Literature DB >> 3598754

Determination of the point-spread function of human eyes using a hybrid optical-digital method.

J Santamaría, P Artal, J Bescós.   

Abstract

A method for the determination of the bidimensional optical transfer function (OTF) and the point-spread function of human eyes is presented. Aerial short-term images of a point source are directly recorded with a TV camera and fed into a digital image-processing system that allows one to determine and display such functions. The method has been implemented in such a way that recording and computation can be carried out on a routine basis with minimum discomfort for the observer. A detailed description of the method and typical aerial and retinal images of a point source as well as the OTF's results are presented in this paper.

Entities:  

Mesh:

Year:  1987        PMID: 3598754     DOI: 10.1364/josaa.4.001109

Source DB:  PubMed          Journal:  J Opt Soc Am A        ISSN: 0740-3232            Impact factor:   2.129


  18 in total

1.  Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System.

Authors:  Yan Chen; Xue Wang; Chuan-Di Zhou; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2017-06-18       Impact factor: 1.779

2.  Performance of a differential contrast sensitivity method to measure intraocular scattering.

Authors:  Alexandros Pennos; Harilaos Ginis; Augusto Arias; Dimitrios Christaras; Pablo Artal
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

3.  Microbial spectrum and antibiotic sensitivity in infantile dacryocystitis.

Authors:  Huiling Qing; Zhengwei Yang; Menghai Shi; Junge Zhang; Shengtao Sun; Lei Han
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-08       Impact factor: 3.117

4.  Light scattering in intraocular lenses explanted 15 to 40 years after surgery.

Authors:  Jorge L Alio; Augusto Arias; Francesco D'Oria; Francesca Toto; Jorge Alio Del Barrio; Raul Duarte; Pablo Artal
Journal:  Biomed Opt Express       Date:  2021-05-18       Impact factor: 3.732

5.  Optical quality of toric intraocular lens implantation in cataract surgery.

Authors:  Xian-Wen Xiao; Jing Hao; Hong Zhang; Fang Tian
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size.

Authors:  Gareth D Hastings; Jason D Marsack; Larry N Thibos; Raymond A Applegate
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2018-05-01       Impact factor: 2.129

7.  Monocular diplopia due to spherocylindrical refractive errors (an American Ophthalmological Society thesis).

Authors:  Steven M Archer
Journal:  Trans Am Ophthalmol Soc       Date:  2007

8.  Impact of scatter on double-pass image quality and contrast sensitivity measured with a single instrument.

Authors:  Juan M Bueno; Guillermo Pérez; Antonio Benito; Pablo Artal
Journal:  Biomed Opt Express       Date:  2015-11-13       Impact factor: 3.732

9.  Compact optical integration instrument to measure intraocular straylight.

Authors:  Harilaos Ginis; Onurcan Sahin; Alexandros Pennos; Pablo Artal
Journal:  Biomed Opt Express       Date:  2014-08-14       Impact factor: 3.732

10.  An objective scatter index based on double-pass retinal images of a point source to classify cataracts.

Authors:  Pablo Artal; Antonio Benito; Guillermo M Pérez; Encarna Alcón; Alvaro De Casas; Jaume Pujol; José M Marín
Journal:  PLoS One       Date:  2011-02-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.