Literature DB >> 8403304

Vascular complications after balloon and new device angioplasty.

J J Popma1, L F Satler, A D Pichard, K M Kent, A Campbell, Y C Chuang, C Clark, A J Merritt, T A Bucher, M B Leon.   

Abstract

BACKGROUND: Despite their potential advantages, new coronary angioplasty devices may be associated with more frequent vascular complications than noted after standard balloon angioplasty, theoretically due to the larger sheaths and prolonged periods of anticoagulation required by some of these devices. This study sought to identify the incidence, predictors, and clinical outcome of vascular complications after new device angioplasty. METHODS AND
RESULTS: The clinical course of 1413 patients was reviewed after balloon or new device angioplasty. Vascular complications were defined as formation of a pseudoaneurysm, arteriovenous fistula, retroperitoneal hematoma, or groin hematoma associated with a > 15-point hematocrit drop or the need for surgical repair. Stepwise logistic regression was used to identify independent predictors for vascular complications. Vascular complications developed after 84 (5.9%) procedures; they occurred more frequently after intracoronary stenting (14.0%) and extraction atherectomy (12.5%) than after balloon angioplasty (3.2%) (odds ratios, 4.86; P < .001, and 4.26, P < .05, respectively). Independent predictors of vascular complications included the use of intraprocedural thrombolytic agents (P < .01), intracoronary stenting (P < .005), or extraction atherectomy (P < .05); high maximum creatinine level (P < .005); low nadir platelet count (P < .001); longer periods of excess anticoagulation (P < .05); and the need for repeat coronary angioplasty (P < .005). Vascular complications were not related to the size of the arterial sheath used.
CONCLUSIONS: Vascular complications developed more frequently after new device angioplasty than after balloon angioplasty, with the risk for vascular complications directly related to the degree of periprocedural anticoagulation.

Entities:  

Mesh:

Year:  1993        PMID: 8403304     DOI: 10.1161/01.cir.88.4.1569

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  31 in total

1.  [Hemostatic closure of arterial puncture site using Angio-Seal after diagnostic heart catheterization or coronary intervention].

Authors:  H Eggebrecht; M Haude; D Baumgart; O Oldenburg; J Herrmann; C Bruch; P Hunold; C Neurohr; C von Birgelen; D Welge; M A Katz; R Erbel
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

2.  The Duett closure device: concept and experimental results.

Authors:  G Gershony; T Jensen
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

Review 3.  Antiplatelet therapy in interventional cardiology: II. Glycoprotein IIb/IIIa inhibitors.

Authors:  F H Jafary; C D Kimmelstiel
Journal:  J Thromb Thrombolysis       Date:  2000-02       Impact factor: 2.300

4.  Two hour ambulation after coronary angioplasty and stenting with 6 F guiding catheters and low dose heparin.

Authors:  K T Koch; J J Piek; R J de Winter; K Mulder; C E Schotborgh; J G Tijssen; K I Lie
Journal:  Heart       Date:  1999-01       Impact factor: 5.994

Review 5.  Efficacy and safety of the perclose closer s device after neurointerventional procedures: prospective study and literature review.

Authors:  Kamran Khaghany; Firas Al-Ali; Thomas Spigelmoyer; Ron Pimentel; Kurt Wharton
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

6.  Safety and feasibility of a novel vascular closure device in neurointerventional procedures.

Authors:  Ammar Taha; Ellen K Walsh; Kathryn A Wright; Iftikhar Ahmed; Nucharin Supakul; Eric E Awwad; Juan G Tejada
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

7.  Angio-Seal™ Evolution™ versus Manual Compression for Common Femoral Artery Puncture in Neurovascular Diagnostic Angiography : A Prospective, Non-Randomized Study.

Authors:  Joonho Chung; Dong Woo Lee; Ok Sim Kwon; Bum-Soo Kim; Yong Sam Shin
Journal:  J Korean Neurosurg Soc       Date:  2011-03-31

8.  Intracoronary stents.

Authors:  N G Uren; N A Chronos
Journal:  BMJ       Date:  1996-10-12

9.  [Percutaneous suture of femoral artery access sites after diagnostic heart catheterization and or coronary intervention. Safety and effectiveness of a new arterial suture technic].

Authors:  U Gerckens; N Cattelaens; R Müller; E G Lampe; E Grube
Journal:  Herz       Date:  1998-02       Impact factor: 1.443

10.  TransRadial Education and Therapeutics (TREAT): shifting the balance of safety and efficacy of antithrombotic agents in percutaneous coronary intervention: a report from the Cardiac Safety Research Consortium.

Authors:  Connie N Hess; Sunil V Rao; David F Kong; Julie M Miller; Kevin J Anstrom; Olivier F Bertrand; Jean-Philippe Collet; Mark B Effron; Benjamin C Eloff; Emmanuel O Fadiran; Andrew Farb; Ian C Gilchrist; David R Holmes; Alice K Jacobs; Prashant Kaul; L Kristin Newby; David R Rutledge; Dale R Tavris; Thomas T Tsai; Roseann M White; Eric D Peterson; Mitchell W Krucoff
Journal:  Am Heart J       Date:  2013-03       Impact factor: 4.749

View more