Literature DB >> 24070085

Safety and feasibility of a novel vascular closure device in neurointerventional procedures.

Ammar Taha1, Ellen K Walsh, Kathryn A Wright, Iftikhar Ahmed, Nucharin Supakul, Eric E Awwad, Juan G Tejada.   

Abstract

This retrospective study evaluated the safety and feasibility of a new arterial femoral access closure device in neurointerventional procedures. The study includes all consecutive adult patients who underwent femoral arteriotomy closure with the MynxGrip™ closure device after Neurointerventional procedures performed between June and December 2012. All patients had a follow-up color Doppler ultrasound (US) within 48 hours after the procedure, which was independently interpreted by two experienced radiologists to evaluate for access site complications. Device success/failure, sheath size, ambulation time, and periprocedural complications were recorded. Fifty-five closure devices were deployed in 53 patients. There were 23 (43%) males and 30 (57%) females; age ranged from 22 to 84 years (mean: 52.1 years). Thirty of the 55 procedures (55%) were therapeutic and 25 were diagnostic interventions (45%). Sheath sizes used were 5F in 35 procedures (64 %) and 6F in 20 procedures (36%). The right femoral artery was accessed in 51 procedures (93 %) and the left in four procedures (7%). There was only one (1.8 %) minor periprocedural complication (small hematoma). Hemostasis was successful in 51 of the 55 procedures (93 %) with subsequent early ambulation. No device-induced complications associated with serious clinical sequelae were reported. In our small series, the MynxGrip™ femoral access closure device provided a safe and feasible way of closing the femoral artery puncture site after neurointerventional procedures with low minor complication rates and no major complications. Further large prospective randomized trials are necessary to evaluate the efficacy of the device.

Entities:  

Mesh:

Year:  2013        PMID: 24070085      PMCID: PMC3806011          DOI: 10.1177/159101991301900313

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  19 in total

1.  Complications of femoral artery closure devices.

Authors:  D Carey; J R Martin; C A Moore; M C Valentine; T W Nygaard
Journal:  Catheter Cardiovasc Interv       Date:  2001-01       Impact factor: 2.692

Review 2.  Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures: a meta-analysis.

Authors:  Eugenia Nikolsky; Roxana Mehran; Amir Halkin; Eve D Aymong; Gary S Mintz; Zoran Lasic; Manuela Negoita; Martin Fahy; Shoshana Krieger; Issam Moussa; Jeffrey W Moses; Gregg W Stone; Martin B Leon; Stuart J Pocock; George Dangas
Journal:  J Am Coll Cardiol       Date:  2004-09-15       Impact factor: 24.094

3.  Angioseal versus manual compression for haemostasis following peripheral vascular diagnostic and interventional procedures--a randomized controlled trial.

Authors:  S S Upponi; A G Ganeshan; D R Warakaulle; J Phillips-Hughes; P Boardman; R Uberoi
Journal:  Eur J Radiol       Date:  2006-10-30       Impact factor: 3.528

4.  Occurrence of angiographic femoral artery complications after vascular closure with Mynx and AngioSeal.

Authors:  Kyle M Fargen; Gregory J Velat; Matthew F Lawson; Charles A Ritchie; Christopher Firment; Brian L Hoh; Jeffery A Bennett; J Mocco
Journal:  J Neurointerv Surg       Date:  2012-01-21       Impact factor: 5.836

5.  A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.

Authors:  T A Sanborn; H H Gibbs; J A Brinker; W D Knopf; E J Kosinski; G S Roubin
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

6.  Vascular complications after balloon and new device angioplasty.

Authors:  J J Popma; L F Satler; A D Pichard; K M Kent; A Campbell; Y C Chuang; C Clark; A J Merritt; T A Bucher; M B Leon
Journal:  Circulation       Date:  1993-10       Impact factor: 29.690

7.  The safety and efficacy of the Angio-Seal closure device in diagnostic and interventional neuroangiography setting: a single-center experience with 1,443 closures.

Authors:  Serdar Geyik; Kivilcim Yavuz; Ayca Akgoz; Osman Koc; Bora Peynircioglu; Barbaros Cil; Saruhan Cekirge; Isil Saatci
Journal:  Neuroradiology       Date:  2007-06-27       Impact factor: 2.804

Review 8.  Peripheral vascular complications following coronary interventional procedures.

Authors:  T K Nasser; E R Mohler; R L Wilensky; D R Hathaway
Journal:  Clin Cardiol       Date:  1995-11       Impact factor: 2.882

9.  Acute leg ischemia: the dark side of a percutaneous femoral artery closure device.

Authors:  Jan Wille; Jan Albert Vos; Tim T C Overtoom; Maarten J Suttorp; Eric D W M van de Pavoordt; Jean-Paul P M de Vries
Journal:  Ann Vasc Surg       Date:  2006-03-21       Impact factor: 1.466

10.  The use of the Angioseal device for femoral artery closure.

Authors:  Alan Abando; Douglas Hood; Fred Weaver; Steven Katz
Journal:  J Vasc Surg       Date:  2004-08       Impact factor: 4.268

View more
  2 in total

1.  Incidence of delayed angiographic femoral artery complications using the EXOSEAL vascular closure device.

Authors:  Ramesh Grandhi; Xiaoran Zhang; David Panczykowski; Phillip Choi; Christopher T Hunnicutt; Ashutosh P Jadhav; Andrew F Ducruet; Tudor Jovin; Brian Jankowitz
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

2.  A nomogram for predicting the risk of femoral pseudoaneurysm after neurointerventional procedures.

Authors:  Liangliang Yang; Puyuan Zhao; Bin Liu; Yang Gao; Hao Zhou; Qiuping Li; Yingchuan Jiang; Zhigang Yang
Journal:  Ann Transl Med       Date:  2022-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.