Literature DB >> 24089922

Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

Yothin Rakvongthai1, Jinsong Ouyang, Bastien Guerin, Quanzheng Li, Nathaniel M Alpert, Georges El Fakhri.   

Abstract

PURPOSE: Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach.
METHODS: Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach.
RESULTS: At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%-29% and 32%-70% for 50 × 10(6) and 10 × 10(6) detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40-50 iterations), while more than 500 iterations were needed for CG.
CONCLUSIONS: The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method.

Entities:  

Mesh:

Year:  2013        PMID: 24089922      PMCID: PMC3779266          DOI: 10.1118/1.4819821

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Spatiotemporal reconstruction of list-mode PET data.

Authors:  Thomas E Nichols; Jinyi Qi; Evren Asma; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2002-04       Impact factor: 10.048

Review 2.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

3.  Noise properties of the EM algorithm: I. Theory.

Authors:  H H Barrett; D W Wilson; B M Tsui
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

Review 4.  PET/CT: challenge for nuclear cardiology.

Authors:  Markus Schwaiger; Sibylle Ziegler; Stephan G Nekolla
Journal:  J Nucl Med       Date:  2005-10       Impact factor: 10.057

5.  Joint estimation of dynamic PET images and temporal basis functions using fully 4D ML-EM.

Authors:  Andrew J Reader; Florent C Sureau; Claude Comtat; Régine Trébossen; Irène Buvat
Journal:  Phys Med Biol       Date:  2006-10-06       Impact factor: 3.609

6.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

Review 8.  Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction.

Authors:  Arman Rahmim; Jing Tang; Habib Zaidi
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

9.  An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2012-08-08       Impact factor: 10.048

10.  Direct 4-D PET list mode parametric reconstruction with a novel EM algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Trans Med Imaging       Date:  2012-08-23       Impact factor: 10.048

View more
  4 in total

1.  Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

Authors:  Mary Germino; Richard E Carson
Journal:  Med Phys       Date:  2017-12-30       Impact factor: 4.071

2.  Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

Authors:  Yoann Petibon; Yothin Rakvongthai; Georges El Fakhri; Jinsong Ouyang
Journal:  Phys Med Biol       Date:  2017-04-05       Impact factor: 3.609

3.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

4.  Effect of Bayesian-penalized likelihood reconstruction on [13N]-NH3 rest perfusion quantification.

Authors:  Jim O' Doherty; Daniel R McGowan; Carla Abreu; Sally Barrington
Journal:  J Nucl Cardiol       Date:  2016-07-19       Impact factor: 5.952

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.