Literature DB >> 8227779

A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.

T A Sanborn1, H H Gibbs, J A Brinker, W D Knopf, E J Kosinski, G S Roubin.   

Abstract

OBJECTIVES: A new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty.
BACKGROUND: Peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures.
METHODS: A prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques.
RESULTS: After diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n = 90 patients] vs. 17.6 +/- 9.2 min [n = 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving heparin], 7.6 +/- 11.6 min [n = 85 receiving heparin], 33.6 +/- 24.2 min [n = 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 h vs. 19.2 +/- 17.8 h, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 h, without heparin), as compared with control compression techniques (32.7 +/- 18.8 h, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14).
CONCLUSIONS: A new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications. The role of this technology in reducing complications, length of hospital stay and cost remains to be determined.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8227779     DOI: 10.1016/0735-1097(93)90529-a

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  18 in total

1.  [Hemostatic closure of arterial puncture site using Angio-Seal after diagnostic heart catheterization or coronary intervention].

Authors:  H Eggebrecht; M Haude; D Baumgart; O Oldenburg; J Herrmann; C Bruch; P Hunold; C Neurohr; C von Birgelen; D Welge; M A Katz; R Erbel
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

2.  Final report of the European multi-center registry using the Duett vascular sealing device.

Authors:  S Silber; A J Tofte; T O Kjellevand; E Grube; G Gershony
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

3.  The Duett closure device: concept and experimental results.

Authors:  G Gershony; T Jensen
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

4.  Occlusion of the femoral artery after using the percutaneous suture-mediated closure system perclose.

Authors:  H Kälsch; T Konorza; R Erbel
Journal:  Clin Res Cardiol       Date:  2006-09-08       Impact factor: 5.460

5.  Safety and feasibility of a novel vascular closure device in neurointerventional procedures.

Authors:  Ammar Taha; Ellen K Walsh; Kathryn A Wright; Iftikhar Ahmed; Nucharin Supakul; Eric E Awwad; Juan G Tejada
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

6.  Bleeding complications after contemporary pharmacoinvasive therapy for ST elevation myocardial infarction.

Authors:  Matthew J Gutierrez; Atul Aggarwal; Kristin Gilbert; Burton E Sobel; Harold L Dauerman
Journal:  J Thromb Thrombolysis       Date:  2004-12       Impact factor: 2.300

7.  Development, preclinical evaluation and validation of a novel quick vascular closure device for transluminal, cardiac and radiological arterial catheterization.

Authors:  C Linti; M Doser; H Planck; S Oberhoffner; E Mueller; M Renardy; J Biesinger; B Neumann; K Stang; T O Greiner; C Schlensak; S Krajewski; H P Wendel
Journal:  J Mater Sci Mater Med       Date:  2018-06-11       Impact factor: 3.896

8.  Usefulness of a Nonsuture Closure Device in Patients Undergoing Diagnostic Coronary and Peripheral Angiography.

Authors:  John T Owens; Shaun Bhatty; Robert J Donovan; Andrea Tordini; Peter Danyi; Kalpesh Patel; Jacob A Wegelin; Ion S Jovin
Journal:  Int J Angiol       Date:  2017-10-04

9.  Randomized comparison of effects of suture-based and collagen-based vascular closure devices on post-procedural leg perfusion.

Authors:  H I M Kälsch; H Eggebrecht; S Mayringer; T Konorza; B Sievers; S Sack; R Erbel; K Kroeger
Journal:  Clin Res Cardiol       Date:  2007-09-18       Impact factor: 5.460

10.  Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

Authors:  Ching-Pei Chen; Huang-Kai Huang; Chien-Hsun Hsia; Yung-Ming Chang; Lee-Shin Lin; Cheng-Liang Lee
Journal:  Acta Cardiol Sin       Date:  2013-11       Impact factor: 2.672

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.