PURPOSE: The aim of this study is to assess and compare the accuracy of two different patient-specific instrumentation (PSI) systems for total knee replacement, both intra-operatively for bone preparation and post-operatively for final component alignment. METHODS:Twenty-five patients were treated according to a computer tomography (CT)-based PSI system (group A) and 25 to a magnetic resonance imaging (MRI)/X-ray-based system (group B). Alignments on the three anatomical planes and resection thickness at the cutting blocks and at the resulting bone cuts were recorded intra-operatively by a standard surgical navigation system. Alignments of the prosthetic components and mechanical axis were also measured post-operatively on radiographs. These measurements at both the femur and tibia were compared with those of the corresponding pre-operative planning, considering discrepancies larger than 3° as outliers. RESULTS: In both groups, the mean absolute differences between pre-operatively planned alignments and corresponding intra- and post-operative measurements ranged from a minimum of 1.2° to a maximum of 2.9° in all three anatomical planes. In both groups and in both femur and tibia, the plane with the smallest percentage of outliers was the coronal, maximum 17%. The comparison between two groups was statistically significant (p = 0.02) in the femoral sagittal plane, where group B showed smaller alignment discrepancies at the cutting blocks. CONCLUSIONS: Both PSI systems showed good alignments in the coronal plane in all stages. For a few measurements, a better performance was observed in the MRI/X-ray-based system than in the CT-based system. LEVEL OF EVIDENCE: I.
RCT Entities:
PURPOSE: The aim of this study is to assess and compare the accuracy of two different patient-specific instrumentation (PSI) systems for total knee replacement, both intra-operatively for bone preparation and post-operatively for final component alignment. METHODS: Twenty-five patients were treated according to a computer tomography (CT)-based PSI system (group A) and 25 to a magnetic resonance imaging (MRI)/X-ray-based system (group B). Alignments on the three anatomical planes and resection thickness at the cutting blocks and at the resulting bone cuts were recorded intra-operatively by a standard surgical navigation system. Alignments of the prosthetic components and mechanical axis were also measured post-operatively on radiographs. These measurements at both the femur and tibia were compared with those of the corresponding pre-operative planning, considering discrepancies larger than 3° as outliers. RESULTS: In both groups, the mean absolute differences between pre-operatively planned alignments and corresponding intra- and post-operative measurements ranged from a minimum of 1.2° to a maximum of 2.9° in all three anatomical planes. In both groups and in both femur and tibia, the plane with the smallest percentage of outliers was the coronal, maximum 17%. The comparison between two groups was statistically significant (p = 0.02) in the femoral sagittal plane, where group B showed smaller alignment discrepancies at the cutting blocks. CONCLUSIONS: Both PSI systems showed good alignments in the coronal plane in all stages. For a few measurements, a better performance was observed in the MRI/X-ray-based system than in the CT-based system. LEVEL OF EVIDENCE: I.
Authors: Ryan M Nunley; Bradley S Ellison; Jinjun Zhu; Erin L Ruh; Stephen M Howell; Robert L Barrack Journal: Clin Orthop Relat Res Date: 2011-12-20 Impact factor: 4.176
Authors: Vincent Y Ng; Jeffrey H DeClaire; Keith R Berend; Bethany C Gulick; Adolph V Lombardi Journal: Clin Orthop Relat Res Date: 2012-01 Impact factor: 4.176
Authors: F Zambianchi; A Colombelli; V Digennaro; A Marcovigi; R Mugnai; F Fiacchi; D Sandoni; A Belluati; F Catani Journal: Knee Surg Sports Traumatol Arthrosc Date: 2015-12-24 Impact factor: 4.342
Authors: Tilman Pfitzner; Matthew P Abdel; Philipp von Roth; Carsten Perka; Hagen Hommel Journal: Clin Orthop Relat Res Date: 2014-07-15 Impact factor: 4.176
Authors: Yadin D Levy; Vincent V G An; Christopher J W Shean; Floris R Groen; Peter M Walker; Warwick J M Bruce Journal: Knee Surg Sports Traumatol Arthrosc Date: 2016-08-04 Impact factor: 4.342
Authors: Martijn G M Schotanus; Elke Thijs; Marion Heijmans; Rein Vos; Nanne P Kort Journal: Knee Surg Sports Traumatol Arthrosc Date: 2017-07-11 Impact factor: 4.342