Literature DB >> 17071040

Angioseal versus manual compression for haemostasis following peripheral vascular diagnostic and interventional procedures--a randomized controlled trial.

S S Upponi1, A G Ganeshan, D R Warakaulle, J Phillips-Hughes, P Boardman, R Uberoi.   

Abstract

The aim of this study was to compare the angioseal device to manual compression for femoral artery puncture following peripheral vascular procedures, in the context of day case vascular procedures. One hundred patients were prospectively randomised to haemostasis using the angioseal device or manual compression following arterial puncture for peripheral vascular diagnostic or intervention procedures. Data were collected regarding time to haemostasis and complications immediately post-procedure, at 1h, 2h and at 1 week. There were 50 patients in each group. There were no significant differences in demographic variables, or in complication rates immediately, at 1h, 2h and at 1 week (Chi-squared). The only significant difference between the two groups was time to haemostasis. The mean time to haemostasis in the compression group was 10.6 min and 2.0 min in the angioseal group (t-test p<0.0001). In conclusion, no significant differences in complications were found between manual compression and angioseal. However, there was a significant difference in time to haemostasis.

Entities:  

Mesh:

Year:  2006        PMID: 17071040     DOI: 10.1016/j.ejrad.2006.09.007

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  13 in total

1.  Safety and feasibility of a novel vascular closure device in neurointerventional procedures.

Authors:  Ammar Taha; Ellen K Walsh; Kathryn A Wright; Iftikhar Ahmed; Nucharin Supakul; Eric E Awwad; Juan G Tejada
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

Review 2.  [Imaging techniques in the evaluation of primary large vessel vasculitides: part 1: angiography, interventional therapy, and magnetic resonance imaging].

Authors:  M Both; B Nölle; C von Forstner; F Moosig; W L Gross; M Heller
Journal:  Z Rheumatol       Date:  2009-08       Impact factor: 1.372

3.  Angio-Seal™ Evolution™ versus Manual Compression for Common Femoral Artery Puncture in Neurovascular Diagnostic Angiography : A Prospective, Non-Randomized Study.

Authors:  Joonho Chung; Dong Woo Lee; Ok Sim Kwon; Bum-Soo Kim; Yong Sam Shin
Journal:  J Korean Neurosurg Soc       Date:  2011-03-31

4.  Comparison of Angioseal and Manual Compression in Patients Undergoing Transfemoral Coronary and Peripheral Vascular Interventional Procedures.

Authors:  Abdullah M Alshehri; Mohamed Elsharawy
Journal:  Int J Angiol       Date:  2015-06

5.  Use of ultrasound in the insertion of a vascular closure device: a comparative retrospective study with the standard blind technique.

Authors:  Pierleone Lucatelli; Alessandro Cannavale; Carlo Cirelli; Alessandro d'Adamo; Filippo Maria Salvatori; Fabrizio Fanelli
Journal:  Radiol Med       Date:  2014-08-15       Impact factor: 3.469

6.  Guidelines for Bystander First Aid 2016.

Authors:  Jen Heng Pek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

7.  Arterial closure device to achieve hemostasis in children following percutaneous femoral arterial puncture.

Authors:  Somnath J Prabhu; Siddharth A Padia; Karim Valji; Michael F McNeeley; Sandeep Vaidya; Nghia J Vo
Journal:  Pediatr Radiol       Date:  2013-01-16

8.  CIRSE vascular closure device registry.

Authors:  Jim A Reekers; Stefan Müller-Hülsbeck; Martin Libicher; Eli Atar; Jens Trentmann; Pierre Goffette; Jan Borggrefe; Kamil Zeleňák; Pieter Hooijboer; Anna-Maria Belli
Journal:  Cardiovasc Intervent Radiol       Date:  2010-10-28       Impact factor: 2.740

9.  Detailed analysis of puncture site vascular complications in Japanese Registry of Neuroendovascular Therapy (JR-NET) and JR-NET2.

Authors:  Masayuki Sato; Yuji Matsumaru; Nobuyuki Sakai; Shinichi Yoshimura
Journal:  Neurol Med Chir (Tokyo)       Date:  2013-11-20       Impact factor: 1.742

Review 10.  Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis.

Authors:  Jun Jiang; Junjie Zou; Hao Ma; Yuanyong Jiao; Hongyu Yang; Xiwei Zhang; Yi Miao
Journal:  Sci Rep       Date:  2015-09-08       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.