Literature DB >> 12022627

Spatiotemporal reconstruction of list-mode PET data.

Thomas E Nichols1, Jinyi Qi, Evren Asma, Richard M Leahy.   

Abstract

We describe a method for computing a continuous time estimate of tracer density using list-mode positron emission tomography data. The rate function in each voxel is modeled as an inhomogeneous Poisson process whose rate function can be represented using a cubic B-spline basis. The rate functions are estimated by maximizing the likelihood of the arrival times of detected photon pairs over the control vertices of the spline, modified by quadratic spatial and temporal smoothness penalties and a penalty term to enforce nonnegativity. Randoms rate functions are estimated by assuming independence between the spatial and temporal randoms distributions. Similarly, scatter rate functions are estimated by assuming spatiotemporal independence and that the temporal distribution of the scatter is proportional to the temporal distribution of the trues. A quantitative evaluation was performed using simulated data and the method is also demonstrated in a human study using 11C-raclopride.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12022627     DOI: 10.1109/TMI.2002.1000263

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Detectability of perfusion defect in five-dimensional gated-dynamic cardiac SPECT images.

Authors:  Xiaofeng Niu; Yongyi Yang; Michael A King; Miles N Wernick
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Direct 4D List Mode Parametric Reconstruction for PET with a Novel EM Algorithm.

Authors:  Jianhua Yan; Beata Planeta-Wilson; Richard E Carson
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008

3.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

Authors:  Jing Tang; Hiroto Kuwabara; Dean F Wong; Arman Rahmim
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

4.  Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

Authors:  Yothin Rakvongthai; Jinsong Ouyang; Bastien Guerin; Quanzheng Li; Nathaniel M Alpert; Georges El Fakhri
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

5.  Representation of photon limited data in emission tomography using origin ensembles.

Authors:  A Sitek
Journal:  Phys Med Biol       Date:  2008-05-27       Impact factor: 3.609

6.  Patlak image estimation from dual time-point list-mode PET data.

Authors:  Wentao Zhu; Quanzheng Li; Bing Bai; Peter S Conti; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2014-04       Impact factor: 10.048

Review 7.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

8.  A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

Authors:  S Tong; A M Alessio; P E Kinahan; H Liu; P Shi
Journal:  Phys Med Biol       Date:  2011-03-25       Impact factor: 3.609

9.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

10.  Nonlinear spatio-temporal filtering of dynamic PET data using a four-dimensional Gaussian filter and expectation-maximization deconvolution.

Authors:  J M Floberg; J E Holden
Journal:  Phys Med Biol       Date:  2013-02-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.