundo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-14       Impact factor: 3.117

4.  [Femtosecond lenticule extraction (FLEx)].

Authors:  M Blum; W Sekundo
Journal:  Ophthalmologe       Date:  2010-10       Impact factor: 1.059

5.  Finite element model of the temperature increase in excised porcine cadaver iris during direct illumination by femtosecond laser pulses.

Authors:  Hui Sun; Ronald M Kurtz; Tibor Juhasz
Journal:  J Biomed Opt       Date:  2012-07       Impact factor: 3.170

6.  Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: finite-element analysis.

Authors:  Abhijit Sinha Roy; William J Dupps; Cynthia J Roberts
Journal:  J Cataract Refract Surg       Date:  2014-06       Impact factor: 3.351

7.  Short term effects of small incision lenticule extraction surgery on corneal endothelium.

Authors:  Dan-Yang Wang; Man-Li Liu; Yi-Le Chen; Xiao-Ying Zhang; Yang-Tao Xu; Jian-Chao Wang; Chi-Ho To; Jian-Guo Wang; Quan Liu
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

8.  Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters.

Authors:  Kathleen S Kunert; Marcus Blum; Gernot I W Duncker; Rabea Sietmann; Jens Heichel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-01-15       Impact factor: 3.117

Review 9.  Femtosecond laser in refractive and cataract surgeries.

Authors:  Han-Han Liu; Ying Hu; Hong-Ping Cui
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

Review 10.  [Refractive lenticule extraction - The ReLEx/SMILE technique : Video article].

Authors:  M Blum; W Sekundo
Journal:  Ophthalmologe       Date:  2017-09       Impact factor: 1.059

View more